Transmission Grade HV Cable

High Voltage Cable for 66kV to 500kV Grid Projects

XLPE insulated high voltage cable for transmission lines, rozvodny, underground corridors, renewable energy grid connection and grid power systems.

66–500kVHV cable systems
Project-EngineeredConstruction matched to route conditions
Underground & PonorkaRoute-specific cable construction
IEC 60840 / 62067Design and testing framework
High voltage cable category main image for transmission projects
High voltage cable for underground transmission and grid connection projects.

XWA High Voltage Cable

As a high voltage cable manufacturer, XWA supplies 66kV to 500kV XLPE high voltage cables for grid transmission, substation connections and underground power corridors, with copper or aluminum conductors and metallic sheath options matched to project specifications.

XWA’s engineering team develops each HV cable construction according to the voltage class, velikost vodiče, úroveň izolace, metallic sheath system, water-blocking requirements and route conditions for transmission, renewable energy and special installation projects.

Vysokonapěťový kabel is produced for grid transmission, substation connection, renewable energy evacuation, industrial power intake and underground power corridors that require transmission-grade insulated cable systems. XWA supplies HV power cable designs for voltage classes from 66kV to 500kV, with XLPE insulation, copper or aluminum conductors, metallic shielding or sheath systems and water-blocking options for international transmission work.

For each HV cable design, XWA reviews the rated voltage, požadavek na zkrat, vazební uspořádání, prostředí trasy, drum length and project specification before confirming the cable construction and production arrangement.

Transmission Voltage

66kV, 110kV, 132kV, 220kV, 275kV and 500kV designs for grid and utility-level power systems.

Screened XLPE System

Manufactured with conductor screen, XLPE izolace, insulation screen and metallic sheath options for controlled electric stress.

Route-Based Design

Factory configuration covers underground, substation, renewable grid connection, industrial intake and special transmission applications.

HV XLPE Cable Construction

XWA produces XLPE HV cable with a fully screened insulation system to control electric stress. A typical single-core underground high voltage cable includes a compacted copper or aluminum conductor, stínění vodiče, XLPE izolace, izolační clona, metallic screen or metallic sheath, water-blocking layers and an outer sheath suitable for the route environment.

DirigentCopper or aluminum compacted stranded conductor
Insulation SystemObrazovka vodiče, XLPE insulation and bonded insulation screen
Metallic LayerSíto z měděného drátu, corrugated aluminum sheath or lead sheath options
Water BlockingLongitudinal water-blocking and radial water-barrier options
Outer SheathHDPE, MDPE, PVC, LSZH or semiconductive PE where specified
High voltage cable cross section with conductor insulation screen and sheath layers

HV Cable Voltage Range and Technical Data

XWA manufactures high voltage cable for transmission and grid-level power systems from 66kV to 500kV. IEC 60840 is normally used for extruded-insulation power cables above 30kV and up to 150kV, zatímco IEC 62067 is normally used for extruded-insulation power cables above 150kV and up to 500kV. Factory documentation can be prepared around conductor size, úroveň izolace, metallic sheath design, blokování vody, bonding arrangement and routine testing requirements.

Třída napětíCommon Voltage DesignationApplicable StandardProduct Page
66kV36/66(72.5)kVIEC 60840 project specifications66kV kabel
110kV64/110(123)kVIEC 60840 project specifications110kV kabel
132kV76/132(145)kVIEC 60840 project specifications132kV kabel
220kV127/220(245)kVIEC 62067 project specifications220kV kabel
275kV160/275(300)kVIEC 62067 project specifications275kV kabel
500kV290/500(550)kVIEC 62067 project specifications500kV kabel

Manufacturing Reference Ranges

The technical data below summarizes common XWA manufacturing ranges for single-core XLPE high voltage cable by voltage class. Final conductor size, tloušťka izolace, metallic sheath design, diameter and ampacity are confirmed according to the approved cable schedule, installation conditions and applicable project specification.

XWA reviews laying method, tepelný odpor půdy, okolní teplotu, rozteč kabelů, bonding mode and installation depth when preparing ampacity-related technical discussion. The values below are reference ranges for early project comparison.
Třída napětíConductor Size RangeReference Insulation ThicknessPřibl. Overall DiameterReference Ampacity Range
66kV185-1600mm²10.5-13mm55-95mm360-1450A
110kV240-2500mm²16-18mm68-115mm430-1900A
132kV400-2500mm²17-20mm77-117mm485-2005A
220kV630-2500mm²24-27mm103-134mm622-1886A
275kV800-2500mm²27-30mm115-145mm760-2000A
500kV1000-3000mm²34-40mm145-185mm950-2600A
Offshore submarine cable project route for high voltage transmission

Underground, Submarine and Special Transmission Routes

As an international high voltage cable manufacturer, XWA configures underground cable for urban transmission corridors, substation connections, industrial intake lines, renewable energy grid connection and routes where overhead transmission is restricted. Underground cable design considers route length, soil thermal conditions, rozteč kabelů, tahání napětí, joint bay layout, sheath bonding and protection against water ingress.

For submarine HV cable, XWA configures route-specific mechanical protection, pancéřování, water-blocking and installation requirements. See Podmořský kabel a HV Submarine Power/Optical Cable for this application group.

Related Cable Categories

Related cable categories include Podmořský kabel, Horní kabel, MV napájecí kabel, NN napájecí kabel, Kabel ABC, Ovládací kabel a Gumový kabel.

FAQ

What is a high voltage cable?

A high voltage cable is a fully insulated power cable system used for transmission-level voltage. It includes the conductor, polovodivé obrazovky, main insulation, metallic screen or sheath and outer protection layers required to control electric stress and safely transmit power.

What voltage range does XWA high voltage cable cover?

XWA manufactures common high voltage project classes from 66kV to 500kV, including 66kV, 110kV, 132kV, 220kV, 275kV and 500kV cable designs.

Which standards apply to HV XLPE cable?

IEC 60840 is normally used for extruded-insulation power cables above 30kV and up to 150kV. IEC 62067 is normally used for extruded-insulation power cables above 150kV and up to 500kV. Project specifications may also include national grid or utility requirements.

Can HV cable be installed underground?

Ano. Underground high voltage cable is widely used for urban transmission routes, rozvodny, industrial intake lines and renewable energy grid connections. Cable spacing, tepelný odpor půdy, laying depth, bonding mode and route protection affect the final design.

How are higher HV cable classes different?

Higher high voltage cable classes such as 220kV, 275kV and 500kV require more demanding control of insulation thickness, metallic sheath design, příslušenství, testing and installation conditions. XWA treats 220kV as a high voltage transmission cable class.

How does XWA control HV cable production quality?

XWA arranges HV cable production through joint manufacturing with qualified partner factories. XWA confirms the project specification, coordinates conductor preparation, vytlačování izolace, screen and sheath configuration, dimensional checks and routine test records, and controls the agreed documentation and delivery scope.

How does XWA prepare an HV cable quotation?

XWA reviews voltage designation, materiál a velikost vodiče, délka trasy, způsob instalace, metallic sheath or screen requirement, vazební uspořádání, short-circuit level, materiál pláště, drum length and required standard before preparing the cable offer.

Contact XWA for HV Cable Projects

XWA prepares HV cable offers around voltage class, materiál vodiče, délka trasy, způsob instalace, sheath design and required standard, with cable construction matched to the confirmed project specification.

Voltage classes: 66kV to 500kV Konstrukce: XLPE insulated single-core HV cable Aplikace: grid, substation, underground and submarine routes

    Získejte bezplatnou cenovou nabídku 24 hodiny

    E-mail*:

    Jméno*:

    Vaše země:

    tel*:

    Vaše požadavky*: