Transmission Grade HV Cable

High Voltage Cable for 66kV to 500kV Grid Projects

XLPE insulated high voltage cable for transmission lines, подстанции, underground corridors, renewable energy grid connection and grid power systems.

66–500кВHV cable systems
Project-EngineeredConstruction matched to route conditions
Underground & SubmarineRoute-specific cable construction
МЭК 60840 / 62067Design and testing framework
High voltage cable category main image for transmission projects
High voltage cable for underground transmission and grid connection projects.

XWA Высоковольтный кабель

As a high voltage cable manufacturer, XWA supplies 66kV to 500kV XLPE high voltage cables for grid transmission, substation connections and underground power corridors, with copper or aluminum conductors and metallic sheath options matched to project specifications.

XWA’s engineering team develops each HV cable construction according to the voltage class, размер проводника, insulation level, metallic sheath system, water-blocking requirements and route conditions for transmission, renewable energy and special installation projects.

Кабель высокого напряжения is produced for grid transmission, substation connection, renewable energy evacuation, industrial power intake and underground power corridors that require transmission-grade insulated cable systems. XWA supplies HV power cable designs for voltage classes from 66kV to 500kV, with XLPE insulation, copper or aluminum conductors, metallic shielding or sheath systems and water-blocking options for international transmission work.

For each HV cable design, XWA reviews the rated voltage, short-circuit requirement, bonding arrangement, среда маршрута, drum length and project specification before confirming the cable construction and production arrangement.

Transmission Voltage

66кВ, 110кВ, 132кВ, 220кВ, 275kV and 500kV designs for grid and utility-level power systems.

Screened XLPE System

Manufactured with conductor screen, Изоляция из сшитого полиэтилена, insulation screen and metallic sheath options for controlled electric stress.

Route-Based Design

Factory configuration covers underground, подстанция, renewable grid connection, industrial intake and special transmission applications.

HV XLPE Cable Construction

XWA produces XLPE HV cable with a fully screened insulation system to control electric stress. A typical single-core underground high voltage cable includes a compacted copper or aluminum conductor, экран проводника, Изоляция из сшитого полиэтилена, изоляционный экран, metallic screen or metallic sheath, water-blocking layers and an outer sheath suitable for the route environment.

ДирижерCopper or aluminum compacted stranded conductor
Система изоляцииЭкран проводника, XLPE insulation and bonded insulation screen
Metallic LayerCopper wire screen, corrugated aluminum sheath or lead sheath options
Water BlockingLongitudinal water-blocking and radial water-barrier options
Внешняя оболочкаПНД, MDPE, ПВХ, LSZH or semiconductive PE where specified
High voltage cable cross section with conductor insulation screen and sheath layers

HV Cable Voltage Range and Technical Data

XWA manufactures high voltage cable for transmission and grid-level power systems from 66kV to 500kV. МЭК 60840 is normally used for extruded-insulation power cables above 30kV and up to 150kV, while IEC 62067 is normally used for extruded-insulation power cables above 150kV and up to 500kV. Factory documentation can be prepared around conductor size, insulation level, metallic sheath design, water blocking, bonding arrangement and routine testing requirements.

Класс напряженияCommon Voltage DesignationApplicable StandardProduct Page
66кВ36/66(72.5)кВМЭК 60840 project specifications66кВ кабель
110кВ64/110(123)кВМЭК 60840 project specifications110кВ кабель
132кВ76/132(145)кВМЭК 60840 project specifications132кВ кабель
220кВ127/220(245)кВМЭК 62067 project specifications220кВ кабель
275кВ160/275(300)кВМЭК 62067 project specifications275кВ кабель
500кВ290/500(550)кВМЭК 62067 project specifications500кВ кабель

Производственные эталонные диапазоны

The technical data below summarizes common XWA manufacturing ranges for single-core XLPE high voltage cable by voltage class. Final conductor size, толщина изоляции, metallic sheath design, diameter and ampacity are confirmed according to the approved cable schedule, installation conditions and applicable project specification.

XWA reviews laying method, термическое сопротивление почвы, температура окружающей среды, расстояние между кабелями, bonding mode and installation depth when preparing ampacity-related technical discussion. The values below are reference ranges for early project comparison.
Класс напряженияConductor Size RangeReference Insulation ThicknessПриблизительно. Общий диаметрReference Ampacity Range
66кВ185-1600мм²10.5-13мм55-95мм360-1450А
110кВ240-2500мм²16-18мм68-115мм430-1900А
132кВ400-2500мм²17-20мм77-117мм485-2005А
220кВ630-2500мм²24-27мм103-134мм622-1886А
275кВ800-2500мм²27-30мм115-145мм760-2000А
500кВ1000-3000мм²34-40мм145-185мм950-2600А
Offshore submarine cable project route for high voltage transmission

Underground, Submarine and Special Transmission Routes

As an international high voltage cable manufacturer, XWA configures underground cable for urban transmission corridors, подключение подстанции, industrial intake lines, renewable energy grid connection and routes where overhead transmission is restricted. Underground cable design considers route length, soil thermal conditions, расстояние между кабелями, напряжение, joint bay layout, sheath bonding and protection against water ingress.

For submarine HV cable, XWA configures route-specific mechanical protection, броня, water-blocking and installation requirements. See Подводный кабель и HV Submarine Power/Optical Cable for this application group.

Related Cable Categories

Related cable categories include Подводный кабель, Воздушный кабель, Силовой кабель среднего напряжения, Силовой кабель низкого напряжения, Кабель ABC, Кабель управления и Резиновый кабель.

Часто задаваемые вопросы

What is a high voltage cable?

A high voltage cable is a fully insulated power cable system used for transmission-level voltage. It includes the conductor, semiconductive screens, main insulation, metallic screen or sheath and outer protection layers required to control electric stress and safely transmit power.

What voltage range does XWA high voltage cable cover?

XWA manufactures common high voltage project classes from 66kV to 500kV, including 66kV, 110кВ, 132кВ, 220кВ, 275kV and 500kV cable designs.

Which standards apply to HV XLPE cable?

МЭК 60840 is normally used for extruded-insulation power cables above 30kV and up to 150kV. МЭК 62067 is normally used for extruded-insulation power cables above 150kV and up to 500kV. Project specifications may also include national grid or utility requirements.

Can HV cable be installed underground?

Да. Underground high voltage cable is widely used for urban transmission routes, подстанции, industrial intake lines and renewable energy grid connections. Cable spacing, термическое сопротивление почвы, laying depth, bonding mode and route protection affect the final design.

How are higher HV cable classes different?

Higher high voltage cable classes such as 220kV, 275kV and 500kV require more demanding control of insulation thickness, metallic sheath design, аксессуары, testing and installation conditions. XWA treats 220kV as a high voltage transmission cable class.

How does XWA control HV cable production quality?

XWA arranges HV cable production through joint manufacturing with qualified partner factories. XWA confirms the project specification, coordinates conductor preparation, insulation extrusion, screen and sheath configuration, dimensional checks and routine test records, and controls the agreed documentation and delivery scope.

How does XWA prepare an HV cable quotation?

XWA reviews voltage designation, conductor material and size, длина маршрута, метод установки, metallic sheath or screen requirement, bonding arrangement, short-circuit level, материал оболочки, drum length and required standard before preparing the cable offer.

Свяжитесь с XWA для проектов по прокладке высоковольтных кабелей

XWA prepares HV cable offers around voltage class, материал проводника, длина маршрута, метод установки, sheath design and required standard, with cable construction matched to the confirmed project specification.

Voltage classes: 66kV to 500kV Строительство: XLPE insulated single-core HV cable Приложения: grid, подстанция, underground and submarine routes

    Получите бесплатное предложение в 24 Часы

    Электронная почта*:

    Имя*:

    Ваша страна:

    Тел*:

    Ваши требования*: