Cavo N2XY

Cavo N2XY

Cavo N2XY is a 0.6/1 kV copper power cable with XLPE insulation and a PVC outer sheath. It is designed for fixed low-voltage power distribution in industrial plants, edifici commerciali, infrastrutture, utility systems, cable ducts and protected underground routes.

The cable is available in single-core and multicore constructions. N2XY-J versions include a green/yellow protective conductor, while N2XY-O versions do not. XLPE insulation provides reliable thermal performance, and the PVC sheath gives practical protection for general indoor and outdoor fixed installations.

N2XY NA2XY

COSTRUZIONE

Conduttore:

Conduttore in rame, normally IEC 60228 Classe 1 o Classe 2 according to size and project specification

Isolamento:

Polietilene reticolato (XLPE); insulation thickness must follow the ordered voltage and applicable standard

Guaina esterna:

Guaina esterna in PVC, commonly black; colour, UV performance and flame requirements must be confirmed

Identificazione del nucleo:

N2XY-J includes a green/yellow protective conductor; N2XY-O does not. Confirm core colours and marking against the destination standard.

CARATTERISTICHE

Tensione nominale Uo/U:

0.6/1 kV

Conductor Temperature:

Maximum conductor temperature: 90°C under normal operation

Installazione:

Fixed installation in cable trays, condotti, condotti, buildings and protected outdoor or underground routes

NORME:

DIN VDE 0276-603 / HD 603, CEI 60502-1 e CEI 60228

N2XY Cable for Low-Voltage Power Projects

XWA supplies N2XY power cable in single-core and multicore configurations for international low-voltage projects.

N2XY Cable Technical Data

Technical ItemN2XY Cable Specification
Designazione del cavoN2XY-J / N2XY-O
Rated voltage0.6/1 kV
ConduttoreRame, solid or stranded according to cable size
Conductor classCEI 60228 Classe 1 o Classe 2
IsolamentoXLPE (polietilene reticolato)
Guaina esternaPVC, commonly black
Core constructionSingle-core and multicore
Protective conductorIncluded in N2XY-J; not included in N2XY-O
Maximum conductor temperatureCommonly 90°C in normal operation
InstallazioneFixed indoor, all'aperto, condotto, tray and protected underground installation
Common standardsDIN VDE 0276-603 / HD 603, CEI 60502-1, CEI 60228
N2XY cable drum packing reference
Cable drum packing used for power cable transport and storage.

N2XY Cable Applications

N2XY is used for fixed power distribution where a robust XLPE/PVC cable is required. It can be installed on cable trays, in ducts and conduits, inside buildings, in industrial service areas and in protected outdoor routes.

  • Impianti industriali, workshops and process facilities.
  • Commercial buildings, warehouses and utility rooms.
  • Low-voltage distribution boards and equipment connections.
  • Infrastrutture, water-treatment and energy projects.
  • Cable ducts and protected underground power routes.

Because standard N2XY is unarmoured, exposed routes with impact, crushing or excavation risk may require conduit, covers or an armoured cable. It is intended for fixed installation rather than continuous movement or portable equipment.

N2XY vs N2XH and NYY Cable

N2XY, N2XH and NYY are all fixed power cables, but their insulation and sheath materials suit different project requirements. N2XY combines XLPE insulation with a PVC sheath. N2XH uses a halogen-free sheath system, while NYY normally uses PVC for both insulation and sheath.

CaratteristicaN2XYN2XHNYY
IsolamentoXLPEXLPEPVC
Guaina esternaPVCHalogen-free low-smoke compoundPVC
Typical useGeneral fixed power distributionProjects requiring LSZH performanceGeneral PVC power distribution
Normal conductor temperatureCommonly 90°CCommonly 90°CCommonly 70°C
Main selection pointXLPE thermal performance with PVC sheathLow smoke and halogen-free requirementsConventional PVC construction

N2XH is normally selected when low-smoke and halogen-free performance is specified. NYY remains a conventional PVC cable option. The project cable schedule and fire requirements determine which construction is appropriate.

N2XY Cable Performance and Installation

The XLPE insulation used in N2XY cable is commonly designed for a maximum conductor operating temperature of 90°C. This provides a higher thermal rating than conventional PVC-insulated NYY cable. Actual current-carrying capacity still depends on conductor size, metodo di installazione, temperatura ambiente, cable grouping and soil conditions.

The PVC outer sheath offers resistance to normal moisture and general installation conditions. Outdoor versions commonly use a black PVC sheath, with UV resistance and environmental performance defined by the cable specification. Minimum bending radius and pulling force depend on cable diameter and construction.

N2XY can be installed underground when the cable construction and local installation rules allow it. Since it is normally unarmoured, direct-burial routes may require ducts, mechanical covers or another protective system. An armoured power cable is more suitable where integral impact protection is required.

N2XY Cable application in fixed building wiring
Fixed power cable installation in building wiring.

FAQs of XWA N2XY Cable

What does the N2XY cable designation mean?

N2XY is a VDE-style power cable designation. N indicates a cable made to a recognized national standard, 2X indicates XLPE insulation, and Y indicates a PVC outer sheath. The cable normally uses copper conductors and is supplied for fixed low-voltage power distribution.

N2XY-J includes a green/yellow protective conductor. N2XY-O does not include a green/yellow protective conductor. The core identification must match the circuit and installation design.

N2XY is used for fixed power distribution in industrial plants, edifici commerciali, infrastrutture, utilities, cable trays, ducts and protected underground routes. It is not designed as a portable or continuously flexible cable.

SÌ. N2XY can be used in suitable outdoor and underground fixed installations. Because it is normally unarmoured, routes exposed to mechanical damage may need ducts, covers or a separate armoured cable construction.

Both cables normally use copper conductors and XLPE insulation. N2XY has a PVC outer sheath, while N2XH uses a halogen-free low-smoke sheath. N2XH is used where the project requires LSZH fire performance.

N2XY uses XLPE insulation and a PVC sheath. NYY normally uses PVC insulation and a PVC sheath. The XLPE insulation in N2XY commonly supports a 90°C conductor operating temperature, compared with the typical 70°C rating of PVC insulation.

N2XY is commonly rated 0.6/1 kV, with a normal maximum conductor operating temperature of 90°C. Exact installation temperature, short-circuit rating and current capacity depend on the approved cable design and installation conditions.

N2XY Cable uses single-core and multicore constructions, including versions with or without a green/yellow protective conductor. Typical configurations include 1-core, 2-nucleo, 3-nucleo, 4-core and 5-core power cables across a range of conductor sizes.

Cavi N2XOH

Cavo N2XOH

Halogen-free low-smoke power cable for projects that specify an LSZH sheath system.

H07V-K Cable

Cavo H07V-K

Flexible single-core PVC-insulated wire for protected fixed wiring and panel applications.

Casi di studio XWA & Progetti

    Ottieni un preventivo gratuito 24 Ore

    E-mail*:

    Nome*:

    Il tuo Paese:

    Telefono*:

    Le tue esigenze*: