2XS(FL)2Y Cable

High Voltage 2XS(FL)2Y Cable

2XS(FL)2Y Cable is a single-core high-voltage power cable with a copper conductor, XLPE 단열재, metallic screen, longitudinal and radial water-blocking layers, and a polyethylene outer sheath.

The designation is used for underground and ducted high-voltage distribution and transmission routes where IEC 60840-type construction, water blocking and PE sheath performance are part of the project specification. Common voltage classes include 26/45 (52) kV, 36/60 (72.5) kV, 64/110 (123) kV and 76/132 (145) kV.

XWA supplies project-configured 2XS(FL)2Y high-voltage cable according to the confirmed voltage class, conductor size, screen section, sheath material, test requirement, drum length and export documentation scope.

2XS(FL)2Y cable

건설

지휘자:

수업 2 stranded copper conductor; watertight conductor option where specified

격리:

XLPE insulation with extruded semiconductive conductor and insulation screens

금속 스크린:

Copper wires with equalising tape and water-swelling tape around the screen area

Radial Barrier:

Longitudinal aluminium copolymer laminated tape bonded to the PE sheath for radial water blocking

형질

Voltage Classes:

26/45 (52) kV, 36/60 (72.5) kV, 64/110 (123) kV and 76/132 (145) kV

외부 칼집:

HDPE or MDPE outer sheath, normally black; semiconductive outer layer by project requirement

설치:

Fixed high-voltage installation in ground, 덕트, trenches, substations and utility network routes

표준:

Common references include IEC 60840 그리고 IEC 60228. Standard reference is not a certification or project approval claim.

2XS(FL)2Y High Voltage Cable for Underground Networks

XWA manufactures high-voltage XLPE cable configurations for utility networks, 변전소, renewable energy grid connections and industrial power systems.

2XS(FL)2Y Cable Technical Data

Recommended Reference Data: 2XS(FL)2Y is normally a single-core high-voltage cable. The table below is a planning reference for copper-conductor 110 kV and 132 kV class designs, not a guaranteed XWA datasheet.

Final cable dimensions, conductor construction, screen section, sheath thickness, induced-voltage design and current-carrying capacity depend on the approved project datasheet, bonding method, route spacing, 매장 깊이, ambient temperature, soil thermal resistivity and installation standard.

Voltage and Size Coverage

Voltage classTypical routeCross-section coveragePlanning note
26/45 (52) kV45 kV class underground HV routes150-3000 mm2 reference rangeIEC 60840 HV cable scope
36/60 (72.5) kV60 kV / 66 kV utility distribution185-3000 mm2 reference rangeOften specified for sub-transmission feeders
64/110 (123) kV110 kV grid and industrial feeders150-3000 mm2 reference rangeCore page intent for 110kV 2XS(FL)2Y
76/132 (145) kV132 kV transmission and substation routes185-3000 mm2 reference rangeCore page intent for 132kV 2XS(FL)2Y

Construction Matrix

LayerTypical materialFunction
지휘자구리, 수업 2 좌초된Optional water-tight conductor when specified
Conductor screenExtruded semiconductive layerApplied as part of the triple-extruded insulation system
격리XLPE90 C normal conductor temperature reference
Insulation screenExtruded semiconductive layerMatched to the insulation system
WrappingSemiconductive water-swelling tapeLongitudinal water blocking around the screen area
Metallic screenCopper wires and equalising tapeScreen section follows fault-current design
Radial barrierAluminium copolymer laminated tapeThe FL element provides radial water-blocking logic
Outer sheathHDPE or MDPEBlack sheath; semiconductive layer optional

Selected 110 kV and 132 kV Reference Rows

Voltage classCable size (mm2)맥스. DC resistance at 20 C (ohm/km)Nominal XLPE insulation (mm)Typical screen section (mm2)Use note
64/110 (123) kV1 엑스 1500.12416.095Typical entry size for 110 kV class
64/110 (123) kV1 엑스 3000.060116.095 또는 120Common 110 kV project size
64/110 (123) kV1 엑스 6300.028316.095 또는 120High-capacity underground feeder
64/110 (123) kV1 엑스 10000.017616.0120High-current route, bonding review required
76/132 (145) kV1 엑스 1850.099116.595 또는 120132 kV entry project range
76/132 (145) kV1 엑스 3000.060116.595 또는 120Common 132 kV project size
76/132 (145) kV1 엑스 6300.028316.595 또는 120High-capacity 132 kV feeder
76/132 (145) kV1 엑스 10000.017616.5120Large-section transmission route

2XS(FL)2Y Cable Construction

2XS(FL)2Y uses a copper conductor with an extruded conductor screen, XLPE insulation and extruded insulation screen. The metallic screen uses copper wires and an equalising tape, with semiconductive water-swelling tape placed around the screen area.

The `(FL)` part is the key distinction from simpler PE-sheathed HV cable. It indicates a water-blocked design with longitudinal water blocking and a radial barrier formed by an aluminium copolymer laminated tape bonded to the polyethylene sheath.

This construction is normally single-core. Three-core high-voltage cable is not treated as the standard form for this designation because electrical stress control, 굽힘 반경, screen bonding and installation handling are different.

Applications for 2XS(FL)2Y High Voltage Cable

2XS(FL)2Y Cable is used in buried high-voltage networks, duct routes, substation connections, renewable-energy grid connections, industrial incoming feeders and utility transmission circuits where PE-sheathed water-blocked HV cable is specified.

The design is especially relevant where moisture exposure, long underground routes, joint bays and sheath integrity are important parts of the cable system. Cable accessories, bonding design and route thermal calculation remain part of the complete HV system design.

For tunnels, indoor termination sections or routes requiring low-smoke zero-halogen sheath behaviour, the related `2XS(FL)H` construction may be reviewed instead of a PE-sheathed `2Y` design.

2XS(FL)2Y vs A2XS(FL)2Y and 2XS(에프)2Y

2XS(FL)2Y and A2XS(FL)2Y share the same high-voltage water-blocked cable logic, but the conductor material is different. 2XS(FL)2Y uses copper, while A2XS(FL)2Y uses aluminium.

2XS(에프)2Y is not the same as 2XS(FL)2Y. The `(에프)` designation is associated with longitudinal water blocking, while `(FL)` adds the laminated radial barrier concept. This difference matters for wet underground routes and sheath-damage risk.

N2XS2Y and N2XSY pages remain medium-voltage designations. The 2XS(FL)2Y page targets high-voltage IEC 60840-type project intent and should not compete with the medium-voltage cluster.

모델Main distinctionPage role
2XS(FL)2Y구리 도체, XLPE, water-blocked screen area, laminated radial barrier, PE sheathThis page
A2XS(FL)2YAluminium conductor versionNext companion HV page
2XS(에프)2YCopper conductor with longitudinal water blocking, without the same FL radial-barrier meaningSeparate water-blocked variant
2XS(FL)시간LSZH outer sheath directionIndoor or low-smoke route comparison

테스트, Documents and Export Packing

High-voltage 2XS(FL)2Y cable documentation can include the approved datasheet, conductor resistance record, voltage test record, partial-discharge test record, 외장 테스트, 치수검사, drum schedule, packing list and product photos.

Type-test evidence, third-party inspection and project-specific test documentation are handled according to the exact voltage class, cable construction and contract requirement. No third-party certification, grid approval or project reference is implied unless separately verified.

Export packing is planned by cable weight, maximum drum diameter, transport route, lifting method and container loading limit. Large-section 110 kV and 132 kV single-core cables require drum-length planning before production.

2XS(FL)2Y Cable FAQs

What is 2XS(FL)2Y Cable?

2XS(FL)2Y Cable is a single-core copper-conductor high-voltage XLPE cable with metallic screen, longitudinal water blocking, laminated radial water barrier and polyethylene outer sheath. It is used for fixed HV underground and ducted cable systems.

Common project voltage classes include 26/45 (52) kV, 36/60 (72.5) kV, 64/110 (123) kV and 76/132 (145) kV. The project specification defines the exact Uo/U and Um rating.

The `(FL)` element indicates water-blocking construction with longitudinal water-blocking layers and a laminated radial barrier bonded to the polyethylene sheath. It is a key distinction from simpler PE-sheathed HV cable.

2XS(FL)2Y is normally a single-core HV cable. Three-core high-voltage designs require a separate review because the construction, accessories, installation handling and electrical design are different.

2XS(FL)2Y uses a copper conductor. A2XS(FL)2Y uses an aluminium conductor. The conductor material changes resistance, 무게, size selection, termination design and short-circuit performance.

2XS(에프)2Y is associated with longitudinal water blocking. 2XS(FL)2Y adds the laminated radial barrier concept, so the two designations should not be treated as interchangeable in wet underground routes.

2XS(FL)2Y is used in underground high-voltage feeders, utility grids, 변전소, renewable-energy grid connections, industrial incoming supplies and ducted transmission routes where water-blocked PE-sheathed HV cable is specified.

IEC 60840 is the common reference for extruded-insulation power cables above 30 kV and up to 150 kV. IEC 60228 is commonly used for conductor class reference. Standard mention does not mean third-party certification or grid approval.

HDPE and MDPE sheath directions are both used in project specifications. The sheath choice depends on route conditions, mechanical exposure, installation handling and the approved datasheet.

XWA confirms 2XS(FL)2Y Cable based on voltage class, conductor size, screen section, sheath material, route condition, 기준, 수량, drum length, destination country and required test documents.