كابل التعدين SHD-GC

قوة XWA & كابل | نماذج الكابلات المطاطية

SHD-GC for shielded trailing power for mobile mining plant

Voltage class shown: 5 كيلو فولت تيار متردد (5,000 V)

SHD-GC cable is a shielded mining trailing cable with flexible power cores, grounding conductors and a ground-check conductor. Its screened power-core construction suits equipment connections where voltage control and ground monitoring must work together.

The reference design on this page is a three-power-core, 5 بناء كيلو فولت. Each phase includes the appropriate conductor screen, EPR insulation and flexible metallic shielding arrangement. Different SHD-GC voltage classes have different insulation and dimensional schedules.

SHD-GC mining cable sample with exposed copper conductors and a black outer sheath
SHD-GC mining cable sample.

5 kV reference construction

SHD-GC conductor and layer arrangement

5 kV shielded example cross-section showing 3 screened power cores, 2 grounding conductors, 1 insulated check core, Reinforced jacket
SHD-GC construction schematic.
عنصربناء
موصل المرحلةThree flexible rope-lay copper conductors.
Conductor screen and insulationSemiconductive conductor screen followed by EPR insulation.
Insulation shieldingFlexible copper/textile braid shielding around each insulated phase in the reference design.
Grounding and checkTwo grounding conductors plus a separately insulated ground-check core.
الحماية الخارجيةReinforced heavy-duty jacket enclosing the complete assembly.

ICEA S-75-381 / NEMA WC 58 provides the mining-cable construction and test framework. The cited dimensional group is specifically 5 كيلو فولت, 100% مستوى العزل, grounded service. Other voltage groups require their own design tables.

SHD-GC reference sizes and technical data

المعلمة الكهربائيةمواصفة
الجهد المقنن5 كيلو فولت تيار متردد (5,000 V)
اتفاقية التقييممختارة 5 بناء كيلو فولت; 100% مستوى العزل, grounded service
مرجع معيار البناءICEA S-75-381 / NEMA WC 58
الترتيب الأساسيThree screened power cores, two grounding conductors and one ground-check conductor.
Power coresأرضي (الفريق العامل المخصص)Check (الفريق العامل المخصص)العزل (مم)سترة (مم)ل (مم)كتلة (كجم/كم)حاضِر (أ)
3 × 1/0 الفريق العامل المخصص482.85.652.34530211
3 × 2/0 الفريق العامل المخصص382.85.655.15315243
3 × 4/0 الفريق العامل المخصص182.86.068.87380321

مختارة 5 kV reference construction: three power cores, two grounding conductors and one check core; 100% مستوى العزل, grounded. Reference current values use 90°C conductor and 40°C ambient air under ICEA S-75-381/NEMA WC 58; reel layers and installation conditions require correction.

Shield termination belongs in the machine connection design

Power shovels, draglines and other relocatable mining plant place combined electrical and mechanical demands on their supply cable. The power-core shields, grounding conductors, monitor loop and coupler must remain coordinated when cable is extended, repaired or replaced.

We would treat the coupling arrangement as part of the cable requirement from the outset. A heavier jacket can improve mechanical protection, but it does not address a mismatched shield connection or an unsuitable ground-check termination.

SHD-GC and related rubber cable types

عائلة الكابلالتمييز ذات الصلة
اكتب جي-جي سيGround-check cable with a different power-core screening arrangement; the selected reference is 2 كيلو فولت.
SHD-GC 5 كيلو فولتScreened power cores and monitoring conductors for the defined 5 kV duty.
SHD-GC at other voltagesSeparate insulation, شاشة, diameter and coupling requirements; retain the exact voltage class.

For the wider context of SHD-GC applications, استكشاف نطاق الكابلات المطاطية, NSSHÖU heavy-duty cable ولدينا معلومات المصنع XWA.

SHD-GC cable questions

What distinguishes SHD-GC from G-GC?

SHD-GC adds a shielded power-core construction. Both the shield system and the required voltage class affect dimensions, grounding and termination design.

هل أ 5 kV table apply to 8 كيلو فولت أو 15 كابل كيلو فولت?

لا. Each voltage class requires the corresponding insulation and screen design. The reference dimensions on this page describe only the stated 5 بناء كيلو فولت.

Is the ground-check conductor the same as a grounding conductor?

The check core is used in the monitoring loop. The grounding conductors and the shield-grounding arrangement carry their specified protective duties.

Discuss a SHD-GC cable project with XWA

Send your SHD-GC cable schedule or equipment specification, الطول المطلوب والوجهة ل info@xwacable.com. يعد الرسم أو التعيين الحالي نقطة بداية عملية لمناقشة المنتج والاقتباس.

لسياق المعايير, انظر المرجع الفني الرسمي.

    احصل على عرض أسعار مجاني في 24 ساعات

    بريد إلكتروني*:

    اسم*:

    بلدك:

    الهاتف*:

    متطلباتك*: