สาย NA2XSY

สาย NA2XSY

สาย NA2XSY is a single-core medium-voltage power cable with a stranded aluminium conductor, ฉนวน XLPE, copper wire screen and PVC outer sheath.

The designation is used for fixed medium-voltage distribution in transformer stations, switching substations, power plants, industrial networks, renewable-energy collection systems and utility cable routes. Common project voltage classes include 6/10 กิโลโวลต์, 8.7/15 กิโลโวลต์, 12/20 กิโลโวลต์และ 18/30 kV under IEC and VDE-oriented specifications.

XWA supplies NA2XSY as a project cable configuration where aluminium conductor size, copper screen section, ระดับแรงดันไฟฟ้า, sheath colour, test documents and export packing are matched to the cable schedule and destination market.

NA2XSY Cable aluminum conductor medium voltage XLPE insulated PVC sheathed cable

CONSTRUCTION

คอนดักเตอร์:

ระดับ 2 stranded aluminium conductor, round compacted where specified

ฉนวนกันความร้อน:

XLPE insulation with inner and outer semiconductive screens

หน้าจอเมทัลลิก:

Copper wire screen with counter helix; screen section selected by fault-current requirement

เปลือกนอก:

PVC outer sheath, commonly red for MV identification; colour and UV requirement follow project specification

CHARACTERISTICS

Voltage Classes:

6/10 กิโลโวลต์, 8.7/15 กิโลโวลต์, 12/20 กิโลโวลต์และ 18/30 kV project classes

Conductor Temperature:

XLPE medium-voltage designs commonly use 90°C maximum conductor temperature in normal service

การติดตั้ง:

Fixed installation indoors, outdoors, in ducts and in ground routes with suitable mechanical and thermal design

STANDARDS:

Common references include IEC 60502-2, VDE 0276-620, ไออีซี 60228 และไออีซี 60332-1-2. Standard reference is not a certification claim.

NA2XSY Medium Voltage Cable for Utility and Industrial Networks

XWA manufactures medium-voltage cable configurations for distribution networks, substations, renewable energy routes and industrial feeders.

NA2XSY Cable Technical Data

ข้อมูลอ้างอิงที่แนะนำ: NA2XSY is normally a single-core screened medium-voltage cable. The size format below is conductor cross-section / copper screen cross-section in mm2.

Ampacity values are reference values for one single-core circuit in air at 30°C or in ground at 20°C. Final project current rating depends on soil thermal resistivity, burial depth, spacing, grouping, พันธะฝัก, route temperature and local calculation method. Final XWA manufacturing dimensions and test values follow the approved quotation datasheet.

NA2XSY 6/10 kV Recommended Data

Voltage classCable sizeAluminium conductor resistance at 20 C (โอห์ม/กม)Insulation thickness (มม)Sheath thickness (มม)ประมาณ. ของ (มม)ประมาณ. น้ำหนัก (กก./กม)Ampacity in air 30 C (ก)Ampacity in ground 20 C (ก)
6/10 กิโลโวลต์1 x 50/160.6413.42.125780183171
6/10 กิโลโวลต์1 x 70/160.4433.42.127870228208
6/10 กิโลโวลต์1 x 95/160.3203.42.128990278248
6/10 กิโลโวลต์1 x 120/160.2533.42.1301100321283
6/10 กิโลโวลต์1 x 150/250.2063.42.1311300364315
6/10 กิโลโวลต์1 x 185/250.1643.42.1331450418357
6/10 กิโลโวลต์1 x 240/250.1253.42.1351650494413
6/10 กิโลโวลต์1 x 400/350.07783.42.1412350660535
6/10 กิโลโวลต์1 x 500/350.06053.42.1442700767602

NA2XSY 12/20 kV Recommended Data

Voltage classCable sizeAluminium conductor resistance at 20 C (โอห์ม/กม)Insulation thickness (มม)Sheath thickness (มม)ประมาณ. ของ (มม)ประมาณ. น้ำหนัก (กก./กม)Ampacity in air 30 C (ก)Ampacity in ground 20 C (ก)
12/20 กิโลโวลต์1 x 50/160.6415.52.129970185172
12/20 กิโลโวลต์1 x 70/160.4435.52.1311100231210
12/20 กิโลโวลต์1 x 95/160.3205.52.1321200280251
12/20 กิโลโวลต์1 x 120/160.2535.52.1341350323285
12/20 กิโลโวลต์1 x 150/250.2065.52.1351500366319
12/20 กิโลโวลต์1 x 185/250.1645.52.1371700420361
12/20 กิโลโวลต์1 x 240/250.1255.52.1401900496417
12/20 กิโลโวลต์1 x 400/350.07785.52.1452600659541
12/20 กิโลโวลต์1 x 500/350.06055.52.1483000766609

NA2XSY 18/30 kV Recommended Data

Voltage classCable sizeAluminium conductor resistance at 20 C (โอห์ม/กม)Insulation thickness (มม)Sheath thickness (มม)ประมาณ. ของ (มม)ประมาณ. น้ำหนัก (กก./กม)Ampacity in air 30 C (ก)Ampacity in ground 20 C (ก)
18/30 กิโลโวลต์1 x 50/160.6418.02.1341250187174
18/30 กิโลโวลต์1 x 70/160.4438.02.1361350232213
18/30 กิโลโวลต์1 x 95/160.3208.02.1371500282254
18/30 กิโลโวลต์1 x 120/160.2538.02.1391600325289
18/30 กิโลโวลต์1 x 150/250.2068.02.1401850367322
18/30 กิโลโวลต์1 x 185/250.1648.02.1422000421364
18/30 กิโลโวลต์1 x 240/250.1258.02.1442250496422
18/30 กิโลโวลต์1 x 400/350.07788.02.1503000660529
18/30 กิโลโวลต์1 x 500/350.06058.02.1533450764616

NA2XSY Cable Construction

NA2XSY is built around a stranded aluminium conductor with an extruded conductor screen, XLPE insulation and an insulation screen applied as part of the medium-voltage insulation system. A copper wire screen and counter helix provide the metallic screen path, followed by a PVC outer sheath.

The single-core construction is important. Current rating, screen bonding, induced sheath voltage, bending radius and termination design are evaluated differently from three-core MV cable. Where a tender requires a three-core screened cable, N2XSEY or another three-core designation may be the better match.

The copper screen section, commonly shown as the second number in a size such as 1 x 240/25 mm2, is selected according to earth-fault current and protection design. It is not decorative and must match the fault-current requirement of the system.

Applications for NA2XSY Medium Voltage Cable

NA2XSY cable is used in medium-voltage distribution networks where a screened single-core cable with PVC sheath is accepted by the project specification. Common routes include transformer stations, switching stations, power plants, เครื่องป้อนอุตสาหกรรม, renewable-energy collection networks and utility distribution circuits.

The cable can be installed indoors, outdoors, in ducts and in ground routes when the installation design accounts for mechanical protection, pulling tension, bending radius, route temperature and current rating. The PVC sheath gives a practical outer covering for many fixed installations, but route protection remains part of the cable system design.

For direct sunlight exposure, local standards and sheath performance requirements must be checked. For tunnels, public buildings or routes requiring low smoke and halogen-free performance, an LSZH medium-voltage cable can be a more suitable design than NA2XSY.

NA2XSY vs N2XSY, N2XS2Y and N2XSEY

N2XSY and NA2XSY share the same basic screened MV cable logic, but the conductor material is different. N2XSY uses copper; NA2XSY uses aluminium. Copper gives a smaller conductor size for the same resistance, while aluminium can reduce conductor cost and cable weight where larger cross-sections and compatible terminations are acceptable.

NA2XSY and N2XS2Y differ mainly in sheath material. NA2XSY uses PVC sheath, while N2XS2Y uses PE sheath. PE sheath can be preferred for some underground routes because of moisture and abrasion resistance, while PVC may be selected where flame behaviour, handling or project convention points to PVC.

N2XSEY is commonly associated with three-core medium-voltage construction. It should not be treated as the same product as single-core NA2XSY. The correct model depends on circuit design, installation route, magnetic effects, screen bonding method and termination arrangement.

แบบอย่างMain distinctionTypical page role
N2XSYCopper conductor, ฉนวน XLPE, copper wire screen, PVC sheathCopper companion page
NA2XSYAluminium conductor, ฉนวน XLPE, copper wire screen, PVC sheathThis page
N2XS2YCopper conductor version with PE sheathUnderground-route comparison
N2XSEYThree-core screened MV constructionSeparate three-core intent

Testing, Documents and Export Packing

NA2XSY production documentation can include the approved datasheet, การตรวจสอบความต้านทานของตัวนำ, voltage test records, partial-discharge test records, dimensional inspection, drum schedule, packing list and product photos. Type tests, flame-test evidence or third-party inspection are added only when required by the project and available for the exact construction.

Export packing is normally planned by cable weight, drum length, maximum drum diameter, route handling and container loading. Medium-voltage single-core cable can become heavy at large cross-sections, so drum length is part of the technical and logistics review, not only a shipping preference.

For quotation, XWA needs the model designation, ระดับแรงดันไฟฟ้า, ขนาดตัวนำ, copper screen section, installation route, standard, ปริมาณ, preferred drum length, destination country and required documents. The information is used to confirm the cable configuration and issue a project-specific offer.

NA2XSY Cable FAQs

What is NA2XSY Cable?

NA2XSY Cable is a screened single-core medium-voltage power cable with an aluminium conductor, ฉนวน XLPE, copper wire screen and PVC outer sheath. It is used for fixed MV distribution routes in utility, substation, industrial and generation systems.

Common NA2XSY voltage classes include 6/10 กิโลโวลต์, 8.7/15 กิโลโวลต์, 12/20 กิโลโวลต์และ 18/30 กิโลโวลต์. The project cable schedule defines the required Uo/U voltage class and test-voltage requirement.

The typical construction is Class 2 stranded aluminium conductor, หน้าจอตัวนำ, ฉนวน XLPE, หน้าจอฉนวน, copper wire metallic screen with counter helix and PVC outer sheath. The screen section and sheath colour are specified by the project.

NA2XSY is normally a single-core medium-voltage cable. Three-core MV requirements should be checked separately because the cable design, screen arrangement, bending radius and accessories are different.

In a size such as 1 x 240/25 mm2, 240 mm2 is the aluminium conductor cross-section and 25 mm2 is the copper screen cross-section. The screen value must match the earth-fault duty and protection design.

NA2XSY is used in transformer stations, switching stations, power plants, industrial distribution networks, renewable-energy collection circuits, cable ducts and underground utility routes where PVC-sheathed MV cable is accepted.

NA2XSY uses an aluminium conductor. N2XSY uses a copper conductor with a similar screened XLPE/PVC construction. The choice affects conductor size, cable weight, termination design and commercial comparison.

NA2XSY uses a PVC outer sheath. N2XS2Y uses a PE outer sheath. PE sheath can be preferred for certain underground and moisture-exposed routes, while PVC sheath remains common for many fixed MV installations.

NA2XSY can be installed in ground routes when the cable design, route protection and local rules permit it. Current rating and service life depend on burial depth, soil thermal resistivity, spacing, grouping, moisture and mechanical protection.

For a project quotation, XWA needs the NA2XSY voltage class, ขนาดตัวนำ, copper screen section, standard, installation route, ปริมาณ, drum length, destination country and required inspection or test documents.

XWA 3.6-35kV MV Medium Voltage Cable

สายไฟเอ็มวี

Medium-voltage cable systems for distribution, substations and industrial feeders.

11kV Medium Voltage Cable

11สายเควี

Medium-voltage cable page for 11kV distribution and project cable schedules.

XWA Case Studies & โครงการ

    รับใบเสนอราคาฟรีได้ที่ 24 ชั่วโมง

    อีเมล*:

    ชื่อ*:

    ประเทศของคุณ:

    โทร*:

    ความต้องการของคุณ*: