Distribution Grade MV Cable

MV Power Cable for 6kV to 35kV Distribution Projects

MV power cable covers common IEC-rated cables from 3.6/6(7.2)kV to 18/30(36)กิโลโวลต์, together with regional and project-specific 35kV-class constructions for distribution, industrial and renewable energy systems.

6–35กิโลโวลต์MV distribution cable systems
Project-EngineeredConstruction matched to network conditions
Underground & IndustrialFeeders, substations and energy routes
ไออีซี / Project SpecMV design and testing framework
XWA MV power cable for 6kV to 35kV distribution projects
MV power cable range for underground distribution, substations and industrial feeder systems.

XWA MV Power Cable

As a medium voltage cable manufacturer, XWA supplies 6kV to 35kV cable constructions for distribution networks, substations, industrial plants and renewable energy collection systems, with copper or aluminum conductors, screened insulation systems, armoring options and sheath materials matched to project specifications.

XWA’s engineering team develops each MV cable construction according to the rated voltage, ขนาดตัวนำ, core arrangement, screen design, armoring requirement, water-blocking condition and installation environment for underground, duct, tray and direct-burial routes.

MV Cable by Voltage Class

Explore distribution cable classes and their product specifications. U0 is the conductor-to-earth rating, U the conductor-to-conductor rating, and Um the highest system voltage for the cable.

The project network voltage, earthing arrangement and fault-clearing time determine the required cable rating. For an 11 kV system, สำรวจ 11kV cable range and its specified U0/U(หนึ่ง) ratings.

North American MV Cable

North American medium voltage cable classes are normally named by nominal system voltage, while IEC cable pages use U0/คุณ(หนึ่ง) การกำหนด. XWA separates these terms so voltage selection, standards discussion and cable construction remain clear.

5กิโลโวลต์, 15กิโลโวลต์, 25kV and 35kV Classes

North American MV Cable covers nominal voltage classes used in utility, ทางอุตสาหกรรม, renewable energy and feeder systems.

Different Naming Basis

IEC pages use U0/คุณ(หนึ่ง), such as 8.7/15(17.5)กิโลโวลต์, while North American schedules commonly use 5kV, 15กิโลโวลต์, 25kV or 35kV class names.

Project Specification Review

XWA reviews conductor, ระดับฉนวน, shield system, jacket, installation route and required standard scope before confirming the cable construction.

Medium Voltage Cable Models

Compare conductor material, ฝัก, water protection and core arrangement across the screened XLPE cable range.

PVC and PE Sheathed Cables

Water-Blocked MV Cables

Halogen-Free and Three-Core Cables

MV power cable is used between low-voltage distribution and high-voltage transmission systems. It supports feeder circuits, สถานีย่อยหม้อแปลงไฟฟ้า, การบริโภคพลังงานทางอุตสาหกรรม, wind and solar collection networks, mining power distribution and municipal underground grids where screened insulation and controlled earthing are required.

XWA produces medium voltage cable in single-core and three-core constructions, including copper wire screened cable, copper tape screened cable, steel wire armoured cable, steel tape armoured cable, aluminum wire armoured cable and water-blocked designs for demanding route conditions.

Distribution Voltage

Common project classes include 3.6/6kV, 6/10กิโลโวลต์, 8.7/15กิโลโวลต์, 12/20กิโลโวลต์, 18/30kV and 26/35kV cable designs.

Screened XLPE System

Manufactured with conductor screen, ฉนวน XLPE, insulation screen and metallic screen layers for stable electric field control.

Installation Options

Factory configurations cover duct, tray, direct burial, tunnel, substation, renewable energy and industrial feeder applications.

MV XLPE Cable Construction

XWA produces medium voltage XLPE cable with a screened insulation system and route-specific mechanical protection. A typical MV cable includes a compacted copper or aluminum conductor, หน้าจอตัวนำ, ฉนวน XLPE, หน้าจอฉนวน, หน้าจอโลหะ, bedding layer, optional armor and an outer sheath selected for the installation environment.

คอนดักเตอร์Compacted copper or aluminium conductors for the selected MV design
Core ArrangementSingle-core, three-core and triplex configurations for MV distribution systems
Insulation Systemหน้าจอตัวนำ, ฉนวน XLPE และหน้าจอฉนวน
หน้าจอเมทัลลิกCopper wires or copper tape, with screen area and bonding matched to the circuit
Armor and Sheathพีวีซี, PE or LSZH sheath; SWA or STA for specified multicore designs, and non-magnetic armour for single-core AC designs

For a wet underground route, we would consider the sheath and water barriers together. A PE jacket protects the outside of the cable, while longitudinal and radial barriers address different paths of moisture entry.

MV XLPE cable construction with single-core and three-core screened cable sections

MV Cable Ratings and Construction Parameters

XWA manufactures medium voltage power cable for distribution and industrial systems from 3.6/6kV to 26/35(40.5)กิโลโวลต์. ไออีซี 60502-2 is normally used for extruded-insulation power cables from 6kV up to 30kV rated voltage classes. สำหรับ 26/35(40.5)kV systems, XWA confirms the applicable project, utility or local specification before finalizing the cable construction.

ระดับแรงดันไฟฟ้าCommon Voltage DesignationApplicable StandardProduct Page
6กิโลโวลต์3.6/6(7.2)กิโลโวลต์ไออีซี 60502-2 project specifications6สายเควี
10กิโลโวลต์6/10(12)กิโลโวลต์ไออีซี 60502-2 project specifications10สายเควี
15กิโลโวลต์8.7/15(17.5)กิโลโวลต์ไออีซี 60502-2 project specifications15สายเควี
20กิโลโวลต์12/20(24)กิโลโวลต์ไออีซี 60502-2 project specifications20สายเควี
30กิโลโวลต์18/30(36)กิโลโวลต์ไออีซี 60502-2 project specifications33สายเควี
35กิโลโวลต์26/35(40.5)กิโลโวลต์Project, utility or local specifications35สายเควี

What Defines the Finished Cable

Conductor area, screen size and core arrangement define the electrical design; sheath and armour determine how the cable fits its route. The finished diameter and mass follow that complete construction.

Current rating is calculated for the actual conductor, laying arrangement, ambient or soil temperature, soil thermal resistivity and circuit spacing. Single-core and three-core constructions retain separate dimensional schedules.
พารามิเตอร์ConfigurationPractical effect
คอนดักเตอร์Copper or aluminium; cross-section specified for the circuitความต้านทาน, การสูญเสีย, termination size and handling weight
การจัดเรียงหลักSingle-core circuits, triplex arrangements or three-core cableRoute space, pulling arrangement and accessories
ฉนวนกันความร้อนXLPE with conductor and insulation screensInsulation thickness follows the rated voltage and product specification
หน้าจอเมทัลลิกWire or tape construction; screen area specified separatelyEarth-fault duty and the bonding arrangement
การป้องกันภายนอกพีวีซี, วิชาพลศึกษา, LSZH; specified armour or water barriersMechanical protection, moisture exposure and fire-performance requirements
Finished dimensionsModel-specific diameter, mass and bending dataDuct clearance, drum planning, pulling and termination fit
Medium Voltage Cable Catalogue PDFDownload XWA medium voltage cable catalogue for voltage classes, construction options and reference product information.
Download PDF
การทดสอบและการควบคุมคุณภาพโรงงานสายเคเบิลแรงดันปานกลาง

Distribution, Substation and Renewable Energy Routes

As an international medium voltage cable manufacturer, XWA focuses on underground distribution circuits, สถานีย่อยหม้อแปลงไฟฟ้า, เครื่องป้อนอุตสาหกรรม, mining power systems, tunnel routes and renewable energy collection networks. Route design can include steel wire armor, steel tape armor, aluminum wire armor, PE sheath, LSZH sheath, semiconductive sheath and water-blocked layers according to mechanical, environmental and earthing requirements.

Medium voltage cable production is arranged around cable construction, dimensional control, การอัดขึ้นรูปฉนวน, screen continuity, sheath integrity and routine testing records within the agreed project scope.

MV Cable Engineering Resources

Explore the details behind screen design, installation routes and factory testing.

Screen bonding

Single-point, both-end and cross-bonding arrangements for metallic screens.

Underground routes

How route conditions influence the sheath, water protection and installation design.

Partial discharge testing

What the test checks and how the test record supports cable inspection.

Related cable ranges: low voltage power cable, สายไฟฟ้าแรงสูง, submarine cable.

Medium Voltage Cable Questions

What is MV power cable?

MV power cable is an insulated medium voltage cable system used for electrical distribution between low-voltage equipment and high-voltage transmission networks. It commonly includes a conductor, หน้าจอตัวนำ, ฉนวน XLPE, หน้าจอฉนวน, หน้าจอโลหะ, bedding, เกราะเสริมและปลอกด้านนอก.

What voltage range does XWA MV power cable cover?

XWA manufactures common medium voltage cable classes from 3.6/6(7.2)kV to 26/35(40.5)กิโลโวลต์, including 6kV, 10กิโลโวลต์, 11กิโลโวลต์, 15กิโลโวลต์, 20กิโลโวลต์, 30กิโลโวลต์, 33kV and 35kV distribution systems.

Which standard applies to MV XLPE power cable?

ไออีซี 60502-2 is normally used for extruded-insulation medium voltage power cable through 18/30(36)กิโลโวลต์. สำหรับ 26/35(40.5)kV systems, XWA confirms the applicable project, utility or local specification before production.

Are IEC 15kV and North American 15kV cable ratings the same?

IEC schedules identify U0/U(หนึ่ง), for example 8.7/15(17.5)กิโลโวลต์. North American 15kV class specifications also use an insulation level and their applicable product standard. The nominal class name alone does not establish the same cable construction or rating.

What MV cable constructions are available?

XWA supplies single-core and three-core MV cable constructions with copper or aluminum conductors, copper tape or copper wire screens, พีวีซี, PE or LSZH sheaths and armored or unarmored options.

How do N2XS2Y, N2XS(เอฟ)2Y and N2XS(ฟลอริด้า)2Y differ?

N2XS2Y uses a PE outer sheath. N2XS(เอฟ)2Y adds longitudinal water blocking, while N2XS(ฟลอริด้า)2Y combines longitudinal blocking with a radial moisture barrier. The route moisture conditions determine which protection is appropriate.

How does XWA control MV cable production quality?

XWA prepares MV cable production with conductor preparation, triple extrusion where applicable, screen application, armoring, sheath extrusion, dimensional checks, voltage testing and routine test records according to the agreed specification.

How does XWA prepare MV cable offers?

XWA reviews voltage designation, วัสดุและขนาดของตัวนำ, core count, screen type, armor, sheath material, installation route, standard and drum length before preparing the cable construction and offer.

Contact XWA for MV Cable Projects

XWA prepares MV cable offers around voltage class, วัสดุตัวนำ, core construction, screen type, armor, sheath design and required standard, with cable construction matched to the confirmed project specification.

Voltage classes: 3.6/6kV to 26/35(40.5)กิโลโวลต์ การก่อสร้าง: XLPE insulated screened MV power cable การใช้งาน: การกระจาย, substation, industrial and renewable energy systems

    รับใบเสนอราคาฟรีได้ที่ 24 ชั่วโมง

    อีเมล*:

    ชื่อ*:

    ประเทศของคุณ:

    โทร*:

    ความต้องการของคุณ*: