XLPE/SWA/LSZH Cable

ファパワー & ケーブル | ARMOURED HALOGEN-FREE CONSTRUCTIONS

XLPE/SWA/LSZH Cable combines cross-linked polyethylene insulation, steel wire armour and a low-smoke zero-halogen outer sheath. It is a construction family for fixed power routes where mechanical protection and specified smoke and gas performance are both important.

In enclosed power routes, smoke and combustion gases deserve attention alongside mechanical protection. Our recommendation is to treat the insulation, フィラー, bedding and sheath as one material system, with the required smoke, gas and flame tests specified together. Rated voltage and metallic screens then define the electrical construction for the circuit.

Discuss an LSZH armoured cable project
絶縁
XLPE
Mechanical layer
鋼線装甲
アウターシース
低煙, zero halogen

XLPE/SWA/LSZH layer combinations

An unscreened construction is CU/XLPE/LSZH/SWA/LSZH: copper conductor, XLPE絶縁体, halogen-free bedding, wire armour and halogen-free sheath. Whole-cable smoke and halogen performance depends on the bedding, fillers and other non-metallic components as well as the outer sheath.

Unscreened distribution construction

Multicore LV designs combine the insulated core assembly with bedding, SWA and an outer sheath. Equal-section cores, reduced neutrals and protective cores are separate circuit arrangements; conductor material and core count remain part of the specification.

Screened MV construction

A screened MV example is CU/XLPE/CTS/LSZH/SWA/LSZH. Semiconductive layers control the electric field, the copper tape screen performs the specified electrical duty, and steel wire armour protects the assembly mechanically. Copper-wire screening is another option.

4 芯銅ケーブルの切断端。色付きの芯絶縁体と外装ワイヤーのリングが見える
Four-core cable cross-section with copper conductors and steel wire armour.

Screened three-core cable construction

Three-core XLPE/SWA/LSZH cable illustration showing copper conductors, 絶縁, 金属スクリーン, inner bedding, steel wire armour and outer sheath
Screened three-core XLPE/SWA/LSZH construction. 図 – 縮尺が合わない.
ElementWhat it contributesWhat the short name leaves open
Copper or aluminium conductorCarries circuit current材料, クラス, shape, section and neutral/earth arrangement.
XLPE絶縁体Separates conductors electrically定格電圧, insulation thickness and any field-control layers.
Fillers and beddingSupports the laid-up cores and armourCompound, tape system and their contribution to declared fire properties.
鋼線装甲Mechanical protection around a multicore assemblyWire dimensions, corrosion protection and bonding/protective-conductor assessment.
LSZHアウターシースSpecified smoke and halogen-related performanceCompound grade, 火災試験, weather resistance and environmental limits.

SWA is commonly used around multicore AC assemblies. Single-core AC circuits generally use non-magnetic armour, such as aluminium wire armour, to control magnetic losses and heating.

Low-smoke materials and fire-performance requirements

An LSZH cable design combines the insulation, フィラー, 寝具, tapes and outer sheath with the specified smoke and combustion-gas requirements. This material selection is particularly relevant to enclosed power routes and occupied buildings.

PropertyRelevant test frameworkMeaning for a project
Smoke emissionIEC 61034-2Assesses smoke under defined cable-burning conditions; not a promise of zero smoke.
Halogen acid gasIEC 60754-1Tests gases from cable materials against the specified requirements.
Acidity and conductivityIEC 60754-2Assesses gas-related acidity/conductivity; separate from optical smoke measurement.
延焼Applicable IEC 60332 テストSingle-cable and bunched-cable tests are different scopes.
Circuit integrity in fireApplicable fire-resistance specificationRequires a separately qualified design and test; it is not established by LSZH or SWA.

の official smoke-test procedure explains how smoke emission is measured under IEC 61034-2. The project specification sets the required smoke, gas and flame-spread performance; circuit integrity during fire is a separate tested requirement.

Voltage and screens define each power-cable design

Construction scopeLayer distinctionTechnical information carried by its datasheet
LV armoured power cableXLPE-insulated core assembly, halogen-free bedding, SWA and LSZH sheath電圧, core functions, conductor class and shape, 寸法, installation limits and fire declarations.
MV screened armoured power cableAdditional semiconductive layers and metallic screening matched to the voltageScreen construction and fault duty, 断熱システム, アクセサリー, bonding and project installation rating.
Higher-voltage project requestA complete cable-system design, not an LV construction scaled upApplicable system standard, metallic sheath/screen, 損失, ボンディング, accessories and qualification evidence.

The dimensions below cover a four-core 0.6/1 kV建設. Medium-voltage cable systems use additional electrical screens and voltage-specific insulation, with their own dimensions and accessories. Higher-voltage systems require a dedicated cable-system design.

Large-section reference: four-core copper, 0.6/1 kV

推奨参考データ: four equal-section class 2 copper cores, XLPE絶縁体, LSZH bedding, SWA and LSZH sheath. These published reference dimensions support preliminary planning; final supply dimensions follow the agreed XWA datasheet.

Cores × section (mm²)マックス. 20℃における直流抵抗 (Ω/km)絶縁 (mm)アウターシース (mm)全体の直径 (mm)約. 質量 (kg/km)
4 × 500.3871.02.134.53400
4 × 700.2681.12.239.64727
4 × 950.1931.12.444.06567
4 × 1200.1531.22.649.97748
4 × 1500.1241.42.754.39609
4 × 2400.07541.73.166.114496

Insulation and sheath thicknesses are nominal in this reference. Other conductor shapes, bedding compounds and armour dimensions produce different overall diameters and weights even at the same nominal section. Three-core, five-core and reduced-neutral designs need their own rows.

Current rating is calculated for the installation method, loaded cores, 周囲温度, grouping and soil conditions. The project datasheet and route calculation establish the circuit rating.

Finished diameter determines gland entry and termination space. 寝具, sheath and armour dimensions also affect mass and bending behaviour, so accessory selection follows the finished cable dimensions.

Mechanical protection on routes with smoke and gas requirements

This construction is used for fixed power distribution in industrial facilities, transport infrastructure, plant rooms and building-service routes where mechanical protection and specified smoke and gas performance are required.

Indoor-to-outdoor routes combine fire-performance requirements with exposure conditions. Sheath compound selection addresses UV, 水分, hydrocarbons, chemicals and installation temperature for the actual route.

For wet routes, dedicated water-blocking layers can be specified alongside mechanical armour. Moving, suspended and subsea applications require constructions designed for those mechanical and environmental duties.

XWA cable manufacturing and project supply

XWAパワー & Cable manufactures power cables in Henan, 中国. Conductor processing, 絶縁押出, armouring and sheathing are part of our cable factory operations.

XWA supports cable manufacturing to project drawings and cable schedules. The agreed LSZH design brings together the electrical rating, non-metallic materials and specified smoke, halogen and flame tests.

Delivery length is part of the configuration. The finished diameter and mass establish a starting point for drum dimensions, handling equipment and route pulling arrangements; gross drum weight includes more than cable conductor weight.

Large steel cable reels with wound black cable on a factory floor
Steel reels with wound cable for handling and drum planning.

Questions about the LSZH armoured structure

What does XLPE/SWA/LSZH mean?

XLPE identifies the insulation, SWA the steel wire armour and LSZH the low-smoke zero-halogen outer-sheath family. 導体, 寝具, 画面, voltage and test requirements complete the specification.

Is CU/XLPE/LSZH/SWA/LSZH a separate model name?

It describes the layers from the centre outwards: copper conductor, XLPE絶縁体, LSZH bedding, steel wire armour and LSZH outer sheath.

Can this structure be used for medium voltage?

はい. Screened MV constructions combine XLPE insulation, voltage-appropriate semiconductive layers, a metallic screen, armour and an LSZH sheath system. Screen fault duty, dimensions and accessories are selected for the voltage rating.

Does an LSZH outer sheath make PVC bedding halogen-free?

PVC bedding contains halogen. A whole-cable halogen-free specification addresses the fillers, 寝具, tapes and sheath together, with the corresponding material and test requirements.

Is XLPE/SWA/LSZH cable fire-resistant?

LSZH describes smoke and halogen-related properties. Continued circuit operation during fire requires a fire-resistant construction and a corresponding circuit-integrity test.

Can steel wire armour replace a copper screen?

Steel wire armour provides mechanical protection; a copper screen performs the specified electrical duty. A screened MV armoured cable contains both layers.

Request an XLPE/SWA/LSZH cable quotation

Discuss your LSZH cable requirement with XWA. Email a cable schedule, or tell us the voltage, core size and length, together with any specified fire-performance requirements.

info@xwacable.com
ワッツアップ: +86 15324981792

    無料見積もりを入手する 24 営業時間

    電子メール*:

    名前*:

    あなたの国:

    電話番号*:

    あなたの要件*: