SHD-GC minekabel

XWA Power & Kabel | Gummi kabel modeller

SHD-GC for shielded trailing power for mobile mining plant

Voltage class shown: 5 kV AC (5,000 V)

SHD-GC cable is a shielded mining trailing cable with flexible power cores, grounding conductors and a ground-check conductor. Its screened power-core construction suits equipment connections where voltage control and ground monitoring must work together.

The reference design on this page is a three-power-core, 5 kV konstruktion. Each phase includes the appropriate conductor screen, EPR insulation and flexible metallic shielding arrangement. Different SHD-GC voltage classes have different insulation and dimensional schedules.

SHD-GC mining cable sample with exposed copper conductors and a black outer sheath
SHD-GC mining cable sample.

5 kV reference construction

SHD-GC conductor and layer arrangement

5 kV shielded example cross-section showing 3 screened power cores, 2 grounding conductors, 1 insulated check core, Reinforced jacket
SHD-GC construction schematic.
KomponentKonstruktion
Phase conductorThree flexible rope-lay copper conductors.
Conductor screen and insulationSemiconductive conductor screen followed by EPR insulation.
Insulation shieldingFlexible copper/textile braid shielding around each insulated phase in the reference design.
Grounding and checkTwo grounding conductors plus a separately insulated ground-check core.
Ydre beskyttelseReinforced heavy-duty jacket enclosing the complete assembly.

ICEA S-75-381 / NEMA WC 58 provides the mining-cable construction and test framework. The cited dimensional group is specifically 5 kV, 100% isoleringsniveau, grounded service. Other voltage groups require their own design tables.

SHD-GC reference sizes and technical data

Elektrisk parameterSpecifikation
Nominel spænding5 kV AC (5,000 V)
BedømmelseskonventionSelected 5 kV konstruktion; 100% isoleringsniveau, grounded service
ByggestandardreferenceICEA S-75-381 / NEMA WC 58
KernearrangementThree screened power cores, two grounding conductors and one ground-check conductor.
Power coresGround (AWG)Check (AWG)Isolering (mm)Jakke (mm)AF (mm)Masse (kg/km)Current (EN)
3 × 1/0 AWG482.85.652.34530211
3 × 2/0 AWG382.85.655.15315243
3 × 4/0 AWG182.86.068.87380321

Selected 5 kV reference construction: three power cores, two grounding conductors and one check core; 100% isoleringsniveau, grounded. Reference current values use 90°C conductor and 40°C ambient air under ICEA S-75-381/NEMA WC 58; reel layers and installation conditions require correction.

Shield termination belongs in the machine connection design

Power shovels, draglines and other relocatable mining plant place combined electrical and mechanical demands on their supply cable. The power-core shields, grounding conductors, monitor loop and coupler must remain coordinated when cable is extended, repaired or replaced.

We would treat the coupling arrangement as part of the cable requirement from the outset. A heavier jacket can improve mechanical protection, but it does not address a mismatched shield connection or an unsuitable ground-check termination.

SHD-GC and related rubber cable types

Kabel familieRelevant sondring
Type G-GCGround-check cable with a different power-core screening arrangement; the selected reference is 2 kV.
SHD-GC 5 kVScreened power cores and monitoring conductors for the defined 5 kV duty.
SHD-GC at other voltagesSeparate insulation, skærmen, diameter and coupling requirements; retain the exact voltage class.

For the wider context of SHD-GC applications, udforske række gummikabler, NSSHÖU heavy-duty cable og vores XWA fabriksoplysninger.

SHD-GC cable questions

What distinguishes SHD-GC from G-GC?

SHD-GC adds a shielded power-core construction. Both the shield system and the required voltage class affect dimensions, grounding and termination design.

gør en 5 kV table apply to 8 kV eller 15 kV kabel?

Ingen. Each voltage class requires the corresponding insulation and screen design. The reference dimensions on this page describe only the stated 5 kV konstruktion.

Is the ground-check conductor the same as a grounding conductor?

The check core is used in the monitoring loop. The grounding conductors and the shield-grounding arrangement carry their specified protective duties.

Discuss a SHD-GC cable project with XWA

Send your SHD-GC cable schedule or equipment specification, påkrævet længde og destination til info@xwacable.com. En tegning eller en eksisterende betegnelse er et praktisk udgangspunkt for en produkt- og tilbudssamtale.

Til standardsammenhæng, se officiel teknisk reference.

    Få et gratis tilbud i 24 Timer

    E-mail*:

    Navn*:

    Dit land:

    Tlf*:

    Dine krav*: