Explore cable structures by armour, electrical screens, izolim, këllëf, conductor and protective layers. These construction choices span voltage classes: one cable can combine several of them.

A useful starting point is the job each layer needs to do: armour for mechanical protection, screens for electrical duty, and sheath materials for the route environment. We recommend comparing those functions together, because an extra protective layer also affects cable diameter, mass and installation. The combinations below connect these choices to relevant XWA cable ranges.

Discuss a cable construction

Find cables by construction

Browse armoured, screened, unarmoured, halogen-free and water-blocked constructions. A project cable can combine several features to meet its electrical duty and route conditions.

01

Armoured cable constructions

Three-core LV cable section with copper conductors, Izolimi XLPE, fillers, Shtrati PVC, steel wire armour and PVC sheath.
Three-core LV cable section with copper conductors, Izolimi XLPE, fillers, Shtrati PVC, steel wire armour and PVC sheath.

XLPE/SWA/PVC

Izolimi XLPE, steel wire armour and PVC sheath for fixed power routes. Dirigjent, core count and electrical screens are selected for the voltage and application.

Armour details

CU/XLPE/PVC/SWA/PVC

Përçues bakri, Izolimi XLPE, Shtrati PVC, steel wire armour and PVC sheath: a common LV armoured construction.

Request this construction

AL/XLPE/PVC/SWA/PVC

Aluminium conductor, Izolimi XLPE, Shtrati PVC, steel wire armour and PVC sheath, with core arrangement and section selected for the circuit.

Request this construction

CU/XLPE/CTS/PVC/SWA/PVC

A screened, steel-wire-armoured multicore power construction. CTS identifies copper tape screens; MV designs also require conductor and insulation semiconductive screens.

Screened armour details

CU/XLPE/CTS/PVC/AWA/PVC

Screened single-core AC cable with aluminium wire armour, used where integral mechanical protection and non-magnetic armour are required.

Single-core armour details
02

Screened cable constructions

Screened MV cable section with semiconductive layers, ekran me tela bakri, separation tape and PE sheath.
Screened MV cable section with semiconductive layers, ekran me tela bakri, separation tape and PE sheath.

CU/XLPE/CWS/PVC

Përçues bakri, Izolimi XLPE, copper wire screen and PVC sheath. The N2XSY range on this site uses this screened construction.

N2XSY cable

AL/XLPE/CWS/PVC

Aluminium conductor, Izolimi XLPE, copper wire screen and PVC sheath. The metallic screen is separate from the aluminium phase conductor.

NA2XSY cable

CU/XLPE/CWS/PE

Përçues bakri, Izolimi XLPE, copper wire screen and PE sheath. Screen area, sheath properties and voltage remain separate specification items.

N2XS2Y cable

AL/XLPE/CWS/PE

Aluminium phase conductor with a separate copper wire screen, XLPE insulation and PE sheath.

NA2XS2Y cable

CU/XLPE/CTS/PVC

Copper conductor with XLPE insulation, copper tape screens and PVC sheath. The N2XSEY example is a three-core screened construction without SWA.

N2XSEY cable

CU/PVC/TCWB/PVC

Copper conductors, Izolimi PVC, an overall tinned copper wire braid and PVC sheath. Braid coverage and core arrangement are selected for the control or signal duty.

Control and signal screen details
03

Unarmoured insulated constructions

Unarmoured three-core LV cable section with copper conductors, Izolimi XLPE, fillers and PVC sheath.
Unarmoured three-core LV cable section with copper conductors, Izolimi XLPE, fillers and PVC sheath.

CU/PVC/PVC

Përçues bakri, Izolim PVC dhe këllëf PVC. The NYY-J example includes a protective conductor; the suffix and full datasheet define the core identification.

NYY-J cable

CU/XLPE/PVC

Përçues bakri, XLPE insulation and PVC sheath, as used in the unarmoured N2XY construction.

N2XY cable
04

Halogen-free sheath constructions

Screened MV cable section with a halogen-free flame-retardant sheath.
Screened MV cable section with a halogen-free flame-retardant sheath.

CU/XLPE/HFFR

Përçues bakri, XLPE insulation and halogen-free flame-retardant sheath, as represented by N2XH. Project fire requirements define the applicable smoke, gas and flame tests.

Kabllo N2XH

CU/XLPE/CWS/HFFR

Përçues bakri, screened XLPE insulation, copper wire screen and halogen-free sheath, as represented by N2XSH.

N2XSH cable
05

Water-blocked screened constructions

Cable section showing screen-region water-blocking tapes and a radial laminate barrier.
Cable section showing screen-region water-blocking tapes and a radial laminate barrier.

CU/XLPE/CWS/PE + longitudinal blocking

Screened PE-sheathed cable with longitudinal water-blocking components in the screen region. Conductor water blocking can be specified separately.

N2XS(F)2Y cable

AL/XLPE/CWS/PE + longitudinal blocking

Aluminium-conductor screened cable with PE sheath and longitudinal water blocking in the specified region.

NA2XS(F)2Y cable

CU/XLPE/CWS/PE + longitudinal and radial barriers

A screened construction combining longitudinal blocking with a radial laminate barrier. This is a different barrier arrangement from a longitudinal-only construction.

N2XS(FL)2Y cable

Materials and layer reference

Forca të blinduara, ekranet, izolim, conductors and protective layers

Read the layers from the conductor outwards: CU = copper; AL = aluminium; CWS = copper wire screen; CTS = copper tape screen; TCWB = tinned copper wire braid; SWA = steel wire armour; AWA = aluminium wire armour; HFFR = halogen-free flame-retardant material.

Materialet, layers and construction details

The following reference explains the individual layers behind these combinations. Forca të blinduara, ekranet, izolim, këllëfët, përçuesit, rregullimi thelbësor, barrierat ujore dhe performanca e zjarrit can be combined within one project specification.

One Cable, Several Structural Choices

Armour protects mechanically; insulation separates electrically; screens perform electrical duties; the sheath protects the assembly. These layers work together in the finished cable design.

Për shembull, a three-core distribution cable can have copper conductors, Izolimi XLPE, semiconductive layers, copper tape screens, an inner sheath, steel wire armour and a PVC outer sheath. It belongs to several structure groups at once.

This directory complements Llojet dhe modelet e kabllove. The complete cable specification defines rated voltage, dimensionet, tests and installation conditions. Available configurations depend on the agreed electrical and mechanical design.

Real three-core power cable sample showing stranded copper conductors, insulation and metallic tape layers
Three-core power cable sample with visible metallic tape layers.
01

Armoured Cables

6 construction distinctions

Armour is a mechanical-protection layer, independent of the insulation material and voltage class. Its material and geometry also affect mass, përkulje, terminations and electrical losses.

Steel wire armour (SWA)Round steel wires around the cable assembly
Common around multicore power and control cables; screened MV constructions can also include SWA.
Armatura me tela alumini (AWA)Non-magnetic aluminium wires
Often used for single-core AC power cables to avoid the magnetic-loss issue of ordinary steel around one phase.
Steel tape armour (STA / DSTA)One or more specified layers of steel tape
A different protective geometry from wires; tensile duty and installation limits require the declared design.
Wire braid protectionInterwoven metallic wires
Mechanical braid and an electrical screening braid are not automatically the same component or duty.
Special tensile armourOne or more designed armour layers
Submarine and other special-service cables need dedicated load, lodhje, corrosion and system qualification.
Unarmoured constructionNo integral mechanical armour
Kanalet, trays or other external protection may suit the route; electrical screens may still be present.

Single-core AC circuits commonly use non-magnetic armour to limit magnetic losses and heating. Armour earthing and any protective-conductor function are designed for the circuit fault duty.

Cut end of a four-core copper cable showing coloured core insulation and a ring of armour wires
Four-core cable cross-section with copper conductors and steel wire armour.
Back to structure categories
02

Screened and Shielded Cables

6 construction distinctions

Electrical screens perform different jobs in power and signal cables. In MV/HV insulation systems, semiconductive screens control the electric field; the metallic screen is a separate layer. Control and instrumentation screens address electromagnetic interference.

Semiconductive conductor / insulation screensSmooth the electrical interfaces around power-cable insulation
Not a substitute for a metallic screen, armour or an insulating layer.
Ekran me tela bakri (CWS)Metallic wires around a screened power core
Screen area, detyrë faji, bonding and accessories form part of the electrical specification.
Ekran me shirit bakri (CTS)Metallic tapes around the insulated power core
Tape layout and electrical duty differ from a copper wire screen; substitution needs a design check.
Braid screenInterwoven conductive wires around a core group or assembly
Coverage, termination and frequency-dependent performance matter; a braid is not automatically armour.
Foil screen and drain wireConductive foil with a defined connection path
Used in many signal constructions; continuity and termination govern the completed screen.
Individual and overall screensScreens around pairs/triads, around the complete assembly, or both
Individual screens separate groups; an overall screen surrounds the laid-up groups.

A cable can combine electrical screens and mechanical armour. The screen arrangement follows the electrical duty, while the armour follows the route-protection requirement.

Cable cutback showing four separately wrapped conductor groups inside a green outer sheath
Individually wrapped conductor groups demonstrate how screening can be applied below the overall cable sheath.
Back to structure categories
03

Insulation Materials

5 construction distinctions

Insulation surrounds the conductor and provides the required electrical separation. The same material name can appear in different voltage designs; compound, trashësia, screens and testing define the complete insulation system.

Izolimi XLPEPolietileni i ndërlidhur
Used across power-cable voltage classes; XLPE alone does not establish current rating or the outer-sheath material.
Izolimi PVCPolyvinyl chloride compound around the conductor
Used in specified LV and control constructions; distinguish PVC insulation from a PVC outer sheath.
EPR / HEPR insulationEthylene-propylene rubber-based insulation
Used in selected power and flexible-duty designs; operating and mechanical limits follow the declared compound.
PE insulationPolyethylene insulation
Common in selected signal and other cable designs; an external PE jacket is a different layer.
Cross-linked halogen-free compoundsA defined halogen-free polymer system
Used in relevant PV and other constructions; compound and cable fire tests still need the declared scope.

Temperature limits and current ratings follow the product datasheet and installation conditions for the complete cable.

Back to structure categories
04

Outer Sheaths and Environmental Protection

5 construction distinctions

The outer sheath protects the cable from its environment. Compound selection addresses the moisture, weathering and mechanical exposure of the route.

PVC sheathPolyvinyl chloride outer protection
Flame, vaj, UV and chemical performance depend on the specified compound and test evidence.
Mbulesa PEPolyethylene outer protection
Used in many buried power designs; ordinary PE is not automatically flame-retardant or a complete water barrier.
LSZH / LSOH sheathLow-smoke, halogen-free compound system
Smoke and halogen properties require defined tests; LSZH does not itself mean circuit integrity during fire.
Rubber / elastomer sheathDeclared elastomeric protective compound
Flexing, vaj, moti, abrasion and immersion suitability follow the actual cable duty and compound.
Metallic sheath or laminateA continuous metal layer or bonded laminate
May provide moisture protection and electrical functions; korrozioni, bonding and joints require system design.

UV, vaj, termite and immersion requirements are specified with the corresponding compound and test requirements.

Back to structure categories
05

Conductor Materials and Stranding

6 construction distinctions

The phase conductor carries load current. Materiali përcjellës, stranding and shape are separate from screen and armour material: an aluminium-conductor cable can have a copper screen, and a copper-conductor cable can have aluminium armour.

Copper conductorsPlain or tinned copper, as specified
Zona, rezistencës, stranding and terminal compatibility define the required conductor.
Alumini / aluminium-alloy conductorsAluminium or a specified alloy
Alloy, electrical resistance, connections and mechanical duty distinguish the construction.
Solid and stranded conductorsKlasa 1 solid and Class 2 stranded conductors for insulated cables
Conductor class describes the construction; it is not a blanket installation-flexibility approval.
Flexible fine-stranded conductorsKlasa 5 ose Klasa 6 flexible copper conductors, where specified
Repeated movement, torsion, trailing service or drag-chain use require the complete cable to be rated for that duty.
Round, compacted and sector-shaped conductorsDifferent conductor geometries
Shape changes assembly dimensions and accessory fit; equal nominal area does not mean equal cable diameter.
Steel-reinforced bare conductorsAluminium strands around a steel strength member
The steel core in ACSR is reinforcement within the conductor, not cable armour outside insulation.

AAC, AAAC and ACSR are bare conductors for overhead lines; sheathed power cables serve underground and other insulated routes.

Back to structure categories
06

Core Count and Cable Arrangement

6 construction distinctions

A three-core cable places the phase cores inside a common sheath. Three separate single-core cables allow a selected flat or trefoil layout, with different handling, bonding and support arrangements.

Kabllo me një bërthamëOne principal insulated power conductor per cable
Power circuits use the specified arrangement of separate cables; armour and bonding need the corresponding design.
Multicore power cableSeveral insulated power cores under a common sheath
Core count, neutral and protective-conductor arrangements must be explicit.
Three-core screened cableThree screened phase cores in one assembly
Screen layout, fillers and common outer layers distinguish it from three individual single-core cables.
Multicore control cableMultiple identified control conductors
Numbering, colour identification, protective conductor and screen arrangement follow the stated design.
Pairs, triads and grouped signalsConductors assembled into defined signal groups
Group twist, individual/overall screens and electrical characteristics are specified together.
Aerial bundled assemblyInsulated conductors assembled for overhead duty
Lajmëtar, neutral and phase arrangements follow the utility design; ABC is not a burial-cable construction.

The notation 3 x 1 x 240 identifies three separate single-core 240 mm2 cables. Metallic-screen area is stated separately from phase-conductor area.

Back to structure categories
07

Water Blocking and Moisture Barriers

5 construction distinctions

Conductor water blocking, screen-region blocking and radial barriers protect different moisture paths. Marine installations require a dedicated cable and accessory design.

Longitudinal screen-region blockingShirita të fryrë, yarns or other specified components
Restricts water travel along the screened region after entry; it is not a radial metallic barrier.
Water-blocked conductorA specified barrier within the conductor assembly
Addresses a separate longitudinal path from the screen-region construction.
Radial laminate barrierBonded metal/polymer barrier beneath or within the sheath system
Addresses radial moisture entry; layer continuity, joints and terminations affect the completed system.
Metallic moisture sheathA defined continuous metallic sheath
Materiali, mbrojtje nga korrozioni, electrical duty and accessory seals need the complete system specification.
Submarine protective systemDedicated barriers, sheath protection and armour
Water pressure, installation loads, fatigue and route conditions require a separate submarine design.

Longitudinal barriers limit water travel along the specified cable region; radial barriers reduce moisture ingress through the cable circumference. End seals protect cable lengths during storage and installation.

Back to structure categories
08

Fire Barriers and Declared Fire Performance

5 construction distinctions

Fire-performance specifications address flame spread, tymi, combustion gases or circuit integrity. Fire-barrier layers are selected to support the required tested performance.

Flame-retardant constructionLimits flame propagation under the specified test
Single-cable and bunched-cable tests address different conditions.
Low-smoke constructionControls smoke under the stated test method
Low smoke is not equivalent to low halogen emissions or continued electrical operation.
Halogen-free compound systemMeets the relevant declared halogen / gas test requirements
An LSZH marking is not a universal product approval or a circuit-integrity classification.
Circuit-integrity / fire-resistant constructionMaintains the tested electrical function under specified fire conditions
Tensioni, rregullimi i testit, duration and any shock or water exposure belong to the claim.
Mica or other declared fire barrierAn additional material layer in certain designs
Its presence alone does not prove that the completed cable passes a circuit-integrity test.

IEC 60332, IEC 61034, IEC 60754 dhe IEC 60331 address different aspects. Only the applicable part, botim, test conditions and actual evidence establish the declared performance.

Back to structure categories

Related models and project ranges

Published cable models and application ranges

Related cable models and construction examples

Compare the conductor, izolim, screen and sheath combinations used in the related cable models below.

NYY-J

CU/PVC/PVC

Bakri, Izolim PVC dhe këllëf PVC

N2XY

CU/XLPE/PVC

Bakri, XLPE insulation and PVC sheath

NA2XSY

AL/XLPE/CWS/PVC

Aluminium phase conductor, ekran me tela bakri, PVC sheath

N2XS2Y

CU/XLPE/CWS/PE

Copper phase conductor, ekran me tela bakri, Mbulesa PE

N2XSEY

CU/XLPE/CTS/PVC

Three screened copper phase cores in a common PVC sheath

Armoured construction options

XLPE / shtroja / SWA / PVC

Insulated core assembly, steel wire armour and PVC sheath; electrical screens are added for the specified voltage design

N2XSH

XLPE / ekran metalik / halogen-free sheath

Screened power cable with a declared halogen-free sheath system

N2XS(F)2Y

Screen-region blocking + Mbulesa PE

Longitudinal blocking around the screened core

N2XS(FL)2Y

Longitudinal blocking + radial laminate + PE

Separate barriers for longitudinal and radial moisture paths

The construction drawing brings together conductor class, shtroja, fillers, zona e ekranit, armour dimensions and moisture barriers in one layer sequence.

Product Ranges by Project Duty

Screened Distribution Feeders

Insulation systems, ekrane metalike, route protection and accessory interfaces for medium-voltage distribution.

Explore the range

High-Voltage Cable Systems

Izolimi, këllëf ose ekran metalik, moisture barriers and bonding assessed as one cable system.

Explore the range

Submarine Power Routes

Purpose-designed water protection, tensile armour and mechanical duty for the specified marine installation.

Explore the range

Flexible Industrial Supply

Flexible industrial cables combine suitable conductor stranding, insulation and sheath materials for the specified movement and environment.

Explore the range

Control and Instrumentation

Core groups, identification and individual/overall shielding configured for the signal function.

Explore the range

Overhead Conductors and Assemblies

Bare conductor reinforcement and insulated aerial assemblies, distinct from underground armour systems.

Explore the range

Standards and technical reading

Scope, specifications and further construction guidance

Standards Follow the Finished Construction

IEC 60228 covers conductors, while IEC 60502-1 dhe IEC 60502-2 address their respective LV and MV power-cable ranges. Higher-voltage systems use the applicable cable-system standard and accessory requirements.

Të official publication scope describes the MV standard coverage for fixed distribution installations.

Current rating, diametri, masë, bending limits and drum requirements are provided for the selected finished construction.

Further Construction Guidance

For electrical and mechanical differences, read steel wire armour in MV cable. For route protection and installation trade-offs, shih armoured versus unarmoured MV cable.

Cable Structure Questions

Can an armoured cable also be screened?

po. A metallic screen and mechanical armour are separate components. A screened MV cable can also have steel wire armour; the screen duty, armour arrangement and bonding must each match the design.

Does a structure name determine the voltage class?

XLPE, SWA, PVC and PE identify materials or layers. The rated voltage, dimensionet e izolimit, screens and test requirements define the electrical design.

Is LSZH the same as fire-resistant cable?

LSZH describes smoke and halogen-related properties. Fire-resistant cable is designed and tested to maintain circuit operation under specified fire conditions.

How is a project construction selected?

Tensioni, madhësia e përcjellësit, core arrangement and route conditions define the construction. XWA works from the project specification or cable schedule to establish the manufacturing and test requirements.