XWA 132kV Cable | كابل الجهد العالي

Powering the Core of the Grid

طعام 132كابل كيلو فولت provides the critical link between major generation facilities and primary distribution networks. Built with advanced XLPE insulation , these single-core power cables (rated 76/132 كيلو فولت, واحد 145 كيلو فولت) are specifically engineered to handle massive electrical loads over extended routes with minimal line loss. From deep-underground city circuits to heavy industrial complexes, XWA provides a fully integrated, type-tested solution that meets the highest international safety and performance standards.

سنوات التصنيع
5 +
الدول المصدرة
40 +
نطاق الجهد العالي
36- 500 كيلو فولت
تم اختباره في مصنع XWA
100 %
132كابل الجهد العالي كيلو فولت

132مواصفات كابل كيلو فولت & بناء

- موصل: موصلات من الألومنيوم والنحاس عالية النقاء. تتراوح مساحات المقطع العرضي من 400 mm² up to a massive 2500 mm² to handle extreme loads.
- العزل: مقذوف XLPE (البولي إيثيلين المتقاطع) العزل.
- غمد معدني قابل للتخصيص (خياري): شكلي كما مقذوف الرصاص, copper wire screen with aluminum foil barrier, or welded aluminum, based on short-circuit and soil moisture needs.
- الغلاف الخارجي: مقذوف PE (البولي ايثيلين) for robust defense against chemical agents and mechanical wear.
- الفولتية المقدرة: يو / يو 76/132 كيلو فولت.
- سعة التشغيل: تتراوح من 0.16 μF/كم إلى 0.32 μF/كم حسب حجم الموصل.
- تيار الشحن: تتراوح من 3.8 ألف/كم إلى 7.6 ألف/كم.

✔ اللجنة الانتخابية المستقلة 60840 متوافق -- ✔ متوافق مع AEIC CS9 -- ✔ ايزو 9001 نظام الجودة -- ✔ حاصلة على شهادة CE -- ✔ تصنيع المعدات الأصلية المخصصة المتاحة

XWA 132kV Cable Size Datasheet

هيكل كابل XWA HV
نوع الموصل المقطع العرضي (مم²) القطر الخارجي (مم) الوزن الصافي مع غمد Pb (كجم/م)
الألومنيوم 400 77 11.4
نحاس 400 77 14.0
الألومنيوم 1000 84 15.9
نحاس 1000 95 22.5
الألومنيوم 2500 117 20.9
نحاس 2500 117 37.4

Why Choose XWA 132kV Power Cable?

Sourcing cable for 132kV networks requires absolute confidence in your manufacturing partner. XWA cable manufacturer delivers uncompromising quality engineered specifically for the extreme demands of primary bulk power transmission, ensuring grid stability under the most punishing loads.

  • Proven Global Track Record: Entrust your critical infrastructure to a manufacturer with over 15 years of specialized high-voltage expertise. Having successfully supplied mega-projects across more than 60 countries, our engineering team possesses the operational maturity to execute complex, large-scale grid requirements flawlessly.
  • Optimized, Factory-Direct Economics: Mega-scale grid projects require strict budget controls. By owning and operating our own advanced manufacturing facilities, we bypass third-party markups. This allows us to offer highly competitive, cost-effective pricing on 132kV cables—empowering you to win major infrastructure bids without sacrificing international compliance or material integrity.
  • Unwavering Thermal Stability: Engineered to manage massive energy loads, our advanced XLPE insulation supports a continuous inner conductor operating temperature of 90°C. During severe grid faults, the conductor is designed to safely endure short-circuit temperature spikes up to 250°C.
  • Project-Specific Sheath Engineering: Because fault currents and soil conditions vary wildly across national grids, we custom-engineer your cable’s protective layers. Choose from an extruded lead alloy, a robust aluminium welded sheath, or a copper wire helix configuration to perfectly counter your project’s specific thermal and dynamic short-circuit stresses.
مصنع كابلات XWA

Applications of XWA 132kV High Voltage Cable

XWA 132kV high voltage power cables are built to handle massive continuous current loads across extended distances, making them the optimal choice for large-scale transmission projects:

  • National Grid Interconnects: Serving as the critical, high-capacity link transferring bulk energy from major power generation plants directly to regional step-down distribution substations.
  • Urban Metropolitan Networks: Safely routing massive power reserves beneath densely populated cities where overhead transmission lines are restricted or physically impossible, utilizing secure direct ground burial.
  • Mega-Scale Renewable Export: Acting as the primary transmission arteries for massive offshore wind farms and utility-scale solar arrays, efficiently moving bulk green energy to the main grid.
  • Heavy Industrial & Smelting Plants: Delivering uninterrupted, high-capacity power to energy-intensive facilities like steel mills, petrochemical refineries, and mining operations. These can be safely routed through heavy-duty buried ducts to protect against surface traffic.
  • Overhead Line Transitions: Providing safe and seamless transitions from long-distance overhead transmission lines into heavily fortified, naturally ventilated overground utility tunnels or air installations.
تطبيقات الكابلات

تثبيت & يدعم

To maximize the lifespan and safety of your XWA 132kV transmission lines, professional installation and strict adherence to technical guidelines are required:

  • الحد الأدنى لنصف قطر الانحناء: Strict adherence to the bending radius during dynamic cable laying is critical, ranging from 1.9m to 2.9m depending on the specific conductor and cross-section.
  • Temperature Constraints: The minimum cable temperature during laying must not fall below -10°C for cables with a PE outer sheath; at lower temperatures, cables must be adequately warmed beforehand.
  • System Integration: XWA delivers a complete system supply, ensuring our cables and accessories are type-tested together for flawless integration.

فريقنا من الخبراء الفنيين متاح للإجابة على أسئلتك, تقديم حلول مخصصة, ودعم مشروعك من التخطيط إلى التثبيت.

    احصل على عرض أسعار مجاني في 24 ساعات

    بريد إلكتروني*:

    اسم*:

    بلدك:

    الهاتف*:

    متطلباتك*:

    FAQs of XWA 132kV Cable

    What applications are the 132kV cable generally used in?

    أ: Our 132kV XLPE cables are designed for bulk power transmission. They are primarily utilized as the main interconnects between major power generation plants and regional step-down substations, for integrating mega-scale renewable energy farms into the national grid, and for supplying uninterrupted power to energy-intensive heavy industrial plants.

    أ: At the 132kV transmission level, real-time monitoring is critical. Fiber optic cables are frequently laid alongside or integrated into the high-voltage cable system for Distributed Temperature Sensing (دتس). This allows grid operators to constantly monitor the cable’s thermal performance across its entire length, optimize the continuous current-carrying capacity, and instantly pinpoint thermal bottlenecks or faults before they cause outages.

    أ: While both are high-capacity XLPE-insulated cables, they serve different grid tiers based on their voltage ratings. The 110kV power cable has a maximum operating voltage of 123 كيلو فولت, typically used for regional sub-transmission. The 132kV cable handles a higher maximum operating voltage of 145 kV for primary bulk power transmission.

    أ: لأننا الشركة المصنعة المباشرة مع أكثر من ذلك 15 سنوات من الخبرة في الإنتاج الأمثل, we now eliminate third-party and middleman markups. يتيح لنا نموذج البيع المباشر للمشتري هذا تقديم خدمات تنافسية للغاية, تسعير فعال من حيث التكلفة لعطاءات البنية التحتية على المستوى الوطني مع الالتزام الصارم بمعايير الأداء والسلامة الخاصة بـ IEC.

    أ: نعم. The 132kV cable is built to handle massive thermal and dynamic short-circuit stresses. The advanced XLPE insulation can safely withstand short-circuit temperatures up to 250°C. To manage the specific short-circuit currents of your grid, we customize the metallic sheath layer using options like extruded lead, a copper wire screen, أو الألومنيوم الملحومة.

    أ: Because 132kV cables carry massive loads, they feature thick XLPE insulation and large conductor cross-sections (ما يصل الى 2500 مم²). Consequently, their minimum bending radius during dynamic laying ranges from 1.9m up to 2.9m. Engineers must strictly account for these dimensions when designing underground trenches, turning radii in utility tunnels, or buried ducts to prevent mechanical damage to the cable.