N2XS2Y Cable

N2XS2Y Cable je jednožilni srednjenaponski energetski kabel sa upletenim bakrenim provodnikom, XLPE izolacija, copper wire screen and polyethylene outer sheath.

The designation is used for fixed medium-voltage distribution where a PE-sheathed cable is preferred for underground, water-exposed, outdoor, duct and demanding utility routes. Uobičajene klase napona projekta uključuju 6/10 kV, 8.7/15 kV, 12/20 kV i 18/30 kV prema IEC i VDE specifikacijama.

XWA supplies N2XS2Y as a project cable configuration where conductor size, bakarni presek ekrana, klasa napona, PE sheath requirement, ispitni dokumenti i izvozno pakovanje su usklađeni sa rasporedom kablova i odredišnim tržištem.

N2XS2Y Cable

IZGRADNJA

Dirigent:

Klasa 2 bakreni provodnik, okruglo zbijeno gdje je navedeno

Izolacija:

XLPE izolacija sa unutrašnjim i vanjskim poluvodljivim ekranima

Metalik ekran:

Ekran od bakrene žice sa kontra spiralom; sekcija ekrana odabrana prema zahtjevu struje kvara

Outer Sheath:

Polyethylene outer sheath, commonly black; MDPE or HDPE direction follows the project specification

KARAKTERISTIKE

Voltage Classes:

6/10 kV, 8.7/15 kV, 12/20 kV i 18/30 kV projektne klase

Temperatura provodnika:

XLPE srednjenaponski dizajni obično koriste 90°C maksimalna temperatura provodnika u normalnom radu

Instalacija:

Fiksna instalacija u zatvorenom prostoru, na otvorenom, u kanalima i na podzemnim putevima sa odgovarajućim mehaničkim i termičkim dizajnom

STANDARDI:

Uobičajene reference uključuju IEC 60502-2, VDE 0276-620, IEC 60228 i IEC 60332-1-2. Standardna referenca nije tvrdnja o certifikaciji.

N2XS2Y Medium Voltage Cable for Utility and Industrial Networks

XWA proizvodi srednjenaponske kablovske konfiguracije za distributivne mreže, trafostanice, putevi obnovljive energije i industrijski dovodnici.

N2XS2Y Cable Technical Data

Preporučeni referentni podaci: N2XS2Y is normally a single-core screened medium-voltage cable. Format veličine ispod je poprečni presjek vodiča / presjek bakrenog ekrana u mm2.

Vrijednosti kapaciteta su referentne vrijednosti za jedno jednožilno kolo u zraku na 30°C with load factor 1.0 and three-cable bunching, or in ground at 20°C with load factor 0.7 and three-cable bunching. Konačna vrijednost struje projekta ovisi o toplinskoj otpornosti tla, dubina ukopa, razmak, grupisanje, vezivanje omotača, temperatura rute i lokalni metod proračuna. Konačne XWA proizvodne dimenzije i testne vrijednosti slijede odobreni list s podacima o ponudi.

N2XS2Y 6/10 kV Preporučeni podaci

Klasa naponaVeličina kablaOtpor provodnika na 20 C (ohm/km)Debljina izolacije (mm)PE sheath thickness (mm)Pribl. OF (mm)Pribl. težina (kg/km)Kapacitet u vazduhu 30 C (A)Kapacitet u tlu 20 C (A)
6/10 kV1 x 35/160.5243.42.524900197187
6/10 kV1 x 50/160.3873.42.525950236220
6/10 kV1 x 70/160.2683.42.5271200294268
6/10 kV1 x 95/160.1933.42.5281450358320
6/10 kV1 x 120/160.1533.42.5301700413363
6/10 kV1 x 150/250.1243.42.5312050470409
6/10 kV1 x 185/250.09913.42.5332400535456
6/10 kV1 x 240/250.07543.42.5352950631526
6/10 kV1 x 400/350.04703.42.5414500827662

N2XS2Y 12/20 kV Preporučeni podaci

Klasa naponaVeličina kablaOtpor provodnika na 20 C (ohm/km)Debljina izolacije (mm)PE sheath thickness (mm)Pribl. OF (mm)Pribl. težina (kg/km)Kapacitet u vazduhu 30 C (A)Kapacitet u tlu 20 C (A)
12/20 kV1 x 35/160.5245.52.528970200189
12/20 kV1 x 50/160.3875.52.5291150239222
12/20 kV1 x 70/160.2685.52.5311350297271
12/20 kV1 x 95/160.1935.52.5321650361323
12/20 kV1 x 120/160.1535.52.5341900416367
12/20 kV1 x 150/250.1245.52.5352250470409
12/20 kV1 x 185/250.09915.52.5372600538461
12/20 kV1 x 240/250.07545.52.5403200634532
12/20 kV1 x 400/350.04705.52.5454750829671

N2XS2Y 18/30 kV Preporučeni podaci

Klasa naponaVeličina kablaOtpor provodnika na 20 C (ohm/km)Debljina izolacije (mm)PE sheath thickness (mm)Pribl. OF (mm)Pribl. težina (kg/km)Kapacitet u vazduhu 30 C (A)Kapacitet u tlu 20 C (A)
18/30 kV1 x 50/160.3878.02.5341350241225
18/30 kV1 x 70/160.2688.02.5361600299274
18/30 kV1 x 95/160.1938.02.5371900363327
18/30 kV1 x 120/160.1538.02.5392150418371
18/30 kV1 x 150/250.1248.02.5402550472414
18/30 kV1 x 185/250.09918.02.5422900539466
18/30 kV1 x 240/250.07548.02.5443500635539

N2XS2Y Cable Construction

N2XS2Y is built around a stranded copper conductor with an extruded conductor screen, XLPE izolacija i izolacijski ekran primijenjen kao dio srednjenaponskog izolacionog sistema. Ekran od bakrene žice i kontra spirala obezbeđuju metalnu putanju ekrana, followed by a polyethylene outer sheath.

Jednojezgrena konstrukcija je važna. Trenutni rejting, lepljenje ekrana, inducirani napon plašta, radijus savijanja i dizajn završetaka se procjenjuju drugačije od trožilnog SN kabela. Kada tender zahteva trožilni ekranizovani kabl, N2XSEY ili neka druga trojezgrena oznaka bi se mogla bolje slagati.

The copper screen section, obično prikazan kao drugi broj u veličini kao što je 1 x 240/25 mm2, odabire se prema struji zemljospoja i dizajnu zaštite. Nije dekorativno i mora odgovarati zahtjevima za struju kvara sistema.

Applications for N2XS2Y Medium Voltage Cable

N2XS2Y cable is used in medium-voltage distribution networks where a screened single-core cable with PE sheath is accepted by the project specification. Common routes include transformer stations, rasklopne stanice, elektrane, industrijske hranilice, mreže za prikupljanje obnovljive energije i kola za distribuciju komunalnih usluga.

Kabl se može instalirati u zatvorenom prostoru, na otvorenom, in ducts, in water and in ground routes when the installation design accounts for mechanical protection, povlačenjem napetosti, radijus savijanja, temperatura rute i trenutna ocjena. The PE sheath supports stronger mechanical and moisture-resistance positioning than a conventional PVC sheath.

The PE sheath is not normally treated as a flame-retardant sheath under flame-test definitions used for PVC-sheathed cable. Za tunele, public buildings or routes requiring flame-retardant or low-smoke halogen-free performance, another MV cable design may be required.

N2XS2Y vs N2XSY, NA2XS2Y and N2XS(F)2Y

N2XS2Y and N2XSY share copper conductor, XLPE insulation and screened single-core MV cable logic, but the outer sheath differs. N2XSY koristi PVC plašt; N2XS2Y uses PE sheath for routes where mechanical durability, water exposure or underground service is a stronger requirement.

NA2XS2Y is the aluminium-conductor companion to N2XS2Y. It can reduce conductor cost and weight, but conductor size, otpor, termination design and short-circuit performance are different from copper N2XS2Y.

N2XS(F)2Y adds a longitudinal water-blocking construction detail. It should not be treated as identical to standard N2XS2Y unless the project specification requires the `(F)` water-blocking layer and XWA confirms that construction.

ModelGlavna razlikaTipična uloga stranice
N2XSYCopper conductor with PVC sheathPVC-sheath comparison
N2XS2YCopper conductor with PE sheathOva stranica
NA2XS2YAluminium conductor with PE sheathSljedeća prateća stranica
N2XS(F)2YCopper conductor with PE sheath and longitudinal water blockingZasebna varijanta blokirana vodom

Testiranje, Dokumenti i izvozno pakovanje

N2XS2Y production documentation can include the approved datasheet, provjere otpornosti provodnika, zapisi o ispitivanju napona, zapisi o ispitivanju djelomičnog pražnjenja, dimenzionalni pregled, raspored bubnjeva, lista pakovanja i fotografije proizvoda. Testovi tipa, dokazi o ispitivanju plamena ili inspekcija treće strane dodaju se samo kada to zahtijeva projekt i kada su dostupni za tačnu konstrukciju.

Izvozno pakovanje se obično planira prema težini kabla, dužina bubnja, maksimalni prečnik bubnja, rukovanje rutom i utovar kontejnera. Srednjenaponski jednožilni kabel može postati težak na velikim poprečnim presjecima, tako da je dužina bubnja dio tehničkog i logističkog pregleda, ne samo preferencija dostave.

Za citat, XWA treba oznaku modela, klasa napona, veličina provodnika, bakarni presek ekrana, ruta instalacije, standard, količina, željena dužina bubnja, odredišnu zemlju i potrebne dokumente. Informacije se koriste za potvrdu konfiguracije kabla i izdavanje ponude specifične za projekat.

N2XS2Y Cable FAQs

What is N2XS2Y Cable?

N2XS2Y Cable is a screened single-core medium-voltage power cable with a copper conductor, XLPE izolacija, copper wire screen and polyethylene outer sheath. Koristi se za fiksne SN distributivne rute u komunalnom sektoru, trafostanica, industrijskih i proizvodnih sistema.

Common N2XS2Y voltage classes include 6/10 kV, 8.7/15 kV, 12/20 kV i 18/30 kV. Raspored projektnog kabla definira potrebnu Uo/U naponsku klasu i zahtjeve za ispitnim naponom.

Tipična konstrukcija je Class 2 bakreni provodnik, ekran provodnika, XLPE izolacija, izolacioni ekran, copper wire metallic screen with counter helix and PE outer sheath. The screen section and sheath material are specified by the project.

N2XS2Y is normally a single-core medium-voltage cable. Zahtjeve za trožilni SN treba posebno provjeriti zbog dizajna kabela, raspored ekrana, radijus savijanja i pribor su različiti.

U veličini kao što je 1 x 240/25 mm2, 240 mm2 je poprečni presjek bakrenog vodiča i 25 mm2 je poprečni presek bakrenog ekrana. Vrijednost ekrana mora odgovarati funkciji zemljospoja i dizajnu zaštite.

N2XS2Y is used in transformer stations, rasklopne stanice, elektrane, industrijske distributivne mreže, kola za prikupljanje obnovljive energije, cable ducts and underground utility routes where PE-sheathed MV cable is accepted.

N2XS2Y koristi PE vanjski omotač. N2XSY koristi vanjski omotač od PVC-a. PE sheath can be preferred for underground, water-exposed or mechanically demanding routes, while PVC sheath remains common where flame behaviour, rukovanje ili konvencija projekta ukazuje na PVC.

N2XS(F)2Y adds longitudinal water-blocking layers around the metallic screen area. Standard N2XS2Y should not be described as an `(F)` water-blocked cable unless that construction is specified and confirmed.

N2XS2Y can be installed in ground or water-exposed routes when the cable design, zaštita rute i lokalna pravila to dozvoljavaju. Struja i vijek trajanja zavise od dubine ukopavanja, toplotna otpornost tla, razmak, grupisanje, zaštita od vlage i mehaničke zaštite.

Za ponudu projekta, XWA needs the N2XS2Y voltage class, veličina provodnika, bakarni presek ekrana, standard, ruta instalacije, količina, dužina bubnja, odredišnu zemlju i potrebne dokumente za inspekciju ili ispitivanje.

Armored MV Medium Voltage Power Cable

MV kabl za napajanje

Srednjenaponski kablovski sistemi za distribuciju, trafostanice i industrijske napone.

11kV Cable Structure

11kV Cable

Kablovska stranica srednjeg napona za distribuciju 11kV i projektne rasporede kablova.

Studije slučaja XWA & Projekti

    Zatražite besplatnu ponudu 24 Sati

    Email*:

    ime*:

    Vaša zemlja:

    Tel*:

    Vaši zahtjevi*: