SHD-GC for shielded trailing power for mobile mining plant

Voltage class shown: 5 kV CA (5,000 V)

SHD-GC cable is a shielded mining trailing cable with flexible power cores, grounding conductors and a ground-check conductor. Its screened power-core construction suits equipment connections where voltage control and ground monitoring must work together.

The reference design on this page is a three-power-core, 5 costruzione kV. Each phase includes the appropriate conductor screen, EPR insulation and flexible metallic shielding arrangement. Different SHD-GC voltage classes have different insulation and dimensional schedules.

SHD-GC mining cable sample with exposed copper conductors and a black outer sheath
SHD-GC mining cable sample.

5 kV reference construction

SHD-GC conductor and layer arrangement

5 Esempio di sezione trasversale schermata kV mostrata 3 nuclei di alimentazione schermati, 2 conduttori di terra, 1 nucleo di controllo isolato, Giacca rinforzata
SHD-GC construction schematic.
ComponenteCostruzione
Conduttore di faseThree flexible rope-lay copper conductors.
Conductor screen and insulationSemiconductive conductor screen followed by EPR insulation.
Insulation shieldingFlexible copper/textile braid shielding around each insulated phase in the reference design.
Grounding and checkTwo grounding conductors plus a separately insulated ground-check core.
Protezione esternaReinforced heavy-duty jacket enclosing the complete assembly.

ICEA S-75-381 / NESSUN WC 58 provides the mining-cable construction and test framework. The cited dimensional group is specifically 5 kV, 100% livello di isolamento, grounded service. Other voltage groups require their own design tables.

SHD-GC reference sizes and technical data

Parametro elettricoSpecifica
Tensione nominale5 kV CA (5,000 V)
Convenzione di valutazioneSelezionato 5 costruzione kV; 100% livello di isolamento, grounded service
Riferimento normativo costruttivoICEA S-75-381 / NESSUN WC 58
Disposizione centraleThree screened power cores, two grounding conductors and one ground-check conductor.
Power coresTerra (AWG)Check (AWG)Isolamento (mm)Giacca (mm)DI (mm)Massa (kg/km)Attuale (UN)
3 × 1/0 AWG482.85.652.34530211
3 × 2/0 AWG382.85.655.15315243
3 × 4/0 AWG182.86.068.87380321

Selezionato 5 kV reference construction: three power cores, two grounding conductors and one check core; 100% livello di isolamento, grounded. Reference current values use 90°C conductor and 40°C ambient air under ICEA S-75-381/NEMA WC 58; reel layers and installation conditions require correction.

Shield termination belongs in the machine connection design

Power shovels, draglines and other relocatable mining plant place combined electrical and mechanical demands on their supply cable. The power-core shields, conduttori di terra, monitor loop and coupler must remain coordinated when cable is extended, repaired or replaced.

We would treat the coupling arrangement as part of the cable requirement from the outset. A heavier jacket can improve mechanical protection, but it does not address a mismatched shield connection or an unsuitable ground-check termination.

SHD-GC and related rubber cable types

Famiglia di caviDistinzione rilevante
Digitare G-GCGround-check cable with a different power-core screening arrangement; the selected reference is 2 kV.
SHD-GC 5 kVScreened power cores and monitoring conductors for the defined 5 kV duty.
SHD-GC at other voltagesSeparate insulation, schermo, diameter and coupling requirements; retain the exact voltage class.

For the wider context of SHD-GC applications, esplorare il gamma di cavi in ​​gomma, NSSHÖU heavy-duty cable e il nostro Informazioni sulla fabbrica XWA.

SHD-GC cable questions

What distinguishes SHD-GC from G-GC?

SHD-GC adds a shielded power-core construction. Both the shield system and the required voltage class affect dimensions, grounding and termination design.

Fa a 5 kV table apply to 8 kV o 15 cavo kV?

NO. Each voltage class requires the corresponding insulation and screen design. The reference dimensions on this page describe only the stated 5 costruzione kV.

Is the ground-check conductor the same as a grounding conductor?

The check core is used in the monitoring loop. The grounding conductors and the shield-grounding arrangement carry their specified protective duties.

Discuss a SHD-GC cable project with XWA

Send your SHD-GC cable schedule or equipment specification, lunghezza richiesta e destinazione info@xwacable.com. Un disegno o una designazione esistente è un punto di partenza pratico per una discussione sul prodotto e sull'offerta.

Per il contesto degli standard, vedere il riferimento tecnico ufficiale.

    Ottieni un preventivo gratuito 24 Ore

    E-mail*:

    Nome*:

    Il tuo Paese:

    Telefono*:

    Le tue esigenze*: