N2XSEY Cable

N2XSEY cable is a three-core medium-voltage power cable with stranded copper conductors, screened XLPE insulation and a common PVC outer sheath. Three phase cores form one assembled cable for fixed distribution.

The reference CU/XLPE/CTS/PVC construction uses metallic screening but no armour. The shared sheath distinguishes it from a circuit of three separate single-core cables and changes handling mass, cable-entry dimensions and installation geometry.

Concept illustration of three individually screened copper cores within a common PVC cable sheath
Three screened copper cores inside one PVC sheath. Ilustracija koncepta, not to scale.

IZGRADNJA

Conductors
Three stranded copper phase conductors
Insulated cores
Semiconductive screens and XLPE insulation
Metalni ekrani
Copper tape screening in the reference construction
Assembly
Filler and common PVC sheath; unarmoured

KARAKTERISTIKE

Referentni napon
12/20 kV for the displayed dataset
Core layout
Three screened cores in one cable body
Termička referenca
90°C maksimalna radna temperatura provodnika u dizajnu izvora
Standardni kontekst
IEC 60502-2 and relevant VDE/HD project requirements

N2XSEY for Fixed Power Distribution

Voltage, Veličina provodnika/ekrana i uslovi rute definišu konfiguraciju projekta.

Zatražite ponudu

N2XSEY Cable Technical Data

Preporučeni referentni podaci: objavljene vrijednosti za preliminarnu usporedbu. Konačne dimenzije isporuke, ocjene i raspon veličina slijede dogovoreni XWA tehnički list.

Veličina kabla
(mm²)
DC otpor
20°C (Ω/km)
Pribl. OF
(mm)
Pribl. masa
(kg/km)
Vazduh
(A)
Ground
(A)
3 x 95/160.193067.06900326316
3 x 150/250.124074.59250426404
3 x 185/250.099178.510650488457
3 x 240/250.075485.013000576532
3 x 300/250.060190.015250654599
3 x 400/350.047098.019100750685

Three-core CU/XLPE/CTS/PVC, 12/20 kV. Diameter and mass refer to the assembled cable; the slash notation identifies the separately specified metallic-screen section.

Referentni kapacitet: one system; zrak 30°C, faktor opterećenja 1.0; tlo 20°C, dubina 0.7 m, toplotna otpornost 1.0 K·m/W, faktor opterećenja 0.7. Reference conductor limit: 90°C. Continuous full-load burial requires a rating calculated at load factor 1.0.

Three-core construction and accessory interfaces

N2XSEY assembles the three phase cores within a common sheath. Separate single-core cables permit flat or trefoil formation; each arrangement has its own current-rating, handling and support requirements.

Termination stress-control components fit the insulation diameter and screen treatment. Glands and entry seals fit the complete cable diameter. The 3×240/25 reference is approximately 85 mm in diameter and 13 kg/m, before drum tare; handling calculations therefore use assembly mass, not copper mass alone.

Schematic of three individually screened copper cores, XLPE izolacija, filler and common PVC sheath
Three screened cores share one outer sheath; the drawing is explanatory and not to scale.
Diagram separating cable voltage designation from insulation diameter and overall diameter for accessory fit
Raskid, joint and gland selection follows the insulation diameter, screen arrangement and finished cable diameter.

Primjena i uvjeti instalacije

Industrijska distribucija, substation connections and suitable underground or ducted feeders can use this combined three-core assembly. Prečnik kabla, mass and bending limits inform route access and pulling equipment. Routes requiring armour, water blocking or enhanced fire performance use the corresponding construction.

The manufacturing specification defines screens, insulation and sheath thicknesses, accessory dimensions and tests for the three-core assembly. The official standard scope opisuje okvir fiksnog distributivnog kabla.

N2XSEY and Related Constructions

ModelGlavna razlika
N2XSY single-core cableEach phase cable has its own sheath; circuit geometry and bonding need separate assessment.
20 kV opseg kablovaVoltage-class context for 12/20(24) kV projects, rather than an exact three-core model.
Armoured MV constructionMechanical armour adds a separate layer and changes the specified design and dimensions.

N2XSEY Cable FAQs

Does N2XSEY mean the cable is armoured?

The reference N2XSEY construction is screened and unarmoured. Its metallic screen performs an electrical duty; mechanically protected variants add a separate armour layer.

Can 12/20 kV dimensions be used for a 6/10 kV variant?

The table covers the stated 12/20 kV construction. A 6/10 kV version uses its own insulation dimensions and construction-specific rating data.

Is N2XSEY the same as three N2XSY cables?

N2XSEY combines three phase cores inside a common sheath. Three N2XSY cables are separately sheathed single-core products, with different handling and installation arrangements.