XWA 220kV Cable | EHV XLPE Cable

Powering Long-Distance Transmission at Scale

YİYECEK 220kV kablosu is developed for extra high voltage (EHV) transmission systems, where stability, distance, and load intensity go far beyond conventional grid requirements. Rated at 127/220 kV (Bir 245 kV), this cable is designed to serve as a primary transmission artery, enabling efficient bulk power transfer between major substations and across regions. With enhanced insulation structure and optimized electrical design, XWA 220kV EHV cable minimizes dielectric losses while maintaining long-term reliability under continuous high electrical stress.

Yıllar İmalatı
5 +
İhraç Edilen Ülkeler
40 +
Yüksek Gerilim Aralığı
36- 500 kV
XWA Fabrikada Test Edilmiştir
100 %
220kV EHV Cable

220kV Kablo Özellikleri & Yapı

- İletken: Precision-compacted aluminium or copper conductors (630–2500 mm²) designed to reduce AC resistance and optimize current distribution under high load conditions.
- Yalıtım: High-performance extruded XLPE (Çapraz bağlı Polietilen) yalıtım.
- Kişiselleştirilebilir Metalik Kılıf (İsteğe bağlı): Ekstrüde kurşun olarak yapılandırılabilir, alüminyum folyo bariyerli bakır tel ekran, veya kaynaklı alüminyum, kısa devre ve toprak nemi ihtiyaçlarına göre.
- Dış Kılıf: Ekstrüde PE (Polietilen) kimyasal maddelere ve mekanik aşınmaya karşı sağlam savunma için.
- Nominal Gerilimler: Uo/U 127/220 kV, maximum system voltage Um 245 kV.
- Çalışma Kapasitesi: Şundan itibaren: 0.14 µF/km'ye 0.27 µF/km iletken boyutuna bağlı olarak.
- Şarj Akımı: Şundan itibaren: 5.6 A/km'ye 10.8 a/km.

✔ IEC 62067 Uyumlu -- ✔ AEIC CS10 Compliant -- ✔ ISO 9001 Kalite Sistemi -- ✔CE Sertifikalı -- ✔Özel OEM Mevcut

XWA 220kV Cable Size Datasheet

XWA HV Kablo Yapısı
İletken Tipi Enine kesit (mm²) Dış Çap (mm) Pb Kılıflı Net Ağırlık (kg/m)
Alüminyum 630 107 18.9
Bakır 630 103 23.1
Alüminyum 1000 108 21.3
Bakır 1000 111 27.9
Alüminyum 1600 123 25.7
Bakır 1600 127 36.6
Alüminyum 2500 130 31.5
Bakır 2500 134 48.0

Why Choose XWA for 220kV Transmission Projects?

220kV systems operate at a level where design margins are tighter and failure costs are significantly higher. XWA Kablo Fabrikası focuses on engineering reliability into every layer of the cable system.

  • Optimized Electric Field Control
    The insulation and shielding structure is engineered to maintain a uniform electric field, minimizing partial discharge and extending operational lifespan under high electrical stress.
  • Low-Loss Transmission Efficiency
    Carefully selected conductor materials and optimized geometry reduce both resistive and dielectric losses, improving efficiency over long-distance transmission routes.
  • Engineered for Complex Installations
    Suitable for demanding environments such as underground corridors, buried ducts, and utility tunnels where heat dissipation and space constraints are critical factors.
  • 15+ Years Cable Manufacturing Expertise
    With over a decade of specialization in high and extra high voltage cables, XWA has developed deep technical know-how and production stability for large-scale grid projects worldwide.
  • Factory-Direct Pricing Advantage
    Doğrudan üretici olarak, XWA eliminates intermediary costs, offering competitive cable pricing for large infrastructure projects while maintaining strict quality and compliance standards.
  • Complete System Support
    Beyond cable supply, XWA provides integrated solutions including accessories, teknik danışmanlık, and installation guidance to ensure seamless project execution.
XWA Kablo Fabrikası

Typical Applications of 220kV Cable

220kV cables are used where high-capacity transmission, long-distance efficiency, and grid reliability are critical.

  • Primary Transmission Corridors
    Carrying bulk power between substations over long distances. The higher voltage reduces current and losses, improving transmission efficiency. Used with prefabricated joints and terminations for stable system connections.
  • Power Plant Evacuation Systems
    Transferring continuous high output from large power plants into the grid. Commonly connected to GIS or AIS substations with matched cable accessories for insulation coordination.
  • Renewable Energy Export
    Linking offshore wind and large solar plants to the grid. Often combined with fiber optic monitoring (DTS) and water-blocked designs for real-time performance and environmental protection.
  • Underground Urban Transmission
    Installed in tunnels, kanallar, or direct burial where overhead lines are not feasible. High voltage allows more power transfer within limited space, supported by thermal and bonding system design.
  • Grid Reinforcement Projects
    Increasing capacity of existing networks without new corridors. Typically applied with cross-bonding and surge protection systems to ensure safe and stable operation.
Kablo Uygulamaları

Kurulum & Destek

Due to their size and operating stress, 220kV cables require precise installation planning:

  • Bükme Yarıçapı: Typically 2.7m – 3.4m, depending on conductor size.
  • Thermal Environment: Installation design must consider soil thermal resistivity and heat dissipation.
  • Handling Requirements: Heavy cable weight demands controlled laying tension and specialized equipment.
  • System Design: Cable spacing and laying formation (trefoil/flat) directly impact current capacity.

Teknik uzmanlardan oluşan ekibimiz sorularınızı yanıtlamak için hazırdır, özel çözümler sunmak, ve projenizi planlamadan kuruluma kadar destekleyin.

    Ücretsiz Fiyat Teklifi Alın 24 Saat

    E-posta*:

    İsim*:

    Ülkeniz:

    Tel*:

    Gereksinimleriniz*:

    FAQs of XWA 220kV EHV Cable

    Why is 220kV considered extra high voltage?

    A: Because it operates at a level where insulation design, electric field control, and system reliability require significantly more advanced engineering than lower voltage classes.

    A: Evet. It is widely used in urban and environmentally sensitive areas, typically installed in ducts, tüneller, or direct burial systems with proper thermal design.

    A: Under proper design, kurulum, and operating conditions, XLPE-insulated 220kV cables typically have a service life of 30–40 years or more.

    A: Higher voltage results in stronger electric fields, requiring thicker insulation, more precise shielding design, tighter manufacturing tolerances, and more rigorous testing procedures.

    A: XWA offers a full EHV range with manufacturing capability up to 500kV, suitable for national grid and large-scale transmission projects.

    A: Çünkü biz doğrudan üreticiyiz 15 yılların optimize edilmiş üretim deneyimi, we eliminate third-party and middleman markups. Bu doğrudan alıcıya modeli, son derece rekabetçi teklifler sunmamızı sağlar, IEC performans ve güvenlik standartlarına sıkı sıkıya bağlı kalarak ulusal düzeydeki altyapı teklifleri için uygun maliyetli fiyatlandırma.

    A: Evet. İletken boyutu, kılıf tipi, and structural design can all be tailored to meet specific grid, environmental, and installation requirements.