Transformer project supply
Pad mounted transformers combine a ground-level transformer with enclosed cable connections for underground distribution networks. The compact arrangement suits industrial sites, commercial developments and utility supply points where the transformer and its terminations need an organised, accessible installation.
The combined construction integrates the transformer with switching and protection functions. Medium- and low-voltage connections are arranged within the selected compartment layout, with the enclosure, base and access space coordinated with the site. Three-phase enquiry examples include 500–2,500 kVA; 12.47 kV / 480Y/277 V is one example of a network-specific voltage configuration.
XWA works with a specialist transformer manufacturing partner to develop the technical and commercial response to project enquiries.

A compact combined transformer arrangement
The transformer tank provides voltage conversion and liquid insulation in an oil-filled design. Incoming switching, fuse protection and cable terminals form the connection to the medium-voltage network. The low-voltage compartment provides the outgoing terminals for the site supply.
In the ZGS combined construction commonly called an American-style box transformer in China, the transformer, load-break switching and fuse functions are integrated around the oil-insulated tank design. A prefabricated substation with separate switchgear and transformer compartments is a different assembly.
Access space is part of the installation
We recommend settling the cable-entry direction and door-opening space before the base is finalised. A compact enclosure saves footprint only when terminations, operating access and maintenance clearances also fit the site.

Electrical configurations for project enquiries
| Parameter | Konfiguration |
|---|---|
| Installation | Ground-level, pad-mounted combined transformer arrangement |
| Phase configuration | Three-phase configurations discussed on this page |
| Capacity examples for enquiry | 500, 750, 1,000, 1,500, 2,000 og 2,500 kVA |
| Voltage configuration | Specified primary / secondary ratio for the destination network |
| Reference voltage examples | 12.47 eller 13.8 kV primary; 480Y/277 V secondary in the North American-style catalogue programme |
| Frequency | Rated frequency matched to the project network |
| Feed arrangement | Radial or loop-feed configuration, with the specified switch arrangement |
| Terminal construction | Dead-front or live-front interface according to the selected design |
| Insulation and cooling | Oil-filled tank and cooling arrangement defined in the technical schedule |
Each project datasheet pairs one selected capacity with its voltage ratio, isoleringsniveau, frekvens, impedance and terminal interface.
A 480Y/277 V secondary identifies a wye-connected system with 480 V line-to-line and approximately 277 V line-to-neutral. The neutral arrangement and earthing requirements form part of the transformer and site design.
Radial and loop-feed connections
Radial feed
A radial arrangement receives power through one incoming feeder. It provides a direct supply path to the transformer, with switching and protection coordinated with the upstream network.
Loop feed
A loop-feed arrangement provides incoming and outgoing feeder ways so several supply points can be connected along a distribution route. The normal open point, switch positions and protection scheme determine how the network operates.
Dead-front and live-front describe the terminal interface, while radial and loop feed describe the feeder arrangement. The two choices address different parts of the specification. A dead-front interface uses screened separable connections; a live-front arrangement has exposed connection points inside the restricted-access compartment.

Ground-level distribution for project sites
| Application | Product value |
|---|---|
| Industrielle anlæg | A compact supply point close to the electrical load with planned cable-entry and service access. |
| Kommerciel udvikling | Enclosed transformer and connection arrangement for underground site distribution. |
| Utility distribution | Radial or loop-feed supply layouts matched to the network operating scheme. |
| Renewable-energy sites | Transformer and terminal configuration matched to the specific project duty and voltage ratio. |
The enclosure, korrosionsbeskyttelse, ambient conditions and drainage around the base influence outdoor service. These details belong in the equipment layout early, particularly where flooding, salt exposure or restricted access affects the site.
Technical documentation and inspection
The transformer specification may call for the relevant IEC 60076 requirements or an ANSI/IEEE design basis, together with local utility requirements. The selected standard, isoleringsniveau, terminal interface and inspection schedule are stated for the actual product.
Complete prefabricated substations have assembly-level requirements in addition to the transformer requirements. Keeping the transformer and complete-assembly specification clear helps align protection, enclosure performance and installation drawings.
Reference: IEC general transformer requirements.
Pad Mounted Transformer FAQs
Is a pad mounted transformer an American-style transformer?
American-style combined transformer is a name commonly used in China for the ZGS arrangement. Pad mounted transformer is the clearer international product term for this type of ground-level unit. The term describes the configuration, not its country of manufacture.
Is every box-type substation a pad-mounted combined transformer?
Box-type substation is a broader term. A prefabricated substation may contain separate medium-voltage switchgear, a transformer and low-voltage equipment in an enclosure. The combined transformer construction integrates these functions differently.
Does loop feed mean both feeders are always energised together?
The operating arrangement depends on switching, interlocking and the designated open point. A loop-feed terminal arrangement provides connection ways; the network design defines the normal and alternative supply states.
What is needed for a pad mounted transformer enquiry?
Send the capacity, primary and secondary voltages, frekvens, phase configuration, quantity and destination. A single-line diagram, required feed arrangement and terminal specification make the initial discussion more precise.
Discuss your transformer project with XWA
Send the capacity, primary and secondary voltages, frekvens, quantity and destination. Include your single-line diagram or technical schedule if available. XWA will discuss the configuration and commercial requirements with our transformer manufacturing partner.
Udforsk power transformer range or use the XWA contact page to start the conversation.