SHD-GC Уул уурхайн кабель

XWA хүч & Кабель | Rubber Cable Models

SHD-GC for shielded trailing power for mobile mining plant

Voltage class shown: 5 кВ хувьсах гүйдэл (5,000 В)

SHD-GC cable is a shielded mining trailing cable with flexible power cores, grounding conductors and a ground-check conductor. Its screened power-core construction suits equipment connections where voltage control and ground monitoring must work together.

The reference design on this page is a three-power-core, 5 кВ-ын барилга байгууламж. Each phase includes the appropriate conductor screen, EPR insulation and flexible metallic shielding arrangement. Different SHD-GC voltage classes have different insulation and dimensional schedules.

SHD-GC mining cable sample with exposed copper conductors and a black outer sheath
SHD-GC mining cable sample.

5 kV reference construction

SHD-GC conductor and layer arrangement

5 кВ-ын хамгаалалттай хөндлөн огтлолын жишээг үзүүлэв 3 дэлгэцтэй цахилгааны цөм, 2 газардуулгын дамжуулагч, 1 тусгаарлагдсан шалгах цөм, Хүчитгэсэн хүрэм
SHD-GC construction schematic.
Бүрэлдэхүүн хэсэгБарилга
Фазын дамжуулагчThree flexible rope-lay copper conductors.
Conductor screen and insulationSemiconductive conductor screen followed by EPR insulation.
Insulation shieldingFlexible copper/textile braid shielding around each insulated phase in the reference design.
Grounding and checkTwo grounding conductors plus a separately insulated ground-check core.
Гаднах хамгаалалтReinforced heavy-duty jacket enclosing the complete assembly.

ICEA S-75-381 / Жорлонгүй 58 provides the mining-cable construction and test framework. The cited dimensional group is specifically 5 кВ, 100% тусгаарлагчийн түвшин, grounded service. Other voltage groups require their own design tables.

SHD-GC reference sizes and technical data

Electrical parameterТодорхойлолт
Нэрлэсэн хүчдэл5 кВ хувьсах гүйдэл (5,000 В)
Rating conventionСонгосон 5 кВ-ын барилга байгууламж; 100% тусгаарлагчийн түвшин, grounded service
Construction standard referenceICEA S-75-381 / Жорлонгүй 58
Үндсэн зохион байгуулалтThree screened power cores, two grounding conductors and one ground-check conductor.
Power coresГазар (AWG)Check (AWG)Тусгаарлагч (мм)Jacket (мм)OF (мм)Масс (кг/км)Current (А)
3 × 1/0 AWG482.85.652.34530211
3 × 2/0 AWG382.85.655.15315243
3 × 4/0 AWG182.86.068.87380321

Сонгосон 5 kV reference construction: three power cores, two grounding conductors and one check core; 100% тусгаарлагчийн түвшин, grounded. Reference current values use 90°C conductor and 40°C ambient air under ICEA S-75-381/NEMA WC 58; reel layers and installation conditions require correction.

Shield termination belongs in the machine connection design

Power shovels, draglines and other relocatable mining plant place combined electrical and mechanical demands on their supply cable. The power-core shields, газардуулгын дамжуулагч, monitor loop and coupler must remain coordinated when cable is extended, repaired or replaced.

We would treat the coupling arrangement as part of the cable requirement from the outset. A heavier jacket can improve mechanical protection, but it does not address a mismatched shield connection or an unsuitable ground-check termination.

SHD-GC and related rubber cable types

Cable familyRelevant distinction
Type G-GCGround-check cable with a different power-core screening arrangement; the selected reference is 2 кВ.
SHD-GC 5 кВScreened power cores and monitoring conductors for the defined 5 kV duty.
SHD-GC at other voltagesSeparate insulation, дэлгэц, diameter and coupling requirements; retain the exact voltage class.

For the wider context of SHD-GC applications, судлах rubber cable range, NSSHÖU heavy-duty cable болон манай XWA factory information.

SHD-GC cable questions

What distinguishes SHD-GC from G-GC?

SHD-GC adds a shielded power-core construction. Both the shield system and the required voltage class affect dimensions, grounding and termination design.

Does a 5 kV table apply to 8 кВ эсвэл 15 кВ кабель?

Үгүй. Each voltage class requires the corresponding insulation and screen design. The reference dimensions on this page describe only the stated 5 кВ-ын барилга байгууламж.

Is the ground-check conductor the same as a grounding conductor?

The check core is used in the monitoring loop. The grounding conductors and the shield-grounding arrangement carry their specified protective duties.

Discuss a SHD-GC cable project with XWA

Send your SHD-GC cable schedule or equipment specification, required length and destination to info@xwacable.com. A drawing or an existing designation is a practical starting point for a product and quotation discussion.

For standards context, see the official technical reference.

    Үнэгүй үнийн санал аваарай 24 Цаг

    Имэйл*:

    Нэр*:

    Танай улс:

    Утас*:

    Таны шаардлага*: