كابل XLPE/SWA/PVC

XLPE/SWA/PVC cable combines XLPE insulation, steel wire armour and a PVC outer sheath for fixed power distribution. The construction can use copper or aluminium conductors, with insulation and electrical screens selected for the rated voltage.

For fixed industrial and suitable underground routes, this construction balances integral mechanical protection with the space and handling needs of an armoured cable. Outside diameter, mass and termination hardware matter alongside conductor size. قوة XWA & Cable manufactures power cables in China; explore our factory and production information for the manufacturing processes behind the range.

Orange-sheathed four-core copper cable sample marked XLPE/SWA/PVC 0.6/1 kV 4X25 with exposed wire armour
Real sample marked XLPE/SWA/PVC 0.6/1 kV 4X25; other voltage designs have different layer arrangements.

XLPE/SWA/PVC for Your Project

Send the voltage, مادة موصل, core size and required length, or attach your existing cable schedule.

طلب عرض أسعار

XLPE Insulation, Steel Wire Armour and PVC Sheath

In CU/XLPE/PVC/SWA/PVC, the layers run from copper conductor through XLPE insulation, PVC bedding and steel wire armour to the PVC outer sheath. Fillers support the assembled cores, while screened MV designs add the required electrical layers.

عنصرFunction in the cableSpecification that changes the design
موصل النحاس أو الألومنيوميحمل تيار الحملمادة, منطقة, conductor class and core arrangement
العزل XLPEProvides electrical insulation around each phase conductorRated voltage and declared insulation thickness
شاشات كهربائية, حيثما كان ذلك مطلوباControl the electric field and provide the specified metallic-screen functionSemiconductive layers, screen material, area and fault duty
الفراش أو الغمد الداخليSeparates the laid-up cores and armourمادة, thickness and compatibility with the assembly
درع من الأسلاك الفولاذيةAdds a layer of mechanical protectionWire diameter, التغطية, corrosion protection and termination arrangement
غلاف خارجي من مادة PVCCovers the armoured assemblyمُجَمَّع, thickness and declared environmental or fire performance

What Changes Between Voltage Classes

Steel wire armour provides mechanical protection across different voltage classes. The insulation and screening system is designed for the rated voltage.

Construction groupRepresentative configurationProject role
Low-voltage powerMulticore CU or AL / XLPE / الفراش / سوا / بولي كلوريد الفينيل; 0.6/1 kV is one common exampleFixed plant feeders, distribution circuits and protected outdoor routes
توزيع الجهد المتوسطThree screened XLPE cores, شاشات معدنية, inner sheath, SWA and PVC; examples include 6/10 و 12/20 kV designsIndustrial intake, transformer feeders and distribution networks
High-voltage and special armoured systemsFull project-specific electrical, metallic-sheath, armour and outer-protection designTransmission and special-service routes requiring a separate cable-system review

In screened MV cable, semiconductive layers control the electric field and the metallic screen performs its specified electrical duty. These sit inside the bedding, armour and outer sheath.

High-voltage armoured systems require a dedicated insulation, الفحص, sheath and armour design. Specialised submarine systems also address marine installation loads, moisture protection and accessories.

نهاية مقطوعة لكابل نحاسي رباعي النواة يظهر عزلًا ملونًا للقلب وحلقة من الأسلاك المدرعة
مقطع عرضي للكابل رباعي النواة مع موصلات نحاسية ودرع من أسلاك الفولاذ.

Armour selection for single-core AC circuits

Steel is ferromagnetic. Applying ordinary steel wire armour around a single AC phase can introduce additional magnetic losses and heating. Single-core AC power cables commonly use non-magnetic armour such as aluminium wire armour (أوا), while SWA is common around multicore assemblies.

Conductor and armour materials are separate choices: a copper conductor can have aluminium wire armour. Special HV, DC and unusual armour arrangements are assessed for their losses, bonding and mechanical duty.

Technical Scope and Standards

Design itemLow-voltage exampleScreened medium-voltage example
الفولطية U0/U0.6/1 kV reference construction6/10 أو 12/20 kV reference construction; system requirements govern selection
الموصلاتالنحاس أو الألومنيوم; conductor class declared on the datasheetالنحاس أو الألومنيوم; conductor and metallic-screen areas specified separately
نظام العزلXLPE insulated cores with the declared bedding arrangementXLPE with semiconductive screens and the declared metallic screen
Standard contextاللجنة الانتخابية المستقلة 60502-1 حيث المحدداللجنة الانتخابية المستقلة 60502-2 حيث المحدد
Final dimensional dataالعد الأساسي, insulation and sheath thickness, armour wires, OD and massThe same items plus screened-core and accessory interface dimensions
التصنيف الحاليInstallation-specific calculation or matched datasheet conditionsتثبيت, screen/armour losses, bonding and thermal conditions

The configurations shown illustrate the construction family. الأبعاد النهائية, ratings and supply scope follow the agreed XWA datasheet for the selected voltage, core arrangement and materials.

اللجنة الانتخابية المستقلة 60228 addresses conductors; اللجنة الانتخابية المستقلة 60502-1 واللجنة الانتخابية المستقلة 60502-2 cover their respective LV and MV power-cable ranges. اللجنة الانتخابية المستقلة 60840 provides the framework for higher-voltage systems within its scope. ال نطاق النشر الرسمي describes the MV standard coverage.

Underground and Industrial Route Conditions

SWA provides integral mechanical protection for industrial feeders and suitable underground routes. Burial design includes bedding preparation, ground conditions, safe pulling and the specified minimum bending radius.

Sheath selection follows the route: standard PVC, low-smoke halogen-free compounds and materials for chemical or prolonged water exposure have different properties and test requirements.

Glands match the armour dimensions and overall cable diameter. Where armour serves as a protective conductor, fault-current capacity and electrical continuity are assessed for the complete connection. See the MV steel wire armour construction guide for details.

Find the Matching Cable Range

Project requirementRelated XWA rangeRelationship to this structure family
Fixed low-voltage power circuitsكابل الجهد المنخفضVoltage-class context; includes constructions other than SWA
Screened distribution feedersكابل الجهد المتوسطScreened electrical designs; armour is specified separately
Transmission-system requirementsكابل الجهد العاليFull electrical, sheath and accessory system definition
An aluminium phase conductorAluminium CableConductor-material range; aluminium conductor does not mean aluminium armour

يستكشف أنواع ونماذج الكابلات for related voltage classes, named cable models and conductor families.

Project Lengths and Factory Support

XWA supports power cable manufacturing to customer drawings and cable schedules. The agreed construction defines the electrical specification, while quantities and drum lengths set the delivery arrangement.

For large-section cable, the delivery arrangement matters at installation as well as in transit. Finished diameter and cable mass help determine drum selection, lifting equipment and pulling arrangements. Drum barrel dimensions must accommodate the agreed bending limit, and gross handling weight includes the drum as well as the cable.

بكرات كابلات فولاذية كبيرة مع كابل أسود ملفوف على أرضية المصنع
بكرات فولاذية مزودة بكابل ملفوف للتعامل وتخطيط الأسطوانة.

Have a cable schedule or a route requirement to discuss? اتصال info@xwacable.com / واتساب. Manufacturing scope, inspection documents and delivery arrangements are confirmed against the requested construction.

XLPE/SWA/PVC Cable Questions

What does XLPE/SWA/PVC mean?

يحدد XLPE العزل, SWA the steel wire armour and PVC the outer sheath. مادة موصلة, العد الأساسي, rated voltage and any electrical screens complete the specification.

Is XLPE/SWA/PVC cable only low voltage?

The construction is used in LV and screened MV designs. Higher-voltage armoured cables use a dedicated cable-system design, including voltage-appropriate insulation, screens and sheath arrangements.

Can a single-core AC cable use ordinary steel wire armour?

Ordinary ferromagnetic steel armour around a single AC phase can increase losses and heating. Non-magnetic armour such as AWA is commonly used; special steel arrangements require a loss and bonding assessment.

Does SWA make a cable waterproof or fire resistant?

SWA provides mechanical protection. Waterproofing, fire behaviour and continued circuit operation during fire each require the relevant materials, construction and tests.

    احصل على عرض أسعار مجاني في 24 ساعات

    بريد إلكتروني*:

    اسم*:

    بلدك:

    الهاتف*:

    متطلباتك*: