High Voltage Cable for 66kV to 500kV Grid Projects
XLPE insulated high voltage cable for transmission lines, подстанции, underground corridors, renewable energy grid connection and grid power systems.
XWA Высоковольтный кабель
As a high voltage cable manufacturer, XWA supplies 66kV to 500kV XLPE high voltage cables for grid transmission, substation connections and underground power corridors, with copper or aluminum conductors and metallic sheath options matched to project specifications.
XWA’s engineering team develops each HV cable construction according to the voltage class, размер проводника, insulation level, metallic sheath system, water-blocking requirements and route conditions for transmission, renewable energy and special installation projects.
HV Cable Product Selection
XWA organizes HV cable production by voltage class, conductor system, sheath design and route condition, so each product page reflects a practical manufacturing and specification range.






Кабель высокого напряжения is produced for grid transmission, substation connection, renewable energy evacuation, industrial power intake and underground power corridors that require transmission-grade insulated cable systems. XWA supplies HV power cable designs for voltage classes from 66kV to 500kV, with XLPE insulation, copper or aluminum conductors, metallic shielding or sheath systems and water-blocking options for international transmission work.
For each HV cable design, XWA reviews the rated voltage, short-circuit requirement, bonding arrangement, среда маршрута, drum length and project specification before confirming the cable construction and production arrangement.
Transmission Voltage
66кВ, 110кВ, 132кВ, 220кВ, 275kV and 500kV designs for grid and utility-level power systems.
Screened XLPE System
Manufactured with conductor screen, Изоляция из сшитого полиэтилена, insulation screen and metallic sheath options for controlled electric stress.
Route-Based Design
Factory configuration covers underground, подстанция, renewable grid connection, industrial intake and special transmission applications.
HV XLPE Cable Construction
XWA produces XLPE HV cable with a fully screened insulation system to control electric stress. A typical single-core underground high voltage cable includes a compacted copper or aluminum conductor, экран проводника, Изоляция из сшитого полиэтилена, изоляционный экран, metallic screen or metallic sheath, water-blocking layers and an outer sheath suitable for the route environment.
| Дирижер | Copper or aluminum compacted stranded conductor |
| Система изоляции | Экран проводника, XLPE insulation and bonded insulation screen |
| Metallic Layer | Copper wire screen, corrugated aluminum sheath or lead sheath options |
| Water Blocking | Longitudinal water-blocking and radial water-barrier options |
| Внешняя оболочка | ПНД, MDPE, ПВХ, LSZH or semiconductive PE where specified |

HV Cable Voltage Range and Technical Data
XWA manufactures high voltage cable for transmission and grid-level power systems from 66kV to 500kV. МЭК 60840 is normally used for extruded-insulation power cables above 30kV and up to 150kV, while IEC 62067 is normally used for extruded-insulation power cables above 150kV and up to 500kV. Factory documentation can be prepared around conductor size, insulation level, metallic sheath design, water blocking, bonding arrangement and routine testing requirements.
| Класс напряжения | Common Voltage Designation | Applicable Standard | Product Page |
|---|---|---|---|
| 66кВ | 36/66(72.5)кВ | МЭК 60840 project specifications | 66кВ кабель |
| 110кВ | 64/110(123)кВ | МЭК 60840 project specifications | 110кВ кабель |
| 132кВ | 76/132(145)кВ | МЭК 60840 project specifications | 132кВ кабель |
| 220кВ | 127/220(245)кВ | МЭК 62067 project specifications | 220кВ кабель |
| 275кВ | 160/275(300)кВ | МЭК 62067 project specifications | 275кВ кабель |
| 500кВ | 290/500(550)кВ | МЭК 62067 project specifications | 500кВ кабель |
Производственные эталонные диапазоны
The technical data below summarizes common XWA manufacturing ranges for single-core XLPE high voltage cable by voltage class. Final conductor size, толщина изоляции, metallic sheath design, diameter and ampacity are confirmed according to the approved cable schedule, installation conditions and applicable project specification.
| Класс напряжения | Conductor Size Range | Reference Insulation Thickness | Приблизительно. Общий диаметр | Reference Ampacity Range |
|---|---|---|---|---|
| 66кВ | 185-1600мм² | 10.5-13мм | 55-95мм | 360-1450А |
| 110кВ | 240-2500мм² | 16-18мм | 68-115мм | 430-1900А |
| 132кВ | 400-2500мм² | 17-20мм | 77-117мм | 485-2005А |
| 220кВ | 630-2500мм² | 24-27мм | 103-134мм | 622-1886А |
| 275кВ | 800-2500мм² | 27-30мм | 115-145мм | 760-2000А |
| 500кВ | 1000-3000мм² | 34-40мм | 145-185мм | 950-2600А |

Underground, Submarine and Special Transmission Routes
As an international high voltage cable manufacturer, XWA configures underground cable for urban transmission corridors, подключение подстанции, industrial intake lines, renewable energy grid connection and routes where overhead transmission is restricted. Underground cable design considers route length, soil thermal conditions, расстояние между кабелями, напряжение, joint bay layout, sheath bonding and protection against water ingress.
For submarine HV cable, XWA configures route-specific mechanical protection, броня, water-blocking and installation requirements. See Подводный кабель и HV Submarine Power/Optical Cable for this application group.
Related Cable Categories
Related cable categories include Подводный кабель, Воздушный кабель, Силовой кабель среднего напряжения, Силовой кабель низкого напряжения, Кабель ABC, Кабель управления и Резиновый кабель.
Часто задаваемые вопросы
What is a high voltage cable?
A high voltage cable is a fully insulated power cable system used for transmission-level voltage. It includes the conductor, semiconductive screens, main insulation, metallic screen or sheath and outer protection layers required to control electric stress and safely transmit power.
What voltage range does XWA high voltage cable cover?
XWA manufactures common high voltage project classes from 66kV to 500kV, including 66kV, 110кВ, 132кВ, 220кВ, 275kV and 500kV cable designs.
Which standards apply to HV XLPE cable?
МЭК 60840 is normally used for extruded-insulation power cables above 30kV and up to 150kV. МЭК 62067 is normally used for extruded-insulation power cables above 150kV and up to 500kV. Project specifications may also include national grid or utility requirements.
Can HV cable be installed underground?
Да. Underground high voltage cable is widely used for urban transmission routes, подстанции, industrial intake lines and renewable energy grid connections. Cable spacing, термическое сопротивление почвы, laying depth, bonding mode and route protection affect the final design.
How are higher HV cable classes different?
Higher high voltage cable classes such as 220kV, 275kV and 500kV require more demanding control of insulation thickness, metallic sheath design, аксессуары, testing and installation conditions. XWA treats 220kV as a high voltage transmission cable class.
How does XWA control HV cable production quality?
XWA arranges HV cable production through joint manufacturing with qualified partner factories. XWA confirms the project specification, coordinates conductor preparation, insulation extrusion, screen and sheath configuration, dimensional checks and routine test records, and controls the agreed documentation and delivery scope.
How does XWA prepare an HV cable quotation?
XWA reviews voltage designation, conductor material and size, длина маршрута, метод установки, metallic sheath or screen requirement, bonding arrangement, short-circuit level, материал оболочки, drum length and required standard before preparing the cable offer.
Свяжитесь с XWA для проектов по прокладке высоковольтных кабелей
XWA prepares HV cable offers around voltage class, материал проводника, длина маршрута, метод установки, sheath design and required standard, with cable construction matched to the confirmed project specification.