35kV Medium-High Voltage Cable

35kV Cable – Key Specifications & 工事
- 導体:高純度の軟銅またはアルミニウム導体, available in various cross-sections (50mm² to 800mm²).
- 絶縁:XLPE (架橋ポリエチレン) or HEPR (Hard Ethylene Propylene Rubber) insulation, offering excellent thermal stability, high dielectric strength, and long-term aging resistance for 35kV high-voltage systems.
- スクリーン/シース:Triple-layer semi-conductive and metallic copper screen to precisely control electric fields and eliminate partial discharges; アウターシース (PVC, PE, or halogen-free LSZH compound) provides robust protection against oils, 化学薬品, UV radiation, および機械的損傷.
- 装甲:Optional galvanized steel wire armor (SWA) or steel tape armor (STA) for enhanced mechanical protection against crushing, インパクト, rodent damage, and tensile stress in heavy-duty installation scenarios.
- 定格電圧:35kV (26/35kV, 21/35kV, 18/30kV(36kV))
- 規格への準拠:IEC 60502-2, IEC 60228, IEC/EN 60332-1-2, ギガバイト/トン 12706, ギガバイト/トン 11017
Technical Specifications of XWA 35kV Cable
| アイテム | パラメータ | 詳細 |
|---|---|---|
| 導体 | 材料 | High-purity annealed 銅 (銅) / アルミニウム (アル) |
| 標準 | IEC 60228 (クラス 2/5) | |
| 断面 | 50 mm² ~ 800 mm² (Customizable) | |
| 絶縁 | 材料 | XLPE (Cross-linked PE) / HEPR (Hard EPR) |
| 厚さ | ≥ 10.0 mm (IECによる 60502-2 for 26/35kV) | |
| Temp. Rating | 90℃ (継続的な); 130℃ (short-term) | |
| Dielectric Strength | ≥ 30 kV/mm (DC) | ≥ 20 kV/mm (AC) | |
| Volume Resistivity | ≥ 1×10¹⁴ Ω·m (20℃) | |
| 画面 | Inner Screen | Semi-conductive XLPE compound (thickness ≥ 1.5 mm) |
| メタリックスクリーン | 銅テープ (≥ 0.20 mm) / Copper strands (Mandatory) | |
| Outer Screen | Semi-conductive PE sheath (thickness ≥ 1.5 mm) | |
| Grounding Resistance | ≤ 0.3 Ω/km (20℃) | |
| 装甲 | タイプ | SWA (スチールワイヤー) / STA (Steel Tape) (オプション) |
| アウターシース | 材料 | PVC / PE / LSZH (Halogen-free) |
| パフォーマンス | 曲げ半径 | ≥ 20D (Armored) / ≥ 15D (Unarmored) |
| 規格 | コンプライアンス | IEC 60502-2, ギガバイト/トン 12706, ギガバイト/トン 11017, CE, ISO 9001 |
Applications of XWA 35kV Cable
- Industrial Power Distribution: Reliable power supply for heavy machinery, manufacturing lines, 処理装置, and factory automation systems, ensuring stable operation in demanding industrial environments.
- 採掘作業: Robust armored construction withstands harsh terrain, vibration, and potential mechanical damage, making it ideal for surface and underground mining power networks.
- Infrastructure & Public Utilities: Used in tunnels, 空港, 水処理プラント, transportation hubs, and urban grid upgrades to power pumps, 点灯, and critical public services.
- Renewable Energy Projects: Connects wind turbine generators, 太陽光発電用インバーター, およびエネルギー貯蔵システムを主電力網に接続, supporting large-scale clean energy infrastructure worldwide.
- コマーシャル & High-Rise Buildings: Serves as the main distribution feeder for large commercial complexes, 病院, データセンター, and high-rise office buildings.
- Utility & Power Grids: Primary and secondary power distribution for municipal and industrial utility grids, including overhead, 直葬, and duct installations.
- Oil & Gas Projects: Reliable power transmission for offshore platforms, onshore processing facilities, and remote oilfield operations, with resistance to chemical corrosion and extreme weather.
- Railway & 交通機関: Supplies stable power to high-speed rail, subway systems, and airport infrastructure, ensuring uninterrupted operation of transportation networks.
FAQs of 10kV Cable
What is the rated voltage of XWA 35kV cable, and what does U0/U 26/35kV mean?
- U0 (26kV): The maximum voltage that the cable insulation can withstand between the conductor and the earth (or metallic screen) during long-term operation.
- U (35kV): The maximum voltage between any two conductors of the cable during long-term operation.This voltage grade is specifically designed for 35kV high-voltage power transmission and distribution networks, ensuring safe and stable operation under high electric field stress.
What are the key installation requirements for XWA 35kV cable, especially for direct burial?
- Minimum bending radius: ≥ 20D (armored) or ≥ 15D (unarmored), where D is the cable outer diameter (stricter than 10kV cables to protect the thicker insulation).
- Burial depth: ≥ 1.0 meters (1.2 meters in traffic areas) to avoid mechanical damage and external stress.
- Protection layer: Sand cushion (≥ 100mm) and concrete/brick cover must be laid above the cable to prevent crushing.
- Avoidance: Keep away from chemical corrosion sources, high-temperature pipelines, and sharp objects to extend service life.
What is the design service life of XWA 35kV cable, and what factors affect it most?
- Operating temperature: Long-term operation above 90°C will accelerate XLPE insulation aging.
- Partial discharge: Poor manufacturing or installation can cause partial discharges, which gradually degrade the insulation.
- Environmental stress: UV radiation, 化学腐食, and soil moisture will reduce insulation performance over time.
- Overload faults: Frequent short-circuit or overload events will damage the insulation and metallic screen.
Can XWA 35kV cable be customized for special project needs?
- 導体: High-purity copper or aluminum, cross-sections from 50mm² to 800mm².
- 絶縁 & sheath: XLPE/HEPR insulation, with PVC/PE/LSZH (halogen-free) sheath options.
- 装甲: SWA (steel wire armor) or STA (steel tape armor) for enhanced mechanical protection.
- Special features: Water-blocking layers, fire-resistant structures, or custom lengths (supplied on steel drums for long lengths).
What other medium voltage cables do you provide?
In addition to 35kV cable, we also supply 6kV MV cables, 10kV MV Cables, and other medium voltage cables based on project requirements.