35kV Medium-High Voltage Cable

35kV Cable – Key Specifications & การก่อสร้าง
- คอนดักเตอร์:High-purity annealed copper or aluminum conductor, available in various cross-sections (50mm² to 800mm²).
- ฉนวนกันความร้อน:เอ็กซ์แอลพีอี (เอทิลีนแบบเชื่อมโยงข้าม) or HEPR (Hard Ethylene Propylene Rubber) insulation, offering excellent thermal stability, high dielectric strength, and long-term aging resistance for 35kV high-voltage systems.
- Screen/Sheath:Triple-layer semi-conductive and metallic copper screen to precisely control electric fields and eliminate partial discharges; outer sheath (พีวีซี, วิชาพลศึกษา, or halogen-free LSZH compound) provides robust protection against oils, chemicals, UV radiation, และความเสียหายทางกล.
- เกราะ:Optional galvanized steel wire armor (สวา) or steel tape armor (STA) for enhanced mechanical protection against crushing, impact, rodent damage, and tensile stress in heavy-duty installation scenarios.
- ระดับแรงดันไฟฟ้า:35กิโลโวลต์ (26/35กิโลโวลต์, 21/35กิโลโวลต์, 18/30กิโลโวลต์(36กิโลโวลต์))
- การปฏิบัติตามมาตรฐาน:ไออีซี 60502-2, ไออีซี 60228, ไออีซี/อังกฤษ 60332-1-2, กิกะไบต์/ที 12706, กิกะไบต์/ที 11017
Technical Specifications of XWA 35kV Cable
| รายการ | พารามิเตอร์ | รายละเอียด |
|---|---|---|
| คอนดักเตอร์ | วัสดุ | High-purity annealed ทองแดง (ลูกบาศ์ก) / อลูมิเนียม (อัล) |
| Standard | ไออีซี 60228 (ระดับ 2/5) | |
| ภาพตัดขวาง | 50 มม.² ~ 800 มม.² (Customizable) | |
| ฉนวนกันความร้อน | วัสดุ | เอ็กซ์แอลพีอี (Cross-linked PE) / HEPR (Hard EPR) |
| ความหนา | ≥ 10.0 มม (per IEC 60502-2 for 26/35kV) | |
| Temp. Rating | 90องศาเซลเซียส (continuous); 130องศาเซลเซียส (short-term) | |
| Dielectric Strength | ≥ 30 kV/mm (DC) | ≥ 20 kV/mm (AC) | |
| Volume Resistivity | ≥ 1×10¹⁴ Ω·m (20องศาเซลเซียส) | |
| หน้าจอ | Inner Screen | Semi-conductive XLPE compound (thickness ≥ 1.5 มม) |
| หน้าจอเมทัลลิก | Copper tape (≥ 0.20 มม) / Copper strands (Mandatory) | |
| Outer Screen | Semi-conductive PE sheath (thickness ≥ 1.5 มม) | |
| Grounding Resistance | ≤ 0.3 Ω/km (20องศาเซลเซียส) | |
| เกราะ | พิมพ์ | สวา (ลวดเหล็ก) / STA (Steel Tape) (Optional) |
| เปลือกนอก | วัสดุ | พีวีซี / วิชาพลศึกษา / LSZH (Halogen-free) |
| ผลงาน | Bending Radius | ≥ 20D (Armored) / ≥ 15D (Unarmored) |
| มาตรฐาน | การปฏิบัติตาม | ไออีซี 60502-2, กิกะไบต์/ที 12706, กิกะไบต์/ที 11017, ซีอี, ไอเอสโอ 9001 |
Applications of XWA 35kV Cable
- Industrial Power Distribution: Reliable power supply for heavy machinery, manufacturing lines, processing units, and factory automation systems, ensuring stable operation in demanding industrial environments.
- Mining Operations: Robust armored construction withstands harsh terrain, vibration, and potential mechanical damage, making it ideal for surface and underground mining power networks.
- Infrastructure & Public Utilities: Used in tunnels, airports, water treatment plants, transportation hubs, and urban grid upgrades to power pumps, lighting, and critical public services.
- Renewable Energy Projects: Connects wind turbine generators, solar farm inverters, and energy storage systems to the main power grid, supporting large-scale clean energy infrastructure worldwide.
- Commercial & High-Rise Buildings: Serves as the main distribution feeder for large commercial complexes, hospitals, data centers, and high-rise office buildings.
- Utility & Power Grids: Primary and secondary power distribution for municipal and industrial utility grids, including overhead, direct burial, and duct installations.
- น้ำมัน & Gas Projects: Reliable power transmission for offshore platforms, onshore processing facilities, and remote oilfield operations, with resistance to chemical corrosion and extreme weather.
- ทางรถไฟ & Transportation: Supplies stable power to high-speed rail, subway systems, and airport infrastructure, ensuring uninterrupted operation of transportation networks.
FAQs of 10kV Cable
What is the rated voltage of XWA 35kV cable, and what does U0/U 26/35kV mean?
- U0 (26กิโลโวลต์): The maximum voltage that the cable insulation can withstand between the conductor and the earth (or metallic screen) during long-term operation.
- คุณ (35กิโลโวลต์): The maximum voltage between any two conductors of the cable during long-term operation.This voltage grade is specifically designed for 35kV high-voltage power transmission and distribution networks, ensuring safe and stable operation under high electric field stress.
What are the key installation requirements for XWA 35kV cable, especially for direct burial?
- Minimum bending radius: ≥ 20D (armored) or ≥ 15D (unarmored), where D is the cable outer diameter (stricter than 10kV cables to protect the thicker insulation).
- Burial depth: ≥ 1.0 เมตร (1.2 meters in traffic areas) to avoid mechanical damage and external stress.
- Protection layer: Sand cushion (≥ 100mm) and concrete/brick cover must be laid above the cable to prevent crushing.
- Avoidance: Keep away from chemical corrosion sources, high-temperature pipelines, and sharp objects to extend service life.
What is the design service life of XWA 35kV cable, and what factors affect it most?
- Operating temperature: Long-term operation above 90°C will accelerate XLPE insulation aging.
- Partial discharge: Poor manufacturing or installation can cause partial discharges, which gradually degrade the insulation.
- Environmental stress: UV radiation, chemical corrosion, and soil moisture will reduce insulation performance over time.
- Overload faults: Frequent short-circuit or overload events will damage the insulation and metallic screen.
Can XWA 35kV cable be customized for special project needs?
- คอนดักเตอร์: High-purity copper or aluminum, cross-sections from 50mm² to 800mm².
- ฉนวนกันความร้อน & ฝัก: XLPE/HEPR insulation, with PVC/PE/LSZH (halogen-free) sheath options.
- เกราะ: สวา (steel wire armor) or STA (steel tape armor) for enhanced mechanical protection.
- Special features: Water-blocking layers, fire-resistant structures, or custom lengths (supplied on steel drums for long lengths).
What other medium voltage cables do you provide?
In addition to 35kV cable, we also supply 6kV MV cables, 10kV MV Cables, and other medium voltage cables based on project requirements.
