Transformer project supply
Distribution transformers convert network voltage to the level required by buildings, industrial loads and local power systems. XWA offers a project supply route through a specialist transformer manufacturing partner, with oil-immersed and cast-resin configurations for different installation environments.
The 10/10.5 kV до 0.4 kV families include ratings from 30 to 2,500 kVA. Separate 35 kV designs serve higher-voltage distribution duties. Capacity, voltage ratio, cooling and winding connections are matched to the electrical system rather than selected as isolated catalogue numbers.
XWA works with a specialist transformer manufacturing partner to develop the technical and commercial response to project enquiries.

Oil-immersed and cast-resin distribution designs
| Строителство | Изолация / охлаждане | Typical installation | Product details |
|---|---|---|---|
| Oil-immersed | Insulating oil and tank cooling surfaces | Outdoor utility and industrial distribution | Oil-immersed transformer details |
| Cast-resin dry type | Solid winding insulation and air cooling | Indoor electrical rooms and building substations | Dry type transformer details |
Oil-immersed and dry-type transformers perform the same voltage-conversion function but create different installation requirements. Tank cooling, containment, вентилация, room layout and maintenance access influence the appropriate construction.
For an indoor project, we would establish the room ventilation and fire strategy before choosing solely on footprint. For an outdoor distribution point, the oil-filled tank and its cooling surfaces often provide a practical self-contained arrangement.

Capacity and voltage combinations
| Семейство продукти | Capacity series | Primary / secondary | Configuration |
|---|---|---|---|
| S-M oil-immersed | 30–2,500 kVA | 10 или 10.5 kV / 0.4 kV | Sealed three-phase distribution family |
| SC(B) cast-resin | 30–2,500 kVA | 10 или 10.5 kV / 0.4 kV | Three-phase air-cooled family |
| 35 kV two-winding designs | Model-specific rating schedule | 35 kV primary; defined distribution secondary | Separate insulation and impedance schedule |
Dyn11 and Yyn0 are winding-connection options in the detailed 10 kV distribution families. The neutral connection, system earthing and any parallel operation determine the required arrangement. The exact frequency, tap range, impedance and cooling rating are recorded together in the project datasheet.
Distribution duty and power-transformer duty
Distribution transformers generally serve the local network and its end loads. Larger power transformers may serve bulk transmission or primary substation duties. The practical distinction depends on the network function and specification rather than one universal capacity threshold.
Rated current connects the kVA rating to the site
For a three-phase transformer, rated line current is apparent power divided by √3 times line-to-line voltage. При 400 V, 500 kVA corresponds to approximately 722 А и 1,000 kVA to approximately 1,443 А.
These values help explain the scale of the low-voltage terminal and busbar connection. Equipment selection also considers protection coordination, режим на късо съединение, thermal conditions and the actual load.
Losses follow the operating pattern
No-load loss continues while a transformer is energised; load loss changes with loading and winding temperature. A continuously energised, lightly loaded substation places different emphasis on core loss from a heavily loaded industrial supply. Comparing both loss components at their stated reference conditions makes the technical comparison more useful.

Distribution transformers for buildings and industry
| Project duty | Configuration focus |
|---|---|
| Industrial power supply | Load profile, motor starting, impedance, terminal access and possible expansion. |
| Commercial and public buildings | Indoor layout, вентилация, acoustic conditions and access for replacement. |
| Utility and infrastructure networks | Voltage ratio, winding connections, taps and the utility protection scheme. |
| Renewable-energy auxiliary supply | Site-service voltage and load requirements, distinct from the main generation step-up duty. |
The transformer is one part of the complete supply path. Its terminals, protection and installation arrangement need to work with the site switchgear and earthing system. A single-line diagram makes those interfaces clear during the project discussion.
Technical documentation and inspection
IEC 60076-1 provides the general power-transformer framework. Liquid-immersed temperature-rise requirements and dry-type requirements are addressed in the relevant parts of the series. The contract identifies the applicable editions and the selected product configuration.
A project inspection schedule typically addresses winding resistance, voltage ratio, phase displacement, losses and dielectric performance. Additional tests, witness points and acceptance values follow the agreed requirements. Overall dimensions, terminal drawings, lifting arrangements and transport configuration support installation and delivery planning.
справка: IEC general transformer requirements.
Distribution Transformer FAQs
What does a distribution transformer do?
It changes distribution-network voltage to the level required by local loads. A common three-phase example is a 10 kV до 0.4 kV transformer supplying an industrial or building network.
Are all distribution transformers oil-immersed?
Oil-immersed and dry-type constructions both serve distribution duties. Their insulation and cooling arrangements create different requirements for the installation location.
Are 500 kVA and 1000 kVA ratings real-power values?
They are apparent-power ratings. The real power delivered at a given load depends on power factor and operating conditions; kVA should not be treated as the same number of kW.
How does a project enquiry start?
Capacity, voltage ratio, честота, количество, location and a single-line diagram provide a useful starting point. XWA can discuss the configuration with the transformer manufacturing partner and develop the quotation.
Discuss your transformer project with XWA
Send the capacity, primary and secondary voltages, честота, количество и предназначение. Include your single-line diagram or technical schedule if available. XWA will discuss the configuration and commercial requirements with our transformer manufacturing partner.
Explore the power transformer range or use the XWA contact page to start the conversation.
