PV1-F Solar Cable for Photovoltaic DC Connections

XWA Power & Cable | Special Cables

PV1-F solar cable connects DC circuits within photovoltaic installations. Flexible tinned copper, cross-linked insulation and an outer sheath support outdoor PV wiring and compact equipment connections.

Rated voltage: 0.6/1 kV AC. DC maximum: 1.8 kV.

Solar cable available from stock. Single-core project sizes include 2.5, 4, 6, 10, 16, 25 and 35 mm². Required quantities and the selected construction define the order.

Solar cable samples showing stranded conductors, insulation and outer coverings.
Solar DC Cable Construction.

PV1-F conductor, insulation and sheath

The single-core construction keeps the flexible conductor inside two distinct protective layers. Tinned copper supports the termination interface, while insulation and the sheath each contribute to the cable system selected for outdoor PV service.

LayerReference construction
ConductorClass 5 flexible tinned copper
InsulationCross-linked halogen-free compound
SheathCross-linked protective compound
Core layoutSingle-core version covered by the dimensional table
Schematic showing a flexible conductor, insulation and an outer sheath.
Solar Cable Layer Schematic.

PV1-F solar cable technical data

Rated voltage U0/U: 0.6/1 kV AC. DC maximum: 1.8 kV. The DC maximum and the rated operating voltage are separate specification fields.

Conductor area (mm²)Approx. conductor OD (mm)Approx. cable OD (mm)Approx. mass (kg/km)Max. conductor resistance at 20°C (Ω/km)Current at 60°C, single cable in air (A)
1.51.604.63113.730
2.52.025.1428.2141
42.595.9615.0955
63.176.6833.3970
104.107.61251.9598
165.509.21881.24132
256.7010.62800.795176
358.2012.23800.565218

Current values describe a single cable in air at 60°C. Grouping, enclosure, installation temperature and the circuit voltage drop affect the installed selection.

Twin PV1-F construction

The twin arrangement keeps two individually insulated conductors together for the DC route. Its cable dimensions, mass and thermal behaviour differ from the single-core version.

Cores × area (mm²)Conductor OD (mm)Cable dimensions (mm)Mass (kg/km)Max. R20 (Ω/km)Current at 60°C (A)
2 × 42.595.7 × 11.71245.0944
2 × 63.176.4 × 13.11693.3957

Materials and operating characteristics

ParameterSelected PV1-F construction
ConductorClass 5 tinned annealed stranded copper
Insulation and outer sheathLow-smoke, halogen-free, electron-beam cross-linked XLPO
Working temperature−40°C to +90°C
Short-circuit temperature200°C for a maximum of 5 seconds
Minimum bending radiusStatic: 4 × cable diameter; flexing: 5 × cable diameter
Mechanical pulling figure50 N/mm² of conductor cross-section

Single-core and twin versions retain their own dimensional schedules. Terminals, cable entries and seals are selected for the actual conductor size and finished cable dimensions.

Module strings, equipment entries and connector fit

PV wiring brings module strings to their collection and conversion equipment. Cable support, strain relief and routing protect the connection as the installation experiences weather and thermal movement.

We would treat the connector and cable as a matched interface. Conductor area determines the terminal crimp range, while the outside diameter determines the cable-entry seal. A connector that fits one cable size is not automatically a complete match for another sheath diameter.

Concept schematic of conductor crimp range and cable-entry seal matching.
PV Cable Connector Interface.

Solar connector options can be discussed alongside the cable order. The connector manufacturer and interface are specified for the intended system; a familiar connector shape alone does not establish cross-brand compatibility.

PV1-F, H1Z2Z2-K and additional solar configurations

ConfigurationProduct distinction
PV1-FLegacy photovoltaic cable designation; selected construction and rating specified separately.
H1Z2Z2-KPhotovoltaic designation associated with EN 50618; separate electrical and construction specification.
Twin-core DC cable2 × 4, 2 × 6 and 2 × 10 mm² configurations in the supplied product schedule.
Armoured twin-core DC cable2 × 4 and 2 × 6 mm² configurations, requiring their own armour and installation specification.

The twin-core and armoured options form separate DC cable constructions, rather than automatic extensions of the single-core PV1-F or H1Z2Z2-K standard designation.

Explore the existing H1Z2Z2-K solar cable page and our cable factory.

PV1-F product questions

Is solar cable available from stock?

Yes. XWA offers solar cable from stock. The selected model, size, colour and required length define the supply discussion.

Are PV1-F and H1Z2Z2-K interchangeable?

They are separate designations. A replacement follows the project specification, rated voltage and matching cable documentation.

Can a solar cable order include connectors?

Connector options can be discussed with the cable requirement. Conductor area, cable diameter and the specified mating interface determine the assembly.

Discuss solar cable supply with XWA

Send your PV1-F or H1Z2Z2-K cable schedule, required lengths and connector details. Our team can discuss the stock cable options and the configuration suited to your PV connection.

    Get a Free Quote in 24 Hours

    Email*:

    Name*:

    Your Country:

    Tel*:

    Your requirements*: