Distribution Grade MV Cable

MV Power Cable for 6kV to 35kV Distribution Projects

MV power cable covers common IEC-rated cables from 3.6/6(7.2)kV до 18/30(36)kV, together with regional and project-specific 35kV-class constructions for distribution, industrial and renewable energy systems.

6–35kVMV distribution cable systems
Project-EngineeredConstruction matched to network conditions
Underground & IndustrialFeeders, substations and energy routes
IEC / Project SpecMV design and testing framework
XWA MV power cable for 6kV to 35kV distribution projects
MV power cable range for underground distribution, substations and industrial feeder systems.

XWA MV Power Cable

As a medium voltage cable manufacturer, XWA supplies 6kV to 35kV cable constructions for distribution networks, substations, industrial plants and renewable energy collection systems, with copper or aluminum conductors, screened insulation systems, armoring options and sheath materials matched to project specifications.

XWA’s engineering team develops each MV cable construction according to the rated voltage, размер на проводника, core arrangement, дизайн на екрана, armoring requirement, water-blocking condition and installation environment for underground, канал, tray and direct-burial routes.

MV Cable by Voltage Class

Explore distribution cable classes and their product specifications. U0 is the conductor-to-earth rating, U the conductor-to-conductor rating, and Um the highest system voltage for the cable.

The project network voltage, earthing arrangement and fault-clearing time determine the required cable rating. For an 11 kV system, проучете 11kV cable range and its specified U0/U(един) ratings.

North American MV Cable

North American medium voltage cable classes are normally named by nominal system voltage, while IEC cable pages use U0/U(един) designations. XWA separates these terms so voltage selection, standards discussion and cable construction remain clear.

5kV, 15kV, 25kV and 35kV Classes

North American MV Cable covers nominal voltage classes used in utility, industrial, renewable energy and feeder systems.

Different Naming Basis

IEC pages use U0/U(един), като например 8.7/15(17.5)kV, while North American schedules commonly use 5kV, 15kV, 25kV or 35kV class names.

Project Specification Review

XWA reviews conductor, ниво на изолация, shield system, jacket, installation route and required standard scope before confirming the cable construction.

Medium Voltage Cable Models

Compare conductor material, обвивка, water protection and core arrangement across the screened XLPE cable range.

PVC and PE Sheathed Cables

Water-Blocked MV Cables

Halogen-Free and Three-Core Cables

MV power cable is used between low-voltage distribution and high-voltage transmission systems. It supports feeder circuits, transformer substations, industrial power intake, wind and solar collection networks, mining power distribution and municipal underground grids where screened insulation and controlled earthing are required.

XWA produces medium voltage cable in single-core and three-core constructions, including copper wire screened cable, copper tape screened cable, steel wire armoured cable, steel tape armoured cable, aluminum wire armoured cable and water-blocked designs for demanding route conditions.

Distribution Voltage

Common project classes include 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV, 18/30kV and 26/35kV cable designs.

Screened XLPE System

Manufactured with conductor screen, XLPE изолация, insulation screen and metallic screen layers for stable electric field control.

Installation Options

Factory configurations cover duct, тава, директно погребение, тунел, substation, renewable energy and industrial feeder applications.

MV XLPE Cable Construction

XWA produces medium voltage XLPE cable with a screened insulation system and route-specific mechanical protection. A typical MV cable includes a compacted copper or aluminum conductor, проводников екран, XLPE изолация, изолационен екран, метален екран, bedding layer, optional armor and an outer sheath selected for the installation environment.

ДиригентCompacted copper or aluminium conductors for the selected MV design
Core ArrangementЕдноядрен, three-core and triplex configurations for MV distribution systems
Insulation SystemПроводник екран, XLPE insulation and insulation screen
Метален екранCopper wires or copper tape, with screen area and bonding matched to the circuit
Armor and SheathPVC, PE or LSZH sheath; SWA or STA for specified multicore designs, and non-magnetic armour for single-core AC designs

For a wet underground route, we would consider the sheath and water barriers together. A PE jacket protects the outside of the cable, while longitudinal and radial barriers address different paths of moisture entry.

MV XLPE cable construction with single-core and three-core screened cable sections

MV Cable Ratings and Construction Parameters

XWA manufactures medium voltage power cable for distribution and industrial systems from 3.6/6kV to 26/35(40.5)kV. IEC 60502-2 is normally used for extruded-insulation power cables from 6kV up to 30kV rated voltage classes. For 26/35(40.5)kV systems, XWA confirms the applicable project, utility or local specification before finalizing the cable construction.

Voltage ClassCommon Voltage DesignationApplicable StandardProduct Page
6kV3.6/6(7.2)kVIEC 60502-2 project specifications6kV кабел
10kV6/10(12)kVIEC 60502-2 project specifications10kV кабел
15kV8.7/15(17.5)kVIEC 60502-2 project specifications15kV кабел
20kV12/20(24)kVIEC 60502-2 project specifications20kV кабел
30kV18/30(36)kVIEC 60502-2 project specifications33kV кабел
35kV26/35(40.5)kVProject, utility or local specifications35kV кабел

What Defines the Finished Cable

Conductor area, screen size and core arrangement define the electrical design; sheath and armour determine how the cable fits its route. The finished diameter and mass follow that complete construction.

Current rating is calculated for the actual conductor, laying arrangement, ambient or soil temperature, soil thermal resistivity and circuit spacing. Single-core and three-core constructions retain separate dimensional schedules.
ПараметърConfigurationPractical effect
ДиригентCopper or aluminium; cross-section specified for the circuitСъпротива, загуби, termination size and handling weight
Подреждане на ядротоSingle-core circuits, triplex arrangements or three-core cableRoute space, pulling arrangement and accessories
ИзолацияXLPE with conductor and insulation screensInsulation thickness follows the rated voltage and product specification
Метален екранWire or tape construction; screen area specified separatelyEarth-fault duty and the bonding arrangement
Външна защитаPVC, PE, LSZH; specified armour or water barriersMechanical protection, moisture exposure and fire-performance requirements
Finished dimensionsModel-specific diameter, mass and bending dataDuct clearance, планиране на барабана, pulling and termination fit
Medium Voltage Cable Catalogue PDFDownload XWA medium voltage cable catalogue for voltage classes, construction options and reference product information.
Download PDF
Medium voltage cable factory testing and quality control

Distribution, Substation and Renewable Energy Routes

As an international medium voltage cable manufacturer, XWA focuses on underground distribution circuits, transformer substations, industrial feeders, mining power systems, tunnel routes and renewable energy collection networks. Route design can include steel wire armor, steel tape armor, aluminum wire armor, PE sheath, LSZH sheath, semiconductive sheath and water-blocked layers according to mechanical, environmental and earthing requirements.

Medium voltage cable production is arranged around cable construction, dimensional control, insulation extrusion, screen continuity, sheath integrity and routine testing records within the agreed project scope.

MV Cable Engineering Resources

Explore the details behind screen design, installation routes and factory testing.

Screen bonding

Single-point, both-end and cross-bonding arrangements for metallic screens.

Underground routes

How route conditions influence the sheath, water protection and installation design.

Partial discharge testing

What the test checks and how the test record supports cable inspection.

Related cable ranges: low voltage power cable, кабел за високо напрежение, submarine cable.

Medium Voltage Cable Questions

What is MV power cable?

MV power cable is an insulated medium voltage cable system used for electrical distribution between low-voltage equipment and high-voltage transmission networks. It commonly includes a conductor, проводников екран, XLPE изолация, изолационен екран, метален екран, постелки, optional armor and outer sheath.

What voltage range does XWA MV power cable cover?

XWA manufactures common medium voltage cable classes from 3.6/6(7.2)kV до 26/35(40.5)kV, including 6kV, 10kV, 11kV, 15kV, 20kV, 30kV, 33kV and 35kV distribution systems.

Which standard applies to MV XLPE power cable?

IEC 60502-2 is normally used for extruded-insulation medium voltage power cable through 18/30(36)kV. For 26/35(40.5)kV systems, XWA confirms the applicable project, utility or local specification before production.

Are IEC 15kV and North American 15kV cable ratings the same?

IEC schedules identify U0/U(един), for example 8.7/15(17.5)kV. North American 15kV class specifications also use an insulation level and their applicable product standard. The nominal class name alone does not establish the same cable construction or rating.

What MV cable constructions are available?

XWA supplies single-core and three-core MV cable constructions with copper or aluminum conductors, copper tape or copper wire screens, PVC, PE or LSZH sheaths and armored or unarmored options.

How do N2XS2Y, N2XS(Е)2Y and N2XS(ЕТ)2Y differ?

N2XS2Y uses a PE outer sheath. N2XS(Е)2Y adds longitudinal water blocking, while N2XS(ЕТ)2Y combines longitudinal blocking with a radial moisture barrier. The route moisture conditions determine which protection is appropriate.

How does XWA control MV cable production quality?

XWA prepares MV cable production with conductor preparation, triple extrusion where applicable, screen application, брониране, sheath extrusion, dimensional checks, voltage testing and routine test records according to the agreed specification.

How does XWA prepare MV cable offers?

XWA reviews voltage designation, материал и размер на проводника, брой ядра, screen type, броня, материал на обвивката, инсталационен път, standard and drum length before preparing the cable construction and offer.

Contact XWA for MV Cable Projects

XWA prepares MV cable offers around voltage class, проводников материал, core construction, screen type, броня, sheath design and required standard, with cable construction matched to the confirmed project specification.

Voltage classes: 3.6/6kV до 26/35(40.5)kV Строителство: XLPE insulated screened MV power cable Приложения: distribution, substation, industrial and renewable energy systems