N2XSY Cable

N2XSY Cable is a single-core medium-voltage power cable with a stranded copper conductor, XLPE izolasyonu, copper wire screen and PVC outer sheath.

The designation is used for fixed medium-voltage distribution in transformer stations, switching substations, power plants, industrial networks, renewable-energy collection systems and utility cable routes. Common project voltage classes include 6/10 kV, 8.7/15 kV, 12/20 kV and 18/30 kV under IEC and VDE-oriented specifications.

XWA supplies N2XSY as a project cable configuration where conductor size, copper screen section, voltage class, sheath colour, test documents and export packing are matched to the cable schedule and destination market.

N2XSY Cable single-core medium voltage power cable

YAPI

İletken:

Sınıf 2 stranded copper conductor, round compacted where specified

Yalıtım:

XLPE insulation with inner and outer semiconductive screens

Metalik Ekran:

Copper wire screen with counter helix; screen section selected by fault-current requirement

Dış Kılıf:

PVC outer sheath, commonly red for MV identification; colour and UV requirement follow project specification

ÖZELLİKLER

Voltage Classes:

6/10 kV, 8.7/15 kV, 12/20 kV and 18/30 kV project classes

Conductor Temperature:

XLPE medium-voltage designs commonly use 90°C maximum conductor temperature in normal service

Kurulum:

Fixed installation indoors, outdoors, in ducts and in ground routes with suitable mechanical and thermal design

STANDARTLAR:

Common references include IEC 60502-2, VDE 0276-620, IEC 60228 ve IEC 60332-1-2. Standard reference is not a certification claim.

N2XSY Medium Voltage Cable for Utility and Industrial Networks

XWA manufactures medium-voltage cable configurations for distribution networks, trafo merkezleri, renewable energy routes and industrial feeders.

N2XSY Cable Technical Data

XWA 6/10kV N2XSY Cable

Recommended Reference Data: N2XSY is normally a single-core screened medium-voltage cable. The size format below is conductor cross-section / copper screen cross-section in mm2.

Ampacity values are reference values for one single-core circuit in air at 30°C or in ground at 20°C. Final project current rating depends on soil thermal resistivity, gömme derinliği, spacing, gruplama, sheath bonding, route temperature and local calculation method. Final XWA manufacturing dimensions and test values follow the approved quotation datasheet.

N2XSY 6/10 kV Recommended Data

Voltage classCable sizeConductor resistance at 20 C (ohm/km)Yalıtım kalınlığı (mm)Sheath thickness (mm)Yaklaşık. OD (mm)Yaklaşık. ağırlık (kg/km)Ampacity in air 30 C (A)Ampacity in ground 20 C (A)
6/10 kV1 X 35/160.5243.42.124920197187
6/10 kV1 X 50/160.3873.42.1251100236220
6/10 kV1 X 70/160.2683.42.1271300294268
6/10 kV1 X 95/160.1933.42.1281600358320
6/10 kV1 X 120/160.1533.42.1301850413363
6/10 kV1 X 150/250.1243.42.1312200468405
6/10 kV1 X 240/250.07543.42.1353150631526
6/10 kV1 X 400/350.04703.42.1414650827662
6/10 kV1 X 500/350.03663.42.1445700949744

N2XSY 12/20 kV Recommended Data

Voltage classCable sizeConductor resistance at 20 C (ohm/km)Yalıtım kalınlığı (mm)Sheath thickness (mm)Yaklaşık. OD (mm)Yaklaşık. ağırlık (kg/km)Ampacity in air 30 C (A)Ampacity in ground 20 C (A)
12/20 kV1 X 35/160.5245.52.1281100200189
12/20 kV1 X 50/160.3875.52.1291250239222
12/20 kV1 X 70/160.2685.52.1311500297271
12/20 kV1 X 95/160.1935.52.1321800361323
12/20 kV1 X 120/160.1535.52.1342050416367
12/20 kV1 X 150/250.1245.52.1352400470409
12/20 kV1 X 240/250.07545.52.1403400634532
12/20 kV1 X 400/350.04705.52.1454950829671
12/20 kV1 X 500/350.03665.52.1496050953754

N2XSY 18/30 kV Recommended Data

Voltage classCable sizeConductor resistance at 20 C (ohm/km)Yalıtım kalınlığı (mm)Sheath thickness (mm)Yaklaşık. OD (mm)Yaklaşık. ağırlık (kg/km)Ampacity in air 30 C (A)Ampacity in ground 20 C (A)
18/30 kV1 X 35/160.5248.02.1331350202191
18/30 kV1 X 50/160.3878.02.1341550241225
18/30 kV1 X 70/160.2688.02.1361750299274
18/30 kV1 X 95/160.1938.02.1372050363327
18/30 kV1 X 120/160.1538.02.1392350418371
18/30 kV1 X 150/250.1248.02.1402700472414
18/30 kV1 X 240/250.07548.02.1443700635539
18/30 kV1 X 400/350.04708.02.1505350831680
18/30 kV1 X 500/350.03668.02.1536450953765

N2XSY Cable Construction

N2XSY is built around a stranded copper conductor with an extruded conductor screen, XLPE insulation and an insulation screen applied as part of the medium-voltage insulation system. A copper wire screen and counter helix provide the metallic screen path, followed by a PVC outer sheath.

The single-core construction is important. Current rating, screen bonding, induced sheath voltage, bending radius and termination design are evaluated differently from three-core MV cable. Where a tender requires a three-core screened cable, N2XSEY or another three-core designation may be the better match.

The copper screen section, commonly shown as the second number in a size such as 1 X 240/25 mm2, is selected according to earth-fault current and protection design. It is not decorative and must match the fault-current requirement of the system.

Applications for N2XSY Medium Voltage Cable

N2XSY cable is used in medium-voltage distribution networks where a screened single-core cable with PVC sheath is accepted by the project specification. Common routes include transformer stations, switching stations, power plants, endüstriyel besleyiciler, renewable-energy collection networks and utility distribution circuits.

The cable can be installed indoors, outdoors, in ducts and in ground routes when the installation design accounts for mechanical protection, pulling tension, bükülme yarıçapı, route temperature and current rating. The PVC sheath gives a practical outer covering for many fixed installations, but route protection remains part of the cable system design.

For direct sunlight exposure, local standards and sheath performance requirements must be checked. For tunnels, public buildings or routes requiring low smoke and halogen-free performance, an LSZH medium-voltage cable can be a more suitable design than N2XSY.

N2XSY vs NA2XSY, N2XS2Y and N2XSEY

N2XSY and NA2XSY share the same basic screened MV cable logic, but the conductor material is different. N2XSY uses copper; NA2XSY uses aluminium. Copper gives a smaller conductor size for the same resistance, while aluminium can reduce conductor cost and cable weight where larger cross-sections and compatible terminations are acceptable.

N2XSY and N2XS2Y differ mainly in sheath material. N2XSY uses PVC sheath, while N2XS2Y uses PE sheath. PE sheath can be preferred for some underground routes because of moisture and abrasion resistance, while PVC may be selected where flame behaviour, handling or project convention points to PVC.

N2XSEY is commonly associated with three-core medium-voltage construction. It should not be treated as the same product as single-core N2XSY. The correct model depends on circuit design, installation route, magnetic effects, screen bonding method and termination arrangement.

ModeliMain distinctionTypical page role
N2XSYBakır iletken, XLPE izolasyonu, bakır tel ekran, PVC sheathThis page
NA2XSYAluminium conductor version with PVC sheathNext companion page
N2XS2YCopper conductor version with PE sheathUnderground-route comparison
N2XSEYThree-core screened MV constructionSeparate three-core intent

Test, Documents and Export Packing

N2XSY production documentation can include the approved datasheet, conductor resistance checks, voltage test records, partial-discharge test records, dimensional inspection, drum schedule, packing list and product photos. Type tests, flame-test evidence or third-party inspection are added only when required by the project and available for the exact construction.

Export packing is normally planned by cable weight, tambur uzunluğu, maximum drum diameter, route handling and container loading. Medium-voltage single-core cable can become heavy at large cross-sections, so drum length is part of the technical and logistics review, not only a shipping preference.

For quotation, XWA needs the model designation, voltage class, iletken boyutu, copper screen section, installation route, standart, miktar, preferred drum length, destination country and required documents. The information is used to confirm the cable configuration and issue a project-specific offer.

N2XSY Cable application in medium voltage distribution network
Medium-voltage cable route reference for industrial and utility distribution.

N2XSY Cable FAQs

What is N2XSY Cable?

N2XSY Cable is a screened single-core medium-voltage power cable with a copper conductor, XLPE izolasyonu, copper wire screen and PVC outer sheath. It is used for fixed MV distribution routes in utility, substation, industrial and generation systems.

Common N2XSY voltage classes include 6/10 kV, 8.7/15 kV, 12/20 kV and 18/30 kV. The project cable schedule defines the required Uo/U voltage class and test-voltage requirement.

The typical construction is Class 2 stranded copper conductor, conductor screen, XLPE izolasyonu, insulation screen, copper wire metallic screen with counter helix and PVC outer sheath. The screen section and sheath colour are specified by the project.

N2XSY is normally a single-core medium-voltage cable. Three-core MV requirements should be checked separately because the cable design, screen arrangement, bending radius and accessories are different.

In a size such as 1 X 240/25 mm2, 240 mm2 is the copper conductor cross-section and 25 mm2 is the copper screen cross-section. The screen value must match the earth-fault duty and protection design.

N2XSY is used in transformer stations, switching stations, power plants, industrial distribution networks, renewable-energy collection circuits, cable ducts and underground utility routes where PVC-sheathed MV cable is accepted.

N2XSY uses a copper conductor. NA2XSY uses an aluminium conductor with a similar screened XLPE/PVC construction. The choice affects conductor size, cable weight, termination design and commercial comparison.

N2XSY uses a PVC outer sheath. N2XS2Y uses a PE outer sheath. PE sheath can be preferred for certain underground and moisture-exposed routes, while PVC sheath remains common for many fixed MV installations.

N2XSY can be installed in ground routes when the cable design, route protection and local rules permit it. Current rating and service life depend on burial depth, soil thermal resistivity, spacing, gruplama, moisture and mechanical protection.

For a project quotation, XWA needs the N2XSY voltage class, iletken boyutu, copper screen section, standart, installation route, miktar, tambur uzunluğu, destination country and required inspection or test documents.

XWA MV orta gerilim kablosu 6kV 10kV zırhlı XLPE

OG Güç Kablosu

Medium-voltage cable systems for distribution, substations and industrial feeders.

11kV Kablo Yapısı

11kV Kablo

Medium-voltage cable page for 11kV distribution and project cable schedules.

XWA Vaka Çalışmaları & Projeler

    Ücretsiz Fiyat Teklifi Alın 24 Saat

    E-posta*:

    İsim*:

    Ülkeniz:

    Tel*:

    Gereksinimleriniz*: