High Voltage 2XS(فلوريدا)2والكابل
2XS(فلوريدا)2والكابل is a single-core high-voltage power cable with a copper conductor, العزل XLPE, شاشة معدنية, longitudinal and radial water-blocking layers, and a polyethylene outer sheath.
The designation is used for underground and ducted high-voltage distribution and transmission routes where IEC 60840-type construction, water blocking and PE sheath performance are part of the project specification. Common voltage classes include 26/45 (52) كيلو فولت, 36/60 (72.5) كيلو فولت, 64/110 (123) كيلو فولت و 76/132 (145) كيلو فولت.
XWA supplies project-configured 2XS(فلوريدا)2Y high-voltage cable according to the confirmed voltage class, حجم الموصل, screen section, مادة غمد, متطلبات الاختبار, drum length and export documentation scope.

بناء
موصل:
فصل 2 موصل النحاس الذين تقطعت بهم السبل; watertight conductor option where specified
العزل:
XLPE insulation with extruded semiconductive conductor and insulation screens
شاشة معدنية:
Copper wires with equalising tape and water-swelling tape around the screen area
Radial Barrier:
Longitudinal aluminium copolymer laminated tape bonded to the PE sheath for radial water blocking
صفات
Voltage Classes:
26/45 (52) كيلو فولت, 36/60 (72.5) كيلو فولت, 64/110 (123) كيلو فولت و 76/132 (145) كيلو فولت
الغلاف الخارجي:
HDPE or MDPE outer sheath, normally black; semiconductive outer layer by project requirement
تثبيت:
Fixed high-voltage installation in ground, القنوات, trenches, substations and utility network routes
المعايير:
Common references include IEC 60840 واللجنة الانتخابية المستقلة 60228. Standard reference is not a certification or project approval claim.
2XS(فلوريدا)2Y High Voltage Cable for Underground Networks
XWA manufactures high-voltage XLPE cable configurations for utility networks, المحطات الفرعية, renewable energy grid connections and industrial power systems.
2XS(فلوريدا)2Y Cable Technical Data
Recommended Reference Data: 2XS(فلوريدا)2Y is normally a single-core high-voltage cable. The table below is a planning reference for copper-conductor 110 كيلو فولت و 132 kV class designs, not a guaranteed XWA datasheet.
Final cable dimensions, بناء الموصل, screen section, سمك غمد, induced-voltage design and current-carrying capacity depend on the approved project datasheet, bonding method, route spacing, عمق الدفن, درجة الحرارة المحيطة, soil thermal resistivity and installation standard.
Voltage and Size Coverage
| فئة الجهد | Typical route | Cross-section coverage | Planning note |
|---|---|---|---|
| 26/45 (52) كيلو فولت | 45 kV class underground HV routes | 150-3000 mm2 reference range | اللجنة الانتخابية المستقلة 60840 HV cable scope |
| 36/60 (72.5) كيلو فولت | 60 كيلو فولت / 66 kV utility distribution | 185-3000 mm2 reference range | Often specified for sub-transmission feeders |
| 64/110 (123) كيلو فولت | 110 kV grid and industrial feeders | 150-3000 mm2 reference range | Core page intent for 110kV 2XS(فلوريدا)2Y |
| 76/132 (145) كيلو فولت | 132 kV transmission and substation routes | 185-3000 mm2 reference range | Core page intent for 132kV 2XS(فلوريدا)2Y |
Construction Matrix
| Layer | Typical material | Function |
|---|---|---|
| موصل | نحاس, فصل 2 الذين تقطعت بهم السبل | Optional water-tight conductor when specified |
| شاشة الموصل | Extruded semiconductive layer | Applied as part of the triple-extruded insulation system |
| العزل | XLPE | 90 C normal conductor temperature reference |
| Insulation screen | Extruded semiconductive layer | Matched to the insulation system |
| Wrapping | Semiconductive water-swelling tape | Longitudinal water blocking around the screen area |
| شاشة معدنية | Copper wires and equalising tape | Screen section follows fault-current design |
| Radial barrier | Aluminium copolymer laminated tape | The FL element provides radial water-blocking logic |
| Outer sheath | HDPE or MDPE | Black sheath; semiconductive layer optional |
Selected 110 كيلو فولت و 132 kV Reference Rows
| فئة الجهد | حجم الكابل (مم2) | الأعلى. DC resistance at 20 ج (أوم / كم) | Nominal XLPE insulation (مم) | Typical screen section (مم2) | Use note |
|---|---|---|---|---|---|
| 64/110 (123) كيلو فولت | 1 س 150 | 0.124 | 16.0 | 95 | Typical entry size for 110 kV class |
| 64/110 (123) كيلو فولت | 1 س 300 | 0.0601 | 16.0 | 95 أو 120 | Common 110 kV project size |
| 64/110 (123) كيلو فولت | 1 س 630 | 0.0283 | 16.0 | 95 أو 120 | High-capacity underground feeder |
| 64/110 (123) كيلو فولت | 1 س 1000 | 0.0176 | 16.0 | 120 | High-current route, bonding review required |
| 76/132 (145) كيلو فولت | 1 س 185 | 0.0991 | 16.5 | 95 أو 120 | 132 kV entry project range |
| 76/132 (145) كيلو فولت | 1 س 300 | 0.0601 | 16.5 | 95 أو 120 | Common 132 kV project size |
| 76/132 (145) كيلو فولت | 1 س 630 | 0.0283 | 16.5 | 95 أو 120 | High-capacity 132 kV feeder |
| 76/132 (145) كيلو فولت | 1 س 1000 | 0.0176 | 16.5 | 120 | Large-section transmission route |
2XS(فلوريدا)2Y Cable Construction
2XS(فلوريدا)2Y uses a copper conductor with an extruded conductor screen, XLPE insulation and extruded insulation screen. The metallic screen uses copper wires and an equalising tape, with semiconductive water-swelling tape placed around the screen area.
The `(فلوريدا)` part is the key distinction from simpler PE-sheathed HV cable. It indicates a water-blocked design with longitudinal water blocking and a radial barrier formed by an aluminium copolymer laminated tape bonded to the polyethylene sheath.
This construction is normally single-core. Three-core high-voltage cable is not treated as the standard form for this designation because electrical stress control, نصف قطر الانحناء, screen bonding and installation handling are different.
Applications for 2XS(فلوريدا)2Y High Voltage Cable
2XS(فلوريدا)2Y Cable is used in buried high-voltage networks, duct routes, اتصالات المحطات الفرعية, renewable-energy grid connections, industrial incoming feeders and utility transmission circuits where PE-sheathed water-blocked HV cable is specified.
The design is especially relevant where moisture exposure, long underground routes, joint bays and sheath integrity are important parts of the cable system. Cable accessories, bonding design and route thermal calculation remain part of the complete HV system design.
للأنفاق, indoor termination sections or routes requiring low-smoke zero-halogen sheath behaviour, the related `2XS(فلوريدا)H` construction may be reviewed instead of a PE-sheathed `2Y` design.
2XS(فلوريدا)2Y vs A2XS(فلوريدا)2Y and 2XS(ف)2Y
2XS(فلوريدا)2Y and A2XS(فلوريدا)2Y share the same high-voltage water-blocked cable logic, لكن مادة الموصل مختلفة. 2XS(فلوريدا)2Y uses copper, while A2XS(فلوريدا)2Y uses aluminium.
2XS(ف)2Y is not the same as 2XS(فلوريدا)2Y. The `(ف)` designation is associated with longitudinal water blocking, while `(فلوريدا)` adds the laminated radial barrier concept. This difference matters for wet underground routes and sheath-damage risk.
N2XS2Y and N2XSY pages remain medium-voltage designations. The 2XS(فلوريدا)2Y page targets high-voltage IEC 60840-type project intent and should not compete with the medium-voltage cluster.
| نموذج | التمييز الرئيسي | Page role |
|---|---|---|
| 2XS(فلوريدا)2Y | موصل النحاس, XLPE, water-blocked screen area, laminated radial barrier, غمد بي | هذه الصفحة |
| A2XS(فلوريدا)2Y | Aluminium conductor version | Next companion HV page |
| 2XS(ف)2Y | Copper conductor with longitudinal water blocking, without the same FL radial-barrier meaning | Separate water-blocked variant |
| 2XS(فلوريدا)ح | LSZH outer sheath direction | Indoor or low-smoke route comparison |
اختبار, المستندات وتعبئة الصادرات
High-voltage 2XS(فلوريدا)2Y cable documentation can include the approved datasheet, conductor resistance record, voltage test record, partial-discharge test record, اختبار غمد, فحص الأبعاد, جدول الطبل, قائمة التعبئة وصور المنتج.
Type-test evidence, third-party inspection and project-specific test documentation are handled according to the exact voltage class, cable construction and contract requirement. No third-party certification, grid approval or project reference is implied unless separately verified.
Export packing is planned by cable weight, الحد الأقصى لقطر الطبل, transport route, lifting method and container loading limit. Large-section 110 كيلو فولت و 132 kV single-core cables require drum-length planning before production.
2XS(فلوريدا)2Y Cable FAQs
What is 2XS(فلوريدا)2والكابل?
2XS(فلوريدا)2Y Cable is a single-core copper-conductor high-voltage XLPE cable with metallic screen, longitudinal water blocking, laminated radial water barrier and polyethylene outer sheath. It is used for fixed HV underground and ducted cable systems.
What voltage classes are common for 2XS(فلوريدا)2والكابل?
تشمل فئات جهد المشروع الشائعة 26/45 (52) كيلو فولت, 36/60 (72.5) كيلو فولت, 64/110 (123) كيلو فولت و 76/132 (145) كيلو فولت. The project specification defines the exact Uo/U and Um rating.
What does FL mean in 2XS(فلوريدا)2والكابل?
The `(فلوريدا)` element indicates water-blocking construction with longitudinal water-blocking layers and a laminated radial barrier bonded to the polyethylene sheath. It is a key distinction from simpler PE-sheathed HV cable.
Is 2XS(فلوريدا)2Y a single-core or three-core cable?
2XS(فلوريدا)2Y is normally a single-core HV cable. Three-core high-voltage designs require a separate review because the construction, مُكَمِّلات, installation handling and electrical design are different.
What is the difference between 2XS(فلوريدا)2Y and A2XS(فلوريدا)2Y?
2XS(فلوريدا)2Y uses a copper conductor. A2XS(فلوريدا)2Y uses an aluminium conductor. The conductor material changes resistance, وزن, size selection, termination design and short-circuit performance.
What is the difference between 2XS(فلوريدا)2Y and 2XS(ف)2Y?
2XS(ف)2Y is associated with longitudinal water blocking. 2XS(فلوريدا)2Y adds the laminated radial barrier concept, so the two designations should not be treated as interchangeable in wet underground routes.
Where is 2XS(فلوريدا)2Y Cable used?
2XS(فلوريدا)2Y is used in underground high-voltage feeders, utility grids, المحطات الفرعية, renewable-energy grid connections, industrial incoming supplies and ducted transmission routes where water-blocked PE-sheathed HV cable is specified.
What standards are used for 2XS(فلوريدا)2والكابل?
اللجنة الانتخابية المستقلة 60840 is the common reference for extruded-insulation power cables above 30 kV and up to 150 كيلو فولت. اللجنة الانتخابية المستقلة 60228 is commonly used for conductor class reference. Standard mention does not mean third-party certification or grid approval.
Can 2XS(فلوريدا)2Y Cable be supplied with MDPE or HDPE sheath?
HDPE and MDPE sheath directions are both used in project specifications. The sheath choice depends on route conditions, mechanical exposure, installation handling and the approved datasheet.
What information is needed for a 2XS(فلوريدا)2Y Cable quotation?
XWA confirms 2XS(فلوريدا)2Y Cable based on voltage class, حجم الموصل, screen section, مادة غمد, حالة الطريق, معيار, كمية, طول الطبل, destination country and required test documents.

كابل الطاقة عالي الجهد
High-voltage XLPE cable systems for transmission, substations and utility network routes.

110كابل كيلو فولت
High-voltage cable page for 110kV underground and substation cable systems.