XWA 220kV Cable | EHV XLPE Cable

Powering Long-Distance Transmission at Scale

NOURRITURE 220câble kV est développé pour la très haute tension (THE) transmission systems, where stability, distance, and load intensity go far beyond conventional grid requirements. Noté à 127/220 kV (Un 245 kV), this cable is designed to serve as a primary transmission artery, enabling efficient bulk power transfer between major substations and across regions. With enhanced insulation structure and optimized electrical design, XWA 220kV EHV cable minimizes dielectric losses while maintaining long-term reliability under continuous high electrical stress.

Années de fabrication
5 +
Pays exportés
40 +
Gamme haute tension
36- 500 kV
Testé en usine XWA
100 %
220Câble kV THT

220Spécifications du câble kV & Construction

- Conducteur: Precision-compacted aluminium or copper conductors (630–2500 mm²) designed to reduce AC resistance and optimize current distribution under high load conditions.
- Isolation: High-performance extruded XLPE (Cross-linked Polyethylene) insulation.
- Customizable Metallic Sheath (Facultatif): Configurable as extruded lead, copper wire screen with aluminum foil barrier, or welded aluminum, based on short-circuit and soil moisture needs.
- Gaine extérieure: Extruded PE (Polyethylene) for robust defense against chemical agents and mechanical wear.
- Rated Voltages: Uo/U 127/220 kV, maximum system voltage Um 245 kV.
- Capacité de fonctionnement: Allant de 0.14 µF/km à 0.27 µF/km en fonction de la taille du conducteur.
- Courant de charge: Allant de 5.6 A/km à 10.8 A/km.

✔ CEI 62067 Conforme -- ✔ Conforme AEIC CS10 -- ✔ ISO 9001 Système qualité -- ✔ Certifié CE -- ✔OEM personnalisé disponible

XWA 220kV Cable Size Datasheet

Structure de câble HT XWA
Type de conducteur Coupe transversale (mm²) Diamètre extérieur (mm) Poids net avec gaine Pb (kg/m)
Aluminium 630 107 18.9
Cuivre 630 103 23.1
Aluminium 1000 108 21.3
Cuivre 1000 111 27.9
Aluminium 1600 123 25.7
Cuivre 1600 127 36.6
Aluminium 2500 130 31.5
Cuivre 2500 134 48.0

Why Choose XWA for 220kV Transmission Projects?

220kV systems operate at a level where design margins are tighter and failure costs are significantly higher. Usine de câbles XWA focuses on engineering reliability into every layer of the cable system.

  • Optimized Electric Field Control
    The insulation and shielding structure is engineered to maintain a uniform electric field, minimizing partial discharge and extending operational lifespan under high electrical stress.
  • Low-Loss Transmission Efficiency
    Carefully selected conductor materials and optimized geometry reduce both resistive and dielectric losses, improving efficiency over long-distance transmission routes.
  • Engineered for Complex Installations
    Suitable for demanding environments such as underground corridors, buried ducts, and utility tunnels where heat dissipation and space constraints are critical factors.
  • 15+ Years Cable Manufacturing Expertise
    With over a decade of specialization in high and extra high voltage cables, XWA has developed deep technical know-how and production stability for large-scale grid projects worldwide.
  • Factory-Direct Pricing Advantage
    As a direct manufacturer, XWA eliminates intermediary costs, offering competitive cable pricing for large infrastructure projects while maintaining strict quality and compliance standards.
  • Complete System Support
    Beyond cable supply, XWA provides integrated solutions including accessories, technical consultation, and installation guidance to ensure seamless project execution.
Usine de câbles XWA

Typical Applications of 220kV Cable

220kV cables are used where high-capacity transmission, long-distance efficiency, and grid reliability are critical.

  • Primary Transmission Corridors
    Carrying bulk power between substations over long distances. The higher voltage reduces current and losses, improving transmission efficiency. Used with prefabricated joints and terminations for stable system connections.
  • Power Plant Evacuation Systems
    Transferring continuous high output from large power plants into the grid. Commonly connected to GIS or AIS substations with matched cable accessories for insulation coordination.
  • Renewable Energy Export
    Linking offshore wind and large solar plants to the grid. Often combined with fiber optic monitoring (ETD) and water-blocked designs for real-time performance and environmental protection.
  • Underground Urban Transmission
    Installed in tunnels, conduits, or direct burial where overhead lines are not feasible. High voltage allows more power transfer within limited space, supported by thermal and bonding system design.
  • Grid Reinforcement Projects
    Increasing capacity of existing networks without new corridors. Typically applied with cross-bonding and surge protection systems to ensure safe and stable operation.
Applications de câbles

Installation & Soutien

Due to their size and operating stress, 220kV cables require precise installation planning:

  • Rayon de courbure: Typically 2.7m – 3.4m, depending on conductor size.
  • Thermal Environment: Installation design must consider soil thermal resistivity and heat dissipation.
  • Handling Requirements: Heavy cable weight demands controlled laying tension and specialized equipment.
  • System Design: Cable spacing and laying formation (trefoil/flat) directly impact current capacity.

Notre équipe d'experts techniques est disponible pour répondre à vos questions, fournir des solutions personnalisées, et accompagnez votre projet de la planification à l'installation.

    Obtenez un devis gratuit en 24 Heures

    E-mail*:

    Nom*:

    Votre pays:

    Tél*:

    Vos exigences*:

    FAQs of XWA 220kV EHV Cable

    Why is 220kV considered extra high voltage?

    UN: Because it operates at a level where insulation design, electric field control, and system reliability require significantly more advanced engineering than lower voltage classes.

    UN: Oui. It is widely used in urban and environmentally sensitive areas, typically installed in ducts, tunnels, or direct burial systems with proper thermal design.

    UN: Under proper design, installation, and operating conditions, XLPE-insulated 220kV cables typically have a durée de vie de 30 à 40 ans ou plus.

    UN: Higher voltage results in stronger electric fields, requiring thicker insulation, more precise shielding design, tighter manufacturing tolerances, and more rigorous testing procedures.

    UN: XWA offers a full EHV range with manufacturing capability up to 500kV, suitable for national grid and large-scale transmission projects.

    UN: Parce que nous sommes le fabricant direct avec plus de 15 années d'expérience en production optimisée, nous éliminons les majorations de tiers et d'intermédiaires. Ce modèle de vente directe à l'acheteur nous permet d'offrir des services hautement compétitifs, une tarification rentable pour les offres d'infrastructures au niveau national tout en respectant strictement les normes de performance et de sécurité de la CEI.

    UN: Oui. Conductor size, sheath type, and structural design can all be tailored to meet specific grid, environmental, and installation requirements.